| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-Finance Being Lowest Bidder | |
| 2 | L2₹17.3 L+₹1.4 L (8.77%)Rejected-Finance MAIN ROAD KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU AND KASHMIR | 181221 | L2 | Rejected-Finance 2nd lowest Bidder | |
| 3 | L3₹19.2 L+₹3.3 L (20.7%)Rejected-Finance CHHURTA JHAJJAR KOTLI JAMMU J K 181222 | 181222 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | L4₹19.7 L+₹3.8 L (24.2%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest Bidder |
Tender Value
₹20.9 L
EMD Value
₹41,700
Closing Date
25 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE (ARMY) DHAR ROAD
Certain Sanctioned works B R and E M at Jindarh under GE (Army) Dhar Road
2023_MES_582173_1
8068/NIT-62/2022-23
Open Tender
Civil Works
Item Rate
240 days
JINDRAH UNDER GE (ARMY) DHAR ROAD
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (ARMY) DHAR ROAD
₹41,700
Yes
27 Mar 2023
21 Feb 2023
27 Mar 2023
22 Feb 2023
25 Mar 2023
6 Mar 2023
Amount
Excavating in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation etc., or for shafts, wells, cesspits, manholes, pier holes laying of GI pipes and Electric cables etc., not exc. 10 sqm on plan and getting out in any type of soil complete all as specified and directed
M & L for cement concrete 1: 4 :8 type D 2 using 40 mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed.
Use and waste form work for flat rough finished surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed.
Use of formwork square, rectangular or polygonal for rough finished surfaces of concrete to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
Use and waste form work to sides and soffits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, over hangs, etc. also splays between floors and beams etc for flat rough finished surfaces of concrete complete all as specified and directed.
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200 mm thick (Horizontal or slopping) for flat rough finished surfaces of concrete complete all as specified and directed.
Use and waste form work to chullah hoods, chajjas, troughs and similar items including edges for flat rough finished surfaces of concrete complete all as specified and directed.
M & L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for Reinforced Cement Concrete (Design Mix) M-25 (20 mm graded aggregates) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, underreamed piles and mass concrete complete all as specified and directed
M & L for Reinforced Cement Concrete (Design Mix) M-25 (20 mm graded aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed
M & L for Reinforced Cement Concrete (Design Mix) M-25 (20 mm graded aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M & L brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L Providing Cement concrete Type C1 1 : 3 : 6 (20mm graded aggregate) as in lintels, upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses copings kerbs etc slightly rounded or chamfered angles and throating complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed
S & F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed
S & F mild steel framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S & F sheet glass, 3 mm thick ordinary quality and glazing with oil putty in square not exc. 0.5 sqm in each pane complete all as specified and directed
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed.
S & F 100 mm butt hinges, medium weight cold rolled mild steel, complete all as specified and directed.
M & L preparing surfaces of wood and wood based materials, steel and iron work, new or old, treating small articles such as stop, covers, gully grating, holdfasts, ends of posts, back of chowkats, etc., area not exc 0.1 sqm and treated with tar or coal tar black paint, each complete all as specified and directed
M & L rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for Reinforced Cement Concrete (Design Mix) M-25 (20 mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed
M & L for Reinforced Cement Concrete (Design Mix) M-25 (20 mm graded aggregates) as in Chajjas complete all as specified and directed
M & L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L rendering 5 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement as in ceilings etc. complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint distemper and priming plastered and other surfaces with chalk whiting, preparatory to distempering complete all as specified and directed.
M & L for laying broken stone or boulders hardcore of guage not exc 63 mm deposited spread and levelled in layers not exc 15 cm thick watered rammed and consolidated to a true surface complete all as specified and directed
M & L for 75 mm thick cement concrete 1:3:6 type C 2 (40 mm graded aggregate ) as in plinth protection, finished even and smooth without using extra cement including forming joint to full depth at every 3.0 mtr interval and every change of direction and filled with mixture of bitumen and sand (1:3) by weight complete all as specified and directed
M & L for 75 mm thick cement concrete 1:4:8 type D 2 (40 mm graded aggregate ) as in sub base, finished even and rough to receive the topping layer complete all as specified and directed
M & L 25 mm thick cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in floors complete all as specified and directed.
M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar (1:6) complete all as specified and directed.
M & L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing incl screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed.
M & L for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dodo and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing incl screed plaster of 10 mm thick on fair faces of brick work in CM 1:3 complete all as specified and directed.
M & L for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) incl priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2 primed surface by forced application complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed
Removing excavated material (soils) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks staging/cage and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.
M & L treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M & L treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface area complete all as specified and directed
M & L treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M & L treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M & L treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed
Surface excavation not exc 30 cm deep getting in any type of soil complete all as specified and directed.
Rolling and consolidating formation surface in cutting with power roller Exc 8 tonne and not exc. 12 tonne surface formed and rolled and consolidated to required gradient and camber, watered and rammed to a true surface complete all as specified and directed
M&L 150 mm for soling (or Sub base) with broken boulders or quaried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M & L for PCC nominal mix M15 (1:2:4) type B0 using 12.5 mm graded coarse stone aggregate as in mass concreting complete all as specified and directed.
M&L for spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed
M & L for forming 12 mm thick expansion joints for concrete slab 100 mm deep, filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' complete all as specified and directed
M & L for cement concrete 1:2:4 type B1 using 20 mm graded aggregate as in surface channels and drains complete all as specified and directed
Supply and fix air cooled split unit air conditioner (Hot and Cold) electric driven single phase of cap of 2 TR , hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary complete alonwith required length of copper pipe , wire and out door unit hanging stand etc all as specified and directed. Note- MS Work, Fastener, Nut Bolt, Welding Work all to be included in above deemed quoted rate
Supply and fix air cooled split unit air conditioner (Hot and Cold) electric driven single phase of cap of 1.5 TR , hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary complete alonwith required length of copper pipe , wire and out door unit hanging stand etc all as specified and directed. Note- MS Work, Fastener, Nut Bolt, Welding Work all to be included in above deemed quoted rate
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooles indoor type & designed for input variation between 130V to 270 V with output voltage stabilized at 230V with accurancy of +2.5 % and of capacity 5.0 KVA.
M&L Sub main wiring complete with two runs of 6 sqmm FRLS single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade, multistranded with copper conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories Concealed to walls / roofs / floors etc., and including provision of PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade 1.5 sqmm for earth continuity conductor and making good the disturbed surfaces also matching the exisiting surfaces all as specified and as directed by Engr-in-Charge. (For measurement purpose (2 run of 6 Sqm + 1 run of 4 Sqmm) and alongwith PVC Conduit of 25 mm size will pe considered as 1 Rm) .
S & F sheet metal AC Box enclosure single pole neutral with two pin earth plug & socket with MCB SP 20 Amp, 240 Volt 'C' series.
Supply & Fixing in repalcement MCB SP, 20 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm 2 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Gloster,Finolex
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
S&F sheet metal enclosure box made out of 3.15 mm thick CRCA sheet with powder coated paint (CPRI approved) single door outdoor type including solid aluminium bus bar of capacity 100 Amp 4 Nos strip with locking arrangements, enclosure box to be fixed on plinth foundation 1:2:4 and 150 mm above ground level including MS angle/ channel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrangement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
M & L for point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
Supply and fix air circulators fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting (Wall Mounted Fans) and making disturbed surface good as before. Note- Fastener, Nut Bolt, Washer, Drilling, including PVC Copper wire required 3 core connecting from ceiling rose to fan and all connected items to be included in above deemed quoted rates.
Excavation in trenches exceeding 1.5 meter wide and not exceeding 3 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, repairs to road cutting, path etc complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, repairs to road cutting, path etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two coat of aluminium paint over a coat of red oxide as specified type 410 SP 55 (11.00 Mtr long) all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
M & L triple pole mechanically operated GOD mounted on insulators and steel frame with operating mechanism worked from ground level 11000 volts grade of current carrying capacity up to 400 Amps complete all as specified and directed .
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following:(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) Earth pit cover square type of size internal size not less than 300x300mm with top openable cover with handle and one side hinges (c) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (d) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. ( e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) GI Wire Beyond 7.5 Mtr Will be Measured and Paid for Separately
Supply and fixing of earth continuity conductor or main earthing lead fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire as specified and directed.
S&F Lightning Arrestor, Gapless metal oxide, distribution class, system voltage-11KV discharge cap 65-KA Line discharge class-1 for all three phases complete with bracket and connection all as specified and directed.
Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core (Earthed)conforming to IS 7098 lead in duct/trenches complete all as specified and directed.
Supply only cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm.
Supply only cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 80 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to GI strip 32 x 6 mm continuity conductor including 40 mm bore pipe light grade for protection of strip by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to earth test point upto 7.5 mtr away from earth electrode all as per plate No 03 of SSR-I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thickness 1:2:4 with 8mm dia CTD 140 mm C/C as reinforcement with suitable handle, watering pipe 20 mm dia light grade with funnel, charcoal salt and testing on completion all as specified and directed by Engr in Charge
Supply and laying in trenches GI pipe light grade with fitting of size 50 mm bore for protection of cable complete all as specified and as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
S&F Sheet metal enclosure box 3.15 mm thick CRCA sheet with power coated paint (CPRI Approved) double door outdoor type including solid aluminium bus bar of capacity 100 amp 4 Nos strip with locking arrangements, enclosure box to be concealed in case of fixing in wall or fixed on plinth foundation including MS angle/ chanel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrengement on pole/wall , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
Supply and laying in trenches GI pipe medium grade with fitting of size 25 mm bore for passing of water complete all as specified and as directed
Supply and laying in trenches GI pipe medium grade with fitting of size 20 mm bore for passing of water complete all as specified and as directed
Supply and Fixing of Gate valve 25 mm bore complete all as specified.
Supply and Fixing of Gate valve 20 mm bore complete all as specified.
Cutting/making hole/cutting into CI/DI/MS pipes of any size pipe carefully and insertion of new GI tee incl clamping with suitable size clamp for taking small branch connection upto 25 mm bore complete all as directed by EIC.
M&L for valve chamber/pit incl necessary earth work in any type of soil, PCC foundation C-2 (1:3:6) type C2 40mm graded stone aggregate as in base concrete ,brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4 , 6 mm thick MS cover with hinges and locking arregement fixed to angle iron frame made out of 30cm x30cm x6 mm MS angles complete with 2 coats of synthetic enemal paint over one coat of red oxide primer on all metal works & three coats of white wash on all plastered surfaces of valve chambers size 300mm x 300mm x 300mm complete all as specified & directed
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 96 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed
Supply & Fixing DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.
S&F Bulk head fitting 10 watt LED incl water proof , weather proof all as specified and directed. Complete all as directed by engr-in-charge
Supply only LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min). complete all as directed by engr-in-charge
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required.complete all as directed by engr-in-charge
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as directed by engr-in-charge along with writing MES number
M/S SANJAY STEEL WORKS
MandeepConstructionCo
M/S PAWAN KUMAR ANAND
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .