| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.9 LQualified Make: feelfree
Model: Staar Tek A 1 BLOCK B DURGA MARKET SECTOR 53 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201307 UDYAM UP 28 0002174 09AAGFE6392R1ZI R M | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201307 | Make: feelfree
Model: Staar Tek | ₹1.9 L | L1 | Qualified |
| 2 | L3₹2.5 LQualified Make: SMART BUDDY
Model: AT-SNI-SCU-A025-TC 4 SAYALI DARSHAN WING A RADHA NAGAR BEHIND SWAMI SAMARTH KENDRA MAKHMALABAD ROAD PANCHVATI NASHIK MAHARASHTRA 422003 | NASHIK | MAHARASHTRA | 422003 | Make: SMART BUDDY
Model: AT-SNI-SCU-A025-TC | ₹2.5 L | L3 | Qualified |
| 3 | L4₹2.8 LQualified Make: SMART BUDDY
Model: AT-SNI-SCU-A025-TC | Make: SMART BUDDY
Model: AT-SNI-SCU-A025-TC | ₹2.8 L | L4 | Qualified |
| 4 | L6₹2.9 LQualified Make: EVA
Model: EVA | Make: EVA
Model: EVA | ₹2.9 L | L6 | Qualified |
| 5 | L7₹2.9 LQualified Make: Snowy
Model: SANITARY MACHINE MAHESH RAM 1ST FLOOR OPP GOVERNMENT SCHOOL KISHOREGANJ GARIKHANA CHOWK P S SUKHDEO NAGAR RANCHI RANCHI JHARKHAND 834001 UDYAM JH 20 0003307 20AANCA6293K1ZF R B M MII STATUS AS VERIFIED | RANCHI | JHARKHAND | 834001 | Make: Snowy
Model: SANITARY MACHINE | ₹2.9 L | L7 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Aug 2018, 3:00 pmClosed
Sanitary Napkins Incinetator Machine with Smoke Control Unit Sanitary Napkins Incinetator Machine With Smoke Control Unit ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type - - Purpose Burn used Sanitary Napkins to sterile ash and stop automatically - Color - - Operation Mode Electronically operated
fully Automatic - Loading Type - - Stand provided false true
false Number of chambers Two - Trap Door available Yes - All MS parts Powder coated Yes - Spare parts should be available for Minimum 5 years from date of supply Yes - All electrical parts are ISI Marked Yes - DIMENSIONS OF MAIN UNIT Thickness of thermal Insulation material (mm) 25 25
40 1/8 Thickness of MS/SS sheet of housing cabinet (external) (mm) 1.2 - Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) 3 3
5 Higher is better Machine Width(mm) - - Machine Depth (mm) - - Machine Hight(mm) - - Machine Weight(kg) 5-15 5-15
16-30
31-50
51-250 Door width(mm) - - Door height(mm) - - Thickness of door (mm) 20 20
25
40
50
60 Internal/burning chamber shape - - Flexible emission Outlet pipe dia (mm) - 25
63
76 Detachable ash tray length (mm) - - Detachable ash tray width (mm) - - Detachable ash tray height (mm) - - Stand Height (mm) - - Stand Width (mm) - - Stand Depth (mm) - - MATERIAL OF MACHINE UNIT Material of Housing cabinet (External) Stainless Steel sheet of SS-304 grade Mild Steel(CRCA) sheet
Stainless Steel sheet of SS-304 grade Material of Burning chamber (Internal) Mild Steel(CRCA) sheet Mild Steel(CRCA) sheet
Stainless Steel sheet of SS-304 grade Finish of MS parts of cabinet Epoxy anti rust proof painting for superior finish - Material of Thermal Insulation High Density Ceramic Fiber sheet High Density Ceramic Fiber sheet
High Density Ceramic Board CONSTRUCTIONAL FEATURES Thermal insulation of burning chamber housed in outer chamber Yes - 2/8 Burning Chamber tray provided Yes - Emission Outlet pipe location - - Means of connecting the unit outlet with flue gas emission pipe - - Type of door lock provided Latch lock - CONTROL & FUNCTIONAL FEATURES Temperature indicator provided Yes - Timer provided Yes - Auto cut-off temperature display Yes - Digital display to see actual and set temperature false - Minimum Burning temperature (degree C) 800 - Burning Capacity per day (Number of Napkins) 15-50 15-50
51-100
100-200
200-500
500-700
700-1000
1000-1250 Burning Capacity at a time (Number of Napkins) 1-15 1-15
16-25
26-50 Residue Ash per Napkin (gms) 1 - Burning time of full capacity Napkins/pads (minutes) 10 As per GeM Catalogue. Skin temperature of the unit under operation (deg C) 0-15 - Installation
training
demonstration and plumbing included Yes - ELECTRICAL AND SAFETY FEATURES Automatic digital controller for time Yes - Automatic digital controller for temperature Yes - Equipment ON/OFF indicator provided Yes - Power supply - - Electrical Power - - 3/8 Consumption(Watt) Minimum length of power chord to be supplied along with machine (mtr) 2 - Type of Heater Tubular heater - Power saver (auto power cut-off) Yes - Safety MCB provided (16A to 30A) Yes - Protection against electric shock when checked as per IS:302-1/2008 Yes - Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) 2 - Maximum Electrical Insulation and Leakage current as per IS:302-1/2008
(mA) 0.21 - Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) 0.1 - HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 No breakdown shall occur during the test - SMOKE CONTROL UNIT (SCU) Type of SCU (Smoke Control Unit) - - Material of housing of Smoke Control Unit (SCU) Mild Steel(CRCA) cabinet Mild Steel(CRCA) cabinet
Stainless Steel of SS-304 grade Finish of MS parts of SCU cabinet - - Overall height of SCU (mm) - - Overall width of SCU (mm) - - Overall depth of SCU (mm) - - Number of chambers for filteration of smoke emission Two - Both carbon Control and Foul odour Control Chambers for filteration of smoke emission Yes - 4/8 Number of filters in Carbon control chamber One One
Two
Three Type of filters in Carbon control chamber Activated Carbon filter Teflon filter
Activated Carbon filter
Steel mesh filterr
Teflon filter & Activated Carbon filter
Teflon filter
Activated Carbon filter & Steel mesh filter
Ceramic blanket as a filter Number of filters in Odour control chamber One One
Three Type of filters in Odour control chamber Activated Carbon filter - Blower type "Centrifugal
direct driven" - Blower RPM 1800 1800
2700 Power supply of SPU 230v +/-10%
50Hz
Single phase
AC supply - Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) 3 - Cost of additional flexible emission outlet pipe
if required on actuals to be paid by the user Yes - EMISSION STANDARD FOR SMOKE Conformity to CPCB
Min of Environment & Forests standard HAZWAMS/30/2005-06 Yes - Particulates (Half hourly average) (mg/Nm3) (Max) 50 - HCl (Half hourly average) (mg/Nm3) (Max) 50 - SO2 (Half hourly average) (mg/Nm3) (max) 200 - CO (Half hourly average) (mg/Nm3) (Max) 100 - 5/8 CO (Daily average) (mg/Nm3) (Max) 50 - Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) 20 - HF (Half hourly average) (mg/Nm3) (Max) 4 - "Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" 400 - Total dioxins and furans ( 6 to 8 hours sampling basis
Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) 0.1 - Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Sb+As+Pb+Cr+Co+Cu +Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.5 - Loss on ignition (max) (% dry weight of the material) 5 - PACKING Packing - - MARKING AND INSTRUCTIONS The appliance is marked as per IS:302-1/2008 Yes - CERTIFICATION Submission of Test Report from Central Government NABL/ILAC accredited Lab specifically Yes - 6/8 containing Electrical & Electronic parameters
Thermal insulation material of burning chamber etc in addition to the declared specification parameters at the time of supply Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollotution Control Board (CPCB) norms from NABL accredited lab at the time of supply Yes - Certification Available Other - Certificate for Manufacturing premises available ISO - Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier Yes - Submission of all the certifications to the buyer along with supplies Yes - PERFORMANCE REQUIREMENTS Warranty (Yrs) 1 1
2
3
4
5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sameer Rajkamal Ganvir 441302
Municipal Council Katol
Dist- Nagpur 13 15
400173
GEM/2018/B/56636
Sanitary Napkins Incinetator Machine with Smoke Control Unit
15 days
Maharashtra; Nagpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Sanitary Napkins Incinetator Machine with Smoke Control Unit Sanitary Napkins Incinetator Machine With Smoke Control Unit ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type - - Purpose Burn used Sanitary Napkins to sterile ash and stop automatically - Color - - Operation Mode Electronically operated | - | - | - |
| fully Automatic - Loading Type - - Stand provided false true | - | - | - |
| false Number of chambers Two - Trap Door available Yes - All MS parts Powder coated Yes - Spare parts should be available for Minimum 5 years from date of supply Yes - All electrical parts are ISI Marked Yes - DIMENSIONS OF MAIN UNIT Thickness of thermal Insulation material (mm) 25 25 | - | - | - |
| 40 1/8 Thickness of MS/SS sheet of housing cabinet (external) (mm) 1.2 - Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) 3 3 | - | - | - |
| 5 Higher is better Machine Width(mm) - - Machine Depth (mm) - - Machine Hight(mm) - - Machine Weight(kg) 5-15 5-15 | - | - | - |
| 16-30 | - | - | - |
| 31-50 | - | - | - |
| 51-250 Door width(mm) - - Door height(mm) - - Thickness of door (mm) 20 20 | - | - | - |
| 25 | - | - | - |
| 40 | - | - | - |
| 50 | - | - | - |
| 60 Internal/burning chamber shape - - Flexible emission Outlet pipe dia (mm) - 25 | - | - | - |
| 63 | - | - | - |
| 76 Detachable ash tray length (mm) - - Detachable ash tray width (mm) - - Detachable ash tray height (mm) - - Stand Height (mm) - - Stand Width (mm) - - Stand Depth (mm) - - MATERIAL OF MACHINE UNIT Material of Housing cabinet (External) Stainless Steel sheet of SS-304 grade Mild Steel(CRCA) sheet | - | - | - |
| Stainless Steel sheet of SS-304 grade Material of Burning chamber (Internal) Mild Steel(CRCA) sheet Mild Steel(CRCA) sheet | - | - | - |
| Stainless Steel sheet of SS-304 grade Finish of MS parts of cabinet Epoxy anti rust proof painting for superior finish - Material of Thermal Insulation High Density Ceramic Fiber sheet High Density Ceramic Fiber sheet | - | - | - |
| High Density Ceramic Board CONSTRUCTIONAL FEATURES Thermal insulation of burning chamber housed in outer chamber Yes - 2/8 Burning Chamber tray provided Yes - Emission Outlet pipe location - - Means of connecting the unit outlet with flue gas emission pipe - - Type of door lock provided Latch lock - CONTROL & FUNCTIONAL FEATURES Temperature indicator provided Yes - Timer provided Yes - Auto cut-off temperature display Yes - Digital display to see actual and set temperature false - Minimum Burning temperature (degree C) 800 - Burning Capacity per day (Number of Napkins) 15-50 15-50 | - | - | - |
| 51-100 | - | - | - |
| 100-200 | - | - | - |
| 200-500 | - | - | - |
| 500-700 | - | - | - |
| 700-1000 | - | - | - |
| 1000-1250 Burning Capacity at a time (Number of Napkins) 1-15 1-15 | - | - | - |
| 16-25 | - | - | - |
| 26-50 Residue Ash per Napkin (gms) 1 - Burning time of full capacity Napkins/pads (minutes) 10 As per GeM Catalogue. Skin temperature of the unit under operation (deg C) 0-15 - Installation | - | - | - |
| training | - | - | - |
| demonstration and plumbing included Yes - ELECTRICAL AND SAFETY FEATURES Automatic digital controller for time Yes - Automatic digital controller for temperature Yes - Equipment ON/OFF indicator provided Yes - Power supply - - Electrical Power - - 3/8 Consumption(Watt) Minimum length of power chord to be supplied along with machine (mtr) 2 - Type of Heater Tubular heater - Power saver (auto power cut-off) Yes - Safety MCB provided (16A to 30A) Yes - Protection against electric shock when checked as per IS:302-1/2008 Yes - Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) 2 - Maximum Electrical Insulation and Leakage current as per IS:302-1/2008 | - | - | - |
| (mA) 0.21 - Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) 0.1 - HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 No breakdown shall occur during the test - SMOKE CONTROL UNIT (SCU) Type of SCU (Smoke Control Unit) - - Material of housing of Smoke Control Unit (SCU) Mild Steel(CRCA) cabinet Mild Steel(CRCA) cabinet | - | - | - |
| Stainless Steel of SS-304 grade Finish of MS parts of SCU cabinet - - Overall height of SCU (mm) - - Overall width of SCU (mm) - - Overall depth of SCU (mm) - - Number of chambers for filteration of smoke emission Two - Both carbon Control and Foul odour Control Chambers for filteration of smoke emission Yes - 4/8 Number of filters in Carbon control chamber One One | - | - | - |
| Two | - | - | - |
| Three Type of filters in Carbon control chamber Activated Carbon filter Teflon filter | - | - | - |
| Activated Carbon filter | - | - | - |
| Steel mesh filterr | - | - | - |
| Teflon filter & Activated Carbon filter | - | - | - |
| Teflon filter | - | - | - |
| Activated Carbon filter & Steel mesh filter | - | - | - |
| Ceramic blanket as a filter Number of filters in Odour control chamber One One | - | - | - |
| Three Type of filters in Odour control chamber Activated Carbon filter - Blower type "Centrifugal | - | - | - |
| direct driven" - Blower RPM 1800 1800 | - | - | - |
| 2700 Power supply of SPU 230v +/-10% | - | - | - |
| 50Hz | - | - | - |
| Single phase | - | - | - |
| AC supply - Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) 3 - Cost of additional flexible emission outlet pipe | - | - | - |
| if required on actuals to be paid by the user Yes - EMISSION STANDARD FOR SMOKE Conformity to CPCB | - | - | - |
| Min of Environment & Forests standard HAZWAMS/30/2005-06 Yes - Particulates (Half hourly average) (mg/Nm3) (Max) 50 - HCl (Half hourly average) (mg/Nm3) (Max) 50 - SO2 (Half hourly average) (mg/Nm3) (max) 200 - CO (Half hourly average) (mg/Nm3) (Max) 100 - 5/8 CO (Daily average) (mg/Nm3) (Max) 50 - Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) 20 - HF (Half hourly average) (mg/Nm3) (Max) 4 - "Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" 400 - Total dioxins and furans ( 6 to 8 hours sampling basis | - | - | - |
| Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) 0.1 - Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Sb+As+Pb+Cr+Co+Cu +Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.5 - Loss on ignition (max) (% dry weight of the material) 5 - PACKING Packing - - MARKING AND INSTRUCTIONS The appliance is marked as per IS:302-1/2008 Yes - CERTIFICATION Submission of Test Report from Central Government NABL/ILAC accredited Lab specifically Yes - 6/8 containing Electrical & Electronic parameters | - | - | - |
| Thermal insulation material of burning chamber etc in addition to the declared specification parameters at the time of supply Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollotution Control Board (CPCB) norms from NABL accredited lab at the time of supply Yes - Certification Available Other - Certificate for Manufacturing premises available ISO - Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier Yes - Submission of all the certifications to the buyer along with supplies Yes - PERFORMANCE REQUIREMENTS Warranty (Yrs) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sameer Rajkamal Ganvir 441302 | - | - | - |
| Municipal Council Katol | - | - | - |
| Dist- Nagpur 13 15 | - | - | - |
Exempted
21 Aug 2018
10 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_400173.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid