Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance ADD 627 BAKSHI KHURD DARAGANJ TEHSIL SADAR PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical All Technical Specification not full field |
Tender Value
₹8.7 L
EMD Value
₹8,000
Closing Date
16 Mar 2021, 2:00 pmClosed
S.E EUCC-(V) LESA CIS-GOMTI
LESA Bhawan Near Residency Kaiserbagh Lucknow-226018
Shifting of 33 kv, 11 kv and LT line passing over the new proposed road between Hardoi bypass Road to Kanausi Colony
2021_MVVNL_567308_1
34/EUCC(V)/LESA/2020-21
Open Tender
Electrical Works
180 days
Hardoi bypass Road to Kanausi Colony
As per Tender Document
2 documents required · 2 mandatory
₹1,180
A/c. No.10101985364, IFSC CODE No.SBIN0003347,SBI
₹8,000
25 Mar 2021
10 Mar 2021
16 Mar 2021
10 Mar 2021
16 Mar 2021
10 Mar 2021
Amount
Safe Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dump store and JE dump store to work site within municipal areas.
33 KV 3x300sqmm XLPE Cable
33 KV Jointing Kit 3x300 sq mm Cable Outdoor
11 KV 3x185 sqmm XLPE Cable
11 KV Jointing Kit 3x185 sq mm Straight Through
11 KV Jointing Kit 3x185 sq mm O/D
LT PVC Cable 3.5x240 sqmm
ST-Pole 9 mtr. long
ST-Pole 11 mtr. long
MS-Earthing Rod 20x1800 mm
LT- Distribution Box 03 Phase
LT- Distribution Box Clamp
11KV Disc Insulator B &S. Type 7000 Kg
11 kv Disc Insulator T&C 45 KN
Top chanel 125X65MM
M.S. Angle Iron 65x65x6mm (cable dropper+Bracing)
Disc Fittings Dog/Racoon 7000 Kg
Stay rod 20x1800mm Complete Sst
Stay Wire 7/8 SWG
M.S.Channel 100x50 sq mm
Stay Rod 16x1800 mm Complete set
Stay wire 7/10 SWG
Disc fitting T&C Type 45 KN
Digging of pit in Kachcha/Pakka land in depth upto 1/6 length of pole, Dragging of STP from nearby place/dump, Erection of single pole along with stone pad in bottom with proper alignment on 09/11 mtr long ST pole and refilling with ramming of earth
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement, sand and brick ballast as per RESPO norms.
Construction of pole plinth 300 mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of new erected ST pole with two coat of Red oxide paint, PO red paint at top of pole 2 mtr and balance by two coats of best quality aluminium paint ISI of Berger/Nerolac/Asian paints as per norms.
Fabrication & erection of End type double pole for 33 KV line on 11 mtr. long ST-Pole with fixing of necessary clamps & other accesories like 02 No. Top channel 125x65mm (1600 mm each) , 02 No. Bracing angle 65x65x6x4300 mm, Cable dropper, Disc Insulator with fitting, Danger board, Number plates and Barbed wire etc. (All required materials will be provided by contractor except ST- pole, Top channel, Bracing angle, cable dropper, Disc Insulator & Disc fitting)
Laying of D/C 33 KV 3x300 Sqmm XLPE cable in parallel in normal soil by digging of trench 1050 mm deep & 750 mm wide its boxing with bricks laying of cable & seperation of cable by brick wall, filling of sand upto top and covering with stone slab after laying of cable (All material will be provided by contractor except 33 KV cable)
Laying of 33 KV XLPE cable 3x300 sq mm S/C in GI- Pipe 150 mm dia by digging of trench in Kachcha/Pakka of suitable size at road crossing (All material will be provided by contractor except 33 KV cable)
Hoisting of 33 KV 3x300 Sqmm XLPE cable on D/P through GI- pipe of size 6" dia 3 mtr long including its jumpering complete with holding clamps, PG clamps, Nut & bolts (All material will be provided by contractor)
Erection of stay set 20x1800 mm by digging of pit of size 0.4x0.6x1.6 mtr including grouting, binding, nuzzling and fixing of stay insulator with stay wire of size 7/10 SWG (All material will be provided by contractor except Stay rod (complete set) and stay wire)
Fabrication & erection of End type double pole for 11 KV line on 11 mtr. long ST-Pole with fixing of necessary clamps & other accesories like 02 No. Top channel 100x50 mm (1600mm each), 02 No. Bracing angle 65x65x6x4300 mm, Cable dropper, Disc Insulator with fitting, Danger board, Number plates and Barbed wire etc. (All material will be provided by contractor except ST- pole, Top channel, Bracing angle, cable dropper, Disc Insulator & Disc fitting).
Laying of 11 KV XLPE cable 3x185 sq mm D/C by digging of trench 900 mm deep & 750 mm wide its boxing with bricks & sand, laying of cable & separation of cables by brick wall, filling of sand upto top cover of the trench properly levelling & ramming & covering with stone slab after laying of cable. The ferruling of cable is also included in this work (All material will be provided by contractor except 11 KV cable)
Laying of 11 KV 3x185 sq mm XLPE single cable in GI-Pipe 150 mm dia by digging of cable trench 600 mm wide and 900 mm deep (All materials will be provided by contractor except 11 KV cable)
Hoisting of 11 KV 3x185 Sqmm XLPE cable on D/P through GI- pipe of size 4" dia 3 mtr long including its jumpering complete with holding clamps, PG clamps, Nut & bolts (All material will be provided by contractor)
Making of Heat & shrinkables joints of following sizes and types in 33 KV & 11 KV XLPE cable(Jointing kit will be provided by deptt.)
Outdoor end termination kit for 33 KV 3x300 sqmm XLPE cable
Outdoor end termination kit for 11 KV 3x185 sqmm XLPE cable
Straight through jointing kit for 11 KV 3x185 sqmm
Fabrication & erection of Single pole support (End type) for LT- ABC line on 09/11 mtr ST-Pole with fixing of necessary clamps & other accesories like I/J Hook and suspension etc. (All material will be provided by contractor except ST- pole).
Erection of stay set 16x1800 mm by digging of pit of size 0.4x0.6x1.6 mtr including grouting, binding, nuzzling and fixing of stay insulator with stay wire of size 7/10 SWG (All material will be provided by contractor except Stay rod (complete set) and stay wire).
Erection and commisioning of LT distribution box 3 phase on LT-pole with necessary clamps (Required clamps will be provided by contractor).
Disconnection of existing service cables of consumers and reconnection of service cable from LT-Distribution box after commisioning of LT- Distribution Box.
Earthing of poles with MS- Earthing rod 20x2500 mm, earth wire with nut and bolts as per norms (All material will be provided by contractor except MS-Earthing rods).
High Pressure Testing of 33 KV & 11 KV cable. Testing equipment will be arranged by contractor.
Laying of Double Circuit LT PVC cable 3.5x240 Sqmm by digging of trench 750 mm deep 650 mm wide boxing with brick & sand filling of trench with proper levelling and rumming. (All material will be provided by contractor except LT cables).
Laying of Single Circuit LT PVC cable 3.5x240 Sqmm through GI- pipe 150 mm dia by digging of trench in normal soil. Size of trench 750 mm deep 650 mm wide at road crossing. Levelling & rumming after laying of cable are also included (All material will be provided by contractor except LT cables).
Laying of Single Circuit LT PVC cable 3.5x240 Sqmm through HDPE - pipe 150mm dia by digging of trench in normal soil. Size of trench 750 mm deep 650 mm wide at road crossing. Levelling & rumming after laying of cable are also included (All material will be provided by contractor except LT cables).
Supply, fixing & crimping of required size lugs and its connection with LT lines.
Proper hoisting of LT cable 3.5x240 Sqmm through GI/HDPE- pipe of size 3" dia 2 mtr long including fixing of holding clamps, proper jumpering, Nut & bolts etc (All material will be provided by contractor).
Making of Heat & shrinkables joints suitable for LT-PVC cable of following sizes and types (Jointing kit will be provided by contractor)
Supply & fixing of outdoor jointing kit for LT-PVC cable 3.5x240 sqmm
Supply & fixing of straight through jointing kit for LT-PVC cable 3.5x240 sqmm
Straightening of tilted poles.
Cutting/trimming of tree branches which are touching of LT line, 11 KV line & 33 KV line
Supply and fixing of cable route marker of (33 KV & 11 KV)
Dismantling of 33 KV, 11 KV and LT existing O/H line with shearing of pole (3 No.) & rolling back of ACSR Conductor and ABC.
Dragging, loading & carriage with unloading of dismantled material as scrap from site to Lesa store/JE store.
M/s Khushi Enterprises
AARADHYA AND ADHYATM ASSOCIATES
Sidhi Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid