Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.8 L+₹5.1 L (17.6%)Rejected-Finance | L2 | Rejected-Finance Being a higher bidder | |
| 3 | L3₹36.8 L+₹8.1 L (28.2%)Rejected-Finance | L3 | Rejected-Finance Being a higher bidder | |
| 4 | L4₹38.7 L+₹10.0 L (34.7%)Rejected-Finance | L4 | Rejected-Finance Being a higher bidder | |
| 5 | L5₹38.9 L+₹10.2 L (35.4%)Rejected-Finance | L5 | Rejected-Finance Being a higher bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
6 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF ADDN/ALTN TO BLDG NO EW-7, 115 AND CERTAIN SANCTIONED WORKS IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2021_MES_487290_1
GE/EM/LKO/HOSP/T-51 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category a (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹78,000
Yes
28 Dec 2021
9 Nov 2021
8 Dec 2021
9 Nov 2021
6 Dec 2021
23 Nov 2021
60 days
Amount
Excavation over areas not exceeding 1.5 M deep and getting out in any type of soil complete all as specified and directed.
Excavation over areas exceeding 1.5 M deep and not exceeding 3 M deep and getting out in any type of soil complete all as specified and directed.
Excavation over areas exceeding 3 M deep and not exceeding 4.5 M deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., n.exc 10 Sqm on plan and getting out in Soft/ Loose soil complete all as specified and directed.
M&L for hard core of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and roolled rammed to a true surface of broken bricks complete all as specified and directed.
M&L for hard core of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and roolled rammed to a true surface of broken stone or boulders complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
Hand packing (any thickness) with broken bricks at back of walls in soak well, over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for Plain/ Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in roof kerb, mud stops, channel/ benching of manhole laid to shape and slope surface finished even and smooth using extra cement including necessary formwork rounded or chamfered on edges complete all as specified and directed.
M&L for Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for Reinforced Cement Concrete Type B0 1:2:4 (using 12.50 mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in beams, lintel band, plinth band, cantilevers, bressumers, lintel over 1.5 Mtr clear span complete all as specified and directed.
Supply only Integral water proofing compound ISI mark, complete all as specified and directed.
Supply only liquid water proofing compound ISI mark, complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, in one brick thick honey comb walling built in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, in half brick thick honey comb walling built in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work with FLYASH `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all specified and directed.
M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick (horizontal or sloping) work as rough finished curved surfaces of concrete complete all as specified and directed.
M&L for Fair finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc for fair finished surfaces of concrete complete all as specified and directed.
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) not exceeding 1.5 Sq. M each including iron mongries, hold fast etc and including making good disturbed portions of walls in CM 1:4 complete all as specified and directed.
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) exceeding 1.5 Sq. M but n.exc 4.0 Sqm each including iron mongries, hold fast etc and including making good disturbed portions of walls in Cm 1:4 complete all as specified and directed.
S & F for powder coated aluminium extruded sections (conforming to IS) (minimum thickness of powder coating 50 micron) three track sliding window shutter with frames comprising series-C (20mm) , duly fitted with neoprene beading, glazing clipss, locking devices, tinted glass 4.8mm thickness (in 2 shutters) and with SS wire cloth of 0.46mm nominal dia of wire and average width of aperature 1.4mm (in one shutter) complete all as specified and directed.
S&F Aluminium Anodised powder coated grill weight 3.13 Kg per Sqm (min) with grill frame weight 0.297 per mtr (min) fixed with frame in windows/ventilator , complete all as specified and directed.
S&F in repairs powder coated aluminium sections (conforming to IS) door frame with double leaf shutters complete duly fitted with neoprene rubber beading, heat absorbin glass panes 4.8 mm nominal thickness, Aluminum anodised rubber shoe floor door stopper-02 Nos (of size 100mm), Handle 2 Nos (of size 100 mm) fabricated in each shutter, aluminium anodised tower bolt -01 Nos (of size 200 mm) in each shutter and necessary locking arrangement with mortice lock, floor spring with duplicate key complete all as specified and directed.
Repairing of existing aluminium door double leaf including oiling and greasing of floor springs,replecing of rubber beading if required,replacement of hinges,handle,towerbolt of existing size any type present at site on required basis,also including replacement of any membre of aluminium section i.e frame & shutters membre and 5-12 mm glass and making the door and shutter serviceable complete all as specified and directed.
Repairing of existing aluminium door single leaf including oiling and greasing of floor springs,replecing of rubber beading if required,replacement of hinges,handle,towerbolt of existing size any type present at site on required basis,also including replacement of any membre of aluminium section i.e frame & shutters membre and 5-12 mm glass and making the door and shutter serviceable , complete all as specified and directed.
S & F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified or as directed.
Supply and fix Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
Supply and fix in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
S & F 11 to 15 mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. (Note-Length of ordinary bolts shall be measured from the underside of the head to the end of shank)
S & F Rolled Mild Steel sections confirming to Fe 410 - S (Gde-E-250) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates including rivets or bolt and necessary welding etc complete all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel ventilator with centre hung shutters including two pairs of brass cup pivots, catch spring and pulley wheel complete all as specified and directed.
Fabrication, erection and fixing of rolled section gde Fe 410 -W (Gde- E- 250) quality as in main and cross beams, hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates incl. rivets or bolt complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws made to any shape or semi-circular any colour complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet on ridge 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws made to any shape or semi-circular any colour complete all as specified and directed.
M & L 6 mm thick Asbestos Cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with J or L hook complete all as specified and directed.
M&L Suspended ceiling, comprising 12.5 mm thick reinforced gypsum plaster boards Conforming to IS-2095 , GI perimeter channels, intermdiate channels, etc. including finishing the exposed surfaces with Oil bound distemper two coats complete all as specified and directed. (Note : size of section as per specification here-in-after or as per manufacturer's instructions)
M & L for machine cut kota stone slab flooring 20-25 mm thick over and including 20 mm cement screed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed.
M&L for 75 mm thick cement concrete, type C 2, 1:3:6 (using 40 mm graded stone aggregate) as in sub base, paving, plinth protection finished even and fair complete all as specified and directed.
M&L for 100 mm thick cement concrete, type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring finished rough to receive finishes complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.50 mm graded stone aggregate) in floorings including finishing the surface even and fair to receive floor finishes complete all as specified and directed.
M&L for coloured printed glazed ceramic tiles 7 to 8 mm thick on walls dado/skirting (square/ rectangular) of 300x200 mm jointed and pointed with coloured cement over and including 10 mm thick rendering in cement mortar 1:3 for complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:3 complete all as specified and directed.
M&L for Non - skid joint free coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm laid on floor surface jointed and pointed with coloured cement over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm laid on vertical surface jointed and pointed with coloured cement over and including 10 mm thick rendering in cement mortar 1:3 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, kota stone/granite slab including screed bed and removing rubbish off the premises complete all as specified and directed.
M&L for Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified and directed.
S & F Polythene film, black 50 micron thick laid in floors/ walls complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement with WPC @3% by weight of cement complete all as specified and directed. (Note: WPC shall be measured and paid seperately.)
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for preperation of new wall surfaces by thin layer of Birla Wall care putty and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preperation of old wall surfaces by applying a thin layer of Birla Wall care putty and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and apply a thin layer of white wall care putty to obtain smooth regular/even finish using sand paper and than applying two coats of exterior emulsion paint (1st quality) complete all as specified and directed. Note:- The tint/ shade of the paint shall be as approved by the GE.
M&L for complete removal of existing treatment on old wall surfaces and preparation of old surface of walls and apply a thin layer of white wall care putty to obtain smooth regular/even finish using sand paper and than applying two coats of exterior emulsion paint (1st quality) over a coat of primer complete all as specified and directed. Note:- The tint/ shade of the paint shall be as approved by the GE.
S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
M&L for preparation of old wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed.
M & L 150 mm bore RCC Class NP-3 pipes laid and jointd complete with collars in trenches and jointed in CM 1:1 complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required complete all as specfied and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of existing roofing asbestos cement corrugated or semicorrugated etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and directed.
Taking down carefully aluminium/ copper point wiring from existing place (light/fan, socket or power points) complete with all fixtures and fittings such as switches, sockets, ceiling rose, pendant holder, regulators, light fitting etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper or white colour wash and removing materials to store for keeping in safe custody or for credit all as required and complete all as specified and directed
M & L Point wiring (concealed type) with 1.5 Sqmm(Nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor (FRLS) single core cable drawn through and including PVC non metallic conduit of 20 mm dia medium grade ISI mark with complete accessories, including mild steel sunken 1.6 mm thick terminal boxes with 3 mm thick bakelite sheet top cover ISI marked including PVC insulated and unsheathed single core multistranded copper conductor cable (FRLS) of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One fan point controlled by one way switch and fan regulator complete all as specified and directed
M & L Point wiring (concealed type) with 2.5 Sqmm(Nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor (FRLS) single core cable drawn through and including PVC non metallic conduit of 20 mm dia medium grade ISI mark with complete accessories, including mild steel sunken 1.6 mm thick terminal boxes with 3 mm thick bakelite sheet top cover ISI marked including PVC insulated and unsheathed single core multistranded copper conductor cable (FRLS) of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One 15 Amps socket point controlled by one way switch and fan regulator complete all as specified and directed
All as per Sl No 80 above but one socket outlet point 5 Amp on same board other switches complete all as specified and directed
All as per Sl No 80 above but one socket outlet point 5 Amps on independent board complete all as specified and directed
M&L for Sub main wiring (Concealed type) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, drawn through and including PVC non metallic conduit medium grade ISI mark of 20mm dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor (FRLS) cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M&L for Sub main wiring (Concealed type) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 6.0 sqmm LT, 1100V grade, drawn through and including PVC non metallic conduit medium grade ISI mark of 20mm dia with accessories and fittings and one run of 6 sq mm single core multi stranded copper conductor (FRLS) cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M&L for Sub main wiring (Concealed type) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 10.0 sqmm LT, 1100V grade, drawn through and including PVC non metallic conduit medium grade ISI mark of 20mm dia with accessories and fittings and one run of 10 sq mm single core multi stranded copper conductor (FRLS) cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 16/20 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 6 pin 20 Amps flush type controlled by one switch complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 5 pin 5 Amps flush type controlled by one switch complete all as specified and directed.
S&F Ceiling rose three terminal /PVC/polycarbonate, insulated body complete all as specified and directed.
S&F steped type (05 step) electronic fan regulator delux type 240V ISI mark on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F batten/ angular type, Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings suitable for pendant fittings complete all as specified and directed.
S&F double door MCB Epoxy powder coated distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways IP43 grouted flush to walls complete all as specified and directed. (Note : Isolaters/ MCBs to be measured separately under respective item.)
Supply and fixing Distribution board TPN with and including DPX MCCB 35ka 160 Amps MCCB FP-01 No and MCB SP 32 Amps 230V-24 Nos and blanking plate with MCCB as incomer and MCBs as outgoing protection class IP 54, 8 way (DPX 160 + 24) with metal door double door complete all as specified and directed.
S&F Miniature circuit breakers (MCBs) ISI marked 240 Volt, 50 Hz, single pole 6-32 Amps, breaking capacity 10 KA complete all as specified and directed.
S&F Miniature circuit breakers (MCBs) ISI marked 240 Volt, 50 Hz, single pole 40-63 Amps, breaking capacity 10 KA complete all as specified and directed.
S&F single pole and neutral enclouser with and including a two pin earth plug and socket complete with and including one single pole MCB of rating 32 Amps 240 volt grade complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion.
S&F recess mounting LED light fitting of size 2'x2' 42 Watt LED made of CRCA powder coated finish wih fully covered by PMMA Acrylic Lumio Diffuser, LED used shall be SMD type and fixture including cutting and making false ceiling of any pattern/material, proper fixing of light in false ceiling, electrical connection upto 15 feet height of various ward and Deptt complete all as specified and directed.
S&F recess mounting LED light fitting of round shape 10 watt LED made of CRCA powder coated finish wih fully covered by PMMA Acrylic Lumio Diffuser, LED used shall be SMD type and fixture including cutting and making false ceiling of any pattern/material, proper fixing of light in false ceiling, electrical connection upto 15 feet height of various ward and Deptt complete all as specified and directed.
S&F LED batten with LED tubelight rod 18 Watt 4 feet retro type complete all as specified and directed.
Supply, installing, commissioing and testing , inverter type, split type Air Conditionerof capacity 1.5 TR (Dual mode Hot & Cool, inverter type) 3 star rated with inbuilt air ioniser and plasma filter, rotary compressor, auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins, auto fan speed, electric drien, suitable for working on 230 volts, single phase, 50 HZ supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation complete all as specified and directed. Make :- Voltas/Hitachi/ Daikin/bluestar. The rate is included for following item- (a) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe (b) S&F cutting, bent to shape copper pipe of appropriate size from outdoor unit to indoor unit by cutting holes to wall including brazing the copper pipe fixing union including making good disturbed surfaces as existing. (c) S&F PVC pipe 20 mm dia transparent flexible heavy duty for water drainage pipe of upto 06 RM at site. (d) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm/reqd size for mechanical protection of copper pipe complete. (e) Charging of correct qty of refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load to obtain 18 degree celsius temperature at specified amps. (f) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. (g) outdoor AC portion to be fixed on wall mounted stand as suitable for fixing of AC. (H) Plug top to be provided by contractor to with AC wire.
Supply, installation, commissioning and testing Voltage stabilizer automatic boost/buck transformer for low and hih voltage with electroic transistorised relay/time relay for two min, SP, 50 Hz with volt meter indicator and input voltage 140 to 280 and cut up voltage 215 to 240 V cap 4 Kva complete all as specified and directed. Make-V-Guard Model No-VND 400 PLUS
S&F ceiling fan 1200 mm sweep, five star rating with remote control, AC 230 Volts single phase including making connection with two core PVC insulated 1100 Volts grade multi stranded copper wire of size 1.00 sqmm including testing complete all as specified and directed.
S&F Metallic body exhaust fan 300 mm sweep AC 230 Volts, copper bounded single phase with louvers including making connection with two core PVC insulated 1100 Volts grade multi stranded copper wire of size 1.00 sqmm including testing complete all as specified and directed.
S&F Metallic body exhaust fan 380 mm sweep AC 230 Volts , copper bounded, single phase with louvers including making connection with two core PVC insulated 1100 Volts grade multi stranded copper wire of size 1.00 sqmm including testing complete all as specified and directed.
S&F Metallic body exhaust fan 450 mm sweep, heavy duty, AC 230 Volts , copper bounded, single phase with louvers including making connection with two core PVC insulated 1100 Volts grade multi stranded copper wire of size 1.00 sqmm including testing complete all as specified and directed.
S&F Exhaust fan PVC body fresh air 250 mm sweep AC 230 Volts single phase with louvers including making connection with two core PVC insulated 1100 Volts grade multi stranded copper wire of size 1.00 sqmm including testing complete all as specified and directed.
S&F DLP 105x50mm PVC wih cover plate, seperator, angle, end cap, joints, partiion with all accessories as required complete all as specified and directed.
S&F flexible copper cable 2 core, 1 sqmm size suitable for connection of light fittings/FTL fittings of any type complete ll as specified and directed.
M&L for shifting of split type AC upto 05 mtr distance from existing location including copper pipe, cover, necessary gas charging, fixing on wall for all other connected civi works & othermisc work required for installation of split AC for proper functioning complete all as specified and directed. (h) Additional length of copper tubes (upto 15 RM) for compressor inlet/oulet with insulating material).
M R CONSTRUCTION
PUMA POWER
M/s Sultan Khan
M/S SWATI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .