Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC M MAHESH | ₹22.5 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹23.2 L+₹66,178.71 (2.94%)Rejected-AOC CHENNAI | CHENNAI | CHENNAI | TAMIL NADU | ₹23.2 L+₹66,178.71 (2.94%) | L2 | Rejected-AOC not Awarded |
Tender Value
₹22.1 L
EMD Value
₹22,100
Closing Date
23 Jan 2026, 3:00 pmClosed
ZONE OFFICE-3
NO.1, THATTANKULAM ROAD, MADHAVARAM, CHENNAI-60
Supplying, Fabricating and fixing in position of Ms Container for Ticket Counter and Store Room, Food Kiosk and First Aid Room for Madhavaram ERI at Kamarajar Salari in DN-27, Unit-7, Zone-3
2026_CoC_641089_1
Z.O.III.C.NO.E1/8986/2025
Limited
Civil Works
Works
120 days
CHENNAI
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹22,100
24 Jun 2026
9 Jan 2026
24 Jan 2026
9 Jan 2026
23 Jan 2026
9 Jan 2026
Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. (including Refilling charges)
Providing and laying in position, standardised concrete Mix M-20 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 1012mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
Laying of cable along road / street through 50mm OD, HDPE pipe (trench size 45cm width x 75 cm depth)
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250 mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Installation of Vertical Bored cast in situ RCC piles of following diameter in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456- 2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap.( Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately ) Grade of Concrete: M25 450 mm dia pile
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply above ground level. For laying PVC pipes of dia 25mm
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply above ground level. For laying PVC pipes of dia 20mm
I.SI.MARKED 31/2X70 SQ.MM CABLE
HDPE pipe of size 90 mmOD x 76mm ID
PVC Pipes WORKING PRESSURE: 4 kg. per sq.cm 110mm dia
Supplying, fabricating and placing in position Ribbed Tor Steel / TMT reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Above plinth / Basement level
Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes Aluminium Dye Cast Letters 9 size
Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes Aluminium Dye Cast Letters 6 size
Painting the wall with Texture Finish Paint including labour charges
Supplying , fabricating and fixing in position of M.S container for Ticket counter and Store room of containers Size : 6M x 2.40M x 2.60M with partition 10x8 ft for ticket counter, 5x 8 ft for Engine service and 5x 8 ft for storage place. Main Entrance Door size : 6.5 ft x 3.5 ft 1 No and MS counter with tray and hinges .LED square light - 2 nos ,5A socket- 2 nos,Tube light -1 no,Bulk head- 1 no ,Wall fan -1 no, MCB- 1no . Internal Panelling : 340sft insulation of thermocol and 8mm MDF sheet 1.3mm vinyl matt for floor Painting: Two coat of Asian enamel paint finish (as per required colour). and two no Rack of size 10feet x 2feet complete complying with standard specification and as directed by the departmental officers
TNEB Charages
Plumbing work
Supplying, Fabricating and fixing in position of M.S container for Caféteria Food Kiosk of Containers Size : 6M x 2.40M x 2.60M Main Entrance Door size : 6.5 ft x 3.5 ft 1 No and MS counter with tray and hinges -1 no , 20x2 ft running table with 18mm plywood &mic aby using MS frame sttucture .LED square light - 3 nos ,5A socket- 3 nos,Tube light -1 no,Bulk head- 1 no ,Wall fan -2 no, MCB- 1no . Internal Panelling : 608sft insulation of thermocol and 8mm calcium silicate baord with one coat wall putty and two coats of primer and Painting ,2 x2 Virtified tiles for floor Painting: Two coat of Asian enamel paint finish (as per required colour). complete complying with standard specification and as directed by the departmental officers
Supplying, Fabricating and fixing in position for First Aid Room and CCTV Room The work involves the creation of an integrated room made from a standard ISO container measuring 6M x 2.4MX2.60M in size. This room will house first aid equipment and CCTV control facilities at the beach location. It requires the installation of a temporary structure made of prefab materials or a container equipped with all necessary equipment for first aid and CCTV control services. The structure must be labeled with their respective names, including "RED CROSS" in front of the first aid area for emergency identification. The scope of work includes design, engineering, fabrication, installation, testing, commissioning, and operationalizing of the integrated tourist facilities as per the design drawings provided.,complete as directed.
Supply fixing name board for (Ticket Counter , First Aid Room, Food Kiosk)
Culvert
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_767795.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
8986.pdf
Tender Documents • 0.48 MB
BOQ_767795.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .