Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹9.6 LAccepted-Finance PIPULBERIA NAKIBASAN TAMLUK PURBA MEDINIPUR 721649 WEST BENGAL | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721649 | 1st | Accepted-Finance 1st lowestbidder | |
| 2 | 2nd₹9.7 L+₹7,638 (0.79%)Rejected-Finance CHALBALPUR PO SITARAMPUR P S KULTI | 2nd | Rejected-Finance 2nd lowest bidder | |
| 3 | 3rd₹9.8 L+₹19,314 (2.01%)Rejected-Finance SARBERIA NARAYANDARI PURBA MEDINIPUR 721655 | NARAYANDARI | PURBA MEDINIPUR | WEST BENGAL | 721655 | 3rd | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹19,644
Closing Date
28 Sept 2024, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OFFICE OF THE SUPERINTENDING ENGINEER,SWEC,PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
E.I. work for construction of Doctor rest room/toilets rest room/ toilet for staff nurses, other female staff and installation of street light with pole at Egra SDH in the district of Purba Medinipur.
2024_WBPWD_752174_1
WBPWD/SE/SWEC/NIQ32/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
PASCHIM MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹19,644
5 Oct 2024
17 Sept 2024
30 Sept 2024
17 Sept 2024
28 Sept 2024
17 Sept 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/RR Kable/polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand- Myrius) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portionconcealed] Average run 8 mtr
On Board 6A 3pin Modular type plug socket & switch [Legrand - Myrius] [E-24/3(a )]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18/9 (B)]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. E-17/ 5(a)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. E-19/ 17
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Distn. Wiring in 1.1 Kv gr. Single core stranded ‘FR’ PVC insulated & unsheathed cu. wire (Havells / RR Kable / Polycab) in 20/32/40 mm size PVC rigid conduit ‘FR (precession) incl. necy. Fitting as reqd. [E-14/1 (a)]
a) 2 x2.5 sqmm + 1x 1.5sqmm for ECC (For Power Plug)
b) 2 x 4 sqmm + 1 x 2.5 sqmm for ECC (for AC)
c) 2 x 126/0.4 (16 sqmm) + 1x80/0.4 (10 sqmm) as ECC (for Shifting UPS sysmtem)
Finishing end of copper wire and PVC/Al cable of the following sizes by crimping method as per GS [F-5/9]
Supply & Delivery of Single LED Tube light fittings (make- Philips, Cat No. TMC-502 P1xT-LED 22W / equivalent model of CG Fittings- IGP161LT8-16 1 x T8 with 01 Nos LED TUBE Philips Cat No- Mas LED Tube 1200mm 18W 865 T8 I – 2100 lm /Crompton- Cat No- LTB-20-865-(2) or equivalent make and model of Havells)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (25mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire andmending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent make of Crompton Greaves and as per direction of EIC as per direction of EIC.
Supply and delivery of 230V 300 mm (12") 920 RPM Heavy Duty Exhaust fan with all necessary accessories [Make: EPC/Usha/ CG or equivalent Make]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. (12")
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & fixing 9W LED lamp to the lamp point. [PHILIPS make]
Supply & delivery of hot dip galvanized (As per IS: 2629/IS 2633/IS 4759 & with its latest amendment) 8 mtrs length decorative octagonal pole made of HT steel( Sheet thickness- 3 mm) conforming to grade S355JO/JR of BSEN 10025 along with a welded base plate of required size stud of termination of 4 core 10/16/25/35 sq. mm al (Ar) cable incl S&F 1 no 6 amp SP MCB (c-series) with 4 way stud for each outgoing circuit to the fittings with proper pad locking arrangement for the pole. [Top dia (A/F)-70 mm Bottom dia (A/F)- 155 mm] Base plate size: 260 mm (L)x 260 mm(W) x 16 mm(Thickness). Foundation Bolt- 4-M24 x 750 mm(L) x 4 nos 'J' type bolts. (Make-Transrail / Valmont/Lysaght/Bajaj) (T.C & G.C must be submitted to EIC before execution) N.B: Specification of poles may be changed as per manufacturer standard, the agency must approve the material from the EIC before execution and should visit the site physically.
S&F 50 mm. dia 1.5 Mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (Make-Transrail / Valmont/Lysaght/Bajaj)
Erection of the following decorative octagonal pole by designing & casting RCC(M-16)foundation of suitable size as specified below considering the safe soil bearing capacity at the site as 10 T/sq m incl excavation of earth providing cutting bending and placing in position reinforcement as per drawing & providing pipe for cable entry & exit as per required & providing and fixing of 4 nos foundation bolt (J type) as specification below & as per drawing on ground surface incl backfilling cleaning extra earth---up to 9 meters. [Foundation size-500mm(L)x500mm(W)x1200mm(H), J Bolt size-M24 x 750mm [L].
S & F of outdoor luminaire ( IP 66 ) with pressure die cast housing with toughened glass and high power LEDs with secondary optics , 10KV SPD, THD < 10%, PF> 0.95, BIS approved, minimum LPW: 110 lumen/ Watt, 230Volt, 50Hz. [Make: Philips:- BRP033 LED100 CW SLR GR PSU SPD/ Crompton/Wipro].
Supplying of 1.1 KV Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size. [ Make : Gloster / Polycab / Havells / RR Kabel ]
4 core 10 sqmm
Laying of one No. cable up to 35 sq.mm in the underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 10 sqmm
Supplying & fixing 50 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Inter connection of compound light fittings by 3 x 1.5 Sq. mm. PVC insulated copper wire ( Finolex/Polycab/Havells) through 19 mm polythene pipe from loop box inside the pole to light fittings through pole & bracket with Pricision MMS PVC pipes as per direction of EIC
Earthing with 50 mm dia GI pipe (ISI-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts below the ground level. [PWD /GS, Item no. 2( a), Page no. G-1]
Connecting the equipments body to earth busbar incl. S & F 20 mm x 3 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [PWD/GS, Item No. 5(c), Page No. G3]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [PWD/GS, Item No. 1 (a), Page No. G-1]
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [PWD/GS, Item No. 5(d), Page No. G-3]
Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below [H-2/6(b)] a) Size 50 mm and upto 75 mm [PWD/GS, Item No. 6(b), Page No. H-2]
Supply and delivery of Non inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required : 18000 BTU / Hr. or Higher (b) Minimum Star rating- 2 Star or higher (c) Rated voltage—230V +/-5%, Frequency-50Hz. (d) Compressor type- Rotary. (e) Mini. Room Discharge air flow rate - 620 CFM or higher f) Condencer tupe -Copper condencer coil g) Minimum Tonnage required : 1.5T or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. ( Make:- Mitshubishi Electric Model- MS/MU- GK18VA /O-General Model - ASGA18BMWA-B / Mitshubhisi Heavy Industries)
Supply, Installation & commissioning of (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (Make-Ryoku/Rajco/Nippon) with 9 mm nitrile rubber tube Insulation on the following sizes of the suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex) with max saddling with max 1-meter distance both for suction & discharge pipe complete with fittings, elbows, bends, and supporting arrangements on walls.
S & Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make--Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
Installation of the Split type 2.0 Ton A.C machine incl cutting of wall etc incl S & F suitable sizes Copper pipe of same make for Suction & Liquied line with insulation incl. S & F drain pipe of reqd. length to comp. the instn and mending good the damages as per direction of EIC.
Supply & charging suitable R32/R410A gas for the 04 nos 2.0 Ton capacity Split type AC Machine as per direction of EIC by contractors own tools and skilled technicians.
GITANJALI ENTERPRISE (BID ID -5637818)
MAA NACHINDA ELECTRIC (BID ID -5603507)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .