Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance | L1 | Accepted-Finance OK |
Tender Value
₹1.9 L
EMD Value
₹3,852
Closing Date
19 Apr 2023, 3:00 pmClosed
Executive Engineer (Elect)
T.E. Building KBN, Room No -25, Kidwai Bhawan MTNL, New Delhi-110001
SITC of window air-conditioning and split air-conditioning units at TE Bldg. JLN Marg, MTNL Delhi
2023_MTNL_749036_1
EE(E)KBN/2023-24/13-04-23/04
Open Tender
Electrical Works
Item Rate
7 days
Kidwai Bhawan
Please refer Tender documents.
9 documents required · 9 mandatory
₹590
MTNL Delhi
₹3,852
20 Apr 2023
13 Apr 2023
20 Apr 2023
13 Apr 2023
19 Apr 2023
13 Apr 2023
Amount
SITC OF WINDOW A.C. Supplying of window type air-conditioning unit having copper coils (Minimum 3 star rated as per BEE Notification dated 19th April 2022)of following rating suitable as per technical data sheet and detailed specifications attached including cordless remote, suitable for operation on 230V+/- 10%, 50Hz single phase a.c. supply, having digital display panel;installation/fixing in already existing window with necessary alignment, suitable electric cable (up-to 5mtr length)of 3x4sq.mm.copper-conductor PVC insulated PVC sheathed power cable of 1100V grade,drain pipe, testing for satisfactory working without any abnormal noise/vibrations. Warranty shall be 1 year for the complete machine and 5 year for compressor. Note: Scope of work also includes: A. Carpentry work for making the window frame and fixing of wooden frame wherever required as per actual site requirements. B. 16A-25A Plug Tops 1.5TR for cooling
Supplying of split type inverter air-conditioning unit having copper coils (Minimum 3 star rated as per BEE Notification dated 19th April 2022)of following rating suitable as per technical data sheet and detailed specifications attached including cordless remote, suitable for operation on 230V+/- 10%, 50Hz single phase a.c. supply, having digital display panel;installation/fixing of indoor unit and outdoor unit, suitable size 415V/1100V grade copper-conductor PVC insulated PVC sheathed power cable of required length with 16A-25A 3 pin plug top,drain pipe, testing for satisfactory working without any abnormal noise/vibrations. Warranty shall be minimum 1 year for the complete machine and minimum 5 year for compressor. Scope of work also includes minor civil works such as cutting walls /making holes in wall/roof for refrigerant piping and electric cable, all accessories required for mounting/installation of indoor unit and outdoor unit i/c bracket/stand for outdoor unit, Supplying &laying of refrigerant piping (with pipe insulation) up-to 3 mtrs length and connecting between indoor unit and outdoor unit, nitrogen pressure testing and vacuumizing, charging with appropriate refrigerant i/c supplying additional quantities of refrigerant required etc. complete as required. However, Supplying of Voltage stabilizer is not included in this item. a) 1.5TR for cooling
Supplying 23 gauge wall thickness soft-annealed copper refrigerant pipes for suction & discharge (both) of suitable dia. as per recommendation of split ac unit manufacturer, laying & fixing on existing surface/cable tray or in recess in existing wall i/c chasing the wall and repairing to original finish, bending, cutting, jointing/brazing along with providing Class-0 tubular sleeves sections XPLE/closed cell elastometric nitrile rubber insulation including supports etc. complete as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .