Tender Value
₹2.3 L
EMD Value
₹4,594
Closing Date
30 Sept 2026, 3:30 pm3d left
Executive Engineer
IWD IIT Kanpur
SITC of flood light in volley ball, badminton and basket ball court and surface light in front of Hall office in Hall 13 and elsewhere in IIT Kanpur
2026_IITK_927644_1
65/EE/Elect/2026-27
Open Tender
Electrical Works
Percentage
60 days
IIT Kanpur
As per tender
3 documents required · 3 mandatory
₹0
₹4,594
24 Sept 2026
24 Sept 2026
1 Oct 2026
24 Sept 2026
30 Sept 2026
24 Sept 2026
24 Sept 2026 - 28 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd. | |||||
| 1.1 | 3 x 1.5 Sq.mm.. | 10 | Mtr. | 103 | ₹1,030 |
| 2LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt): Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) | |||||
| 2.1 | 40 watt | 9 | Nos. | 2,502 | ₹22,518 |
| 3LED Flood Light, powder coated pressure die cast aluminium (System umen efficacy >135lm/Watt): Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 3.1 | 250 watt | 16 | Nos. | 6,167 | ₹98,672 |
| 4Supply, fixing, connecting and commissioning the add on block for contactor (MNX - 9-80// MCX 01-23) of following ratings including connection etc. as reqd. | |||||
| 4.1 | 1 NO + 1 NC | 2 | Nos. | 493 | ₹986 |
| 5Supply,fixing, connecting and commissioning power contactor of following ratings and 3 pole (magnetic release) including providing connection etc. as req | |||||
| 5.1 | MNX-32, 230/415 V,50 Hz | 1 | Nos. | 3,286 | ₹3,286 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
Tendernotice_2.pdf
PDF • 1.34 MB
BOQ_974837.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .