Loading…
Loading…
Tender Value
₹3.9 Cr
EMD Value
₹7.9 L
Closing Date
29 Jun 2026, 3:00 pm2d left
Similar tender results from the same govt authority in the past 3 years.
TSK DIV:- Augmentation of Capacity of Running Room/ Rest Rooms at MXN & JTTN.
01-TSK-ENGG-25-2026
01-TSK-ENGG-25-2026
Open
12 Months
Unknown (Unspecified Location)
₹0
₹7.9 L
5 Jun 2026
5 Jun 2026
15 Jun 2026
Item- 1 CPWD items
S No. Item No Description of Item Unit Qty Rate Amount
1.0 CARRIAGE OF MATERIALS
By Mechanical Transport including loading,
unloading and stacking
1.1.18 Disposal of moorum/building rubbish/ malba/ cum 560 494.1 276696
similar unserviceable, dismantled or waste
material by mechanical transport including
1 loading, transporting, unloading to approved
municipal dumping ground for lead upto 10
km for all lifts, complete as per directions of
Engineer-in-charge.
2.0 EARTH WORK
2.1S General
Earth work in excavation by mechanical
means (Hydraulic excavator) / manual
means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on
2.8 plan), including dressing of sides and
ramming of bottoms, for all lift, including
getting out the excavated soil and disposal
of surplus excavated soil as directed, within
a lead of 50 m.
2.27 Supplying and filling in plinth with sand cum 400 2123.75 849500
3 under floors, including watering, ramming,
consolidating and dressing complete.
Surface dressing of the ground including
removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of
rubbish, lead up to 50 m and lift up to 1.5 m.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the
cost of centering and shuttering - All work up
to plinth level :
TINSUKIA DIVISION-ENGINEERING/N F RLY
derived from natural sources : 4 graded
stone aggregate 20 mm nominal size
derived from natural sources)
derived from natural sources : 8 graded
stone aggregate 40 mm nominal size
derived from natural sources)
4.10S DAMP-PROOF COURSE
4.12 Extra for providing and mixing water per bag 1200 18.15 21780
proofing material in cement concrete work in of 50 kg
doses by weight of cement as per cement
manufacturer's specification. used
5.0 REINFORCEMENT CEMENT CONCRETE
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 350 392.15 137252.5
for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies Sqm 470 927.25 435807.5
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 830 736.4 611212
bressummers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 750 961.3 720975
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Kg 18500 107.85 1995225
Fe-500D or more.
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above
5.22A.6 Thermo-Mechanically Treated bars of grade Kg 29700 107.85 3203145
Fe-500D or more.
5.33S DESIGN MIX CONCRETE
Providing and laying in position ready mixed
or site batched design mix cement concrete
for reinforced cement concrete work; using
coarse aggregate and fine aggregate
derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag
c e m e n t , admixtures in recommended
proportions as per IS: 9103 to accelerate /
retard setting of concrete, to improve
durability and workability without impairing
strength; including pumping of concrete to
site of laying, curing, carriage for all leads;
but excluding the cost of centering,
shuttering, finishing and reinforcement as
per direction of the engineer-in-charge, for
the following grades of concrete.:
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cum 150 9504.75 1425712.5
cement content of 330 kg /cum
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cum 250 9860.4 2465100
cement content of 330 kg /cum
6.0 MASONRY WORK
6.1S General
TINSUKIA DIVISION-ENGINEERING/N F RLY
Brick work with common burnt clay F.P.S.
6.1 (non modular) bricks of class designation 7.5
in foundation and plinth in:
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay
F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above
plinth level up to floor V level.
8.0 CLADDING WORK
8.1S General
Providing and fixing 18 mm thick gang saw
cut, mirror polished, premoulded and
prepolished, machine cut for kitchen
platforms, vanity counters, window sills,
facias and similar locations of required size,
approved shade, colour and texture laid
8.2 over 20 mm thick base cement mortar 1:4 (1
cement : 4 coarse sand), joints treated with
white cement, mixed with matching
pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete
Granite stone slab colour black, Cherry/Ruby
Providing edge moulding to 18 mm thick
marble stone counters, Vanities etc.,
8.3 including machine polishing to edge to give
high gloss finish etc. complete as per design
approved by Engineer-in-Charge.
8.5 Extra for providing opening of required size Each 2 978.7 1957.4
& shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar
20 location in marble/ Granite/ stone work,
including necessary holes for pillar taps etc.
including moulding, rubbing and polishing of
cut edges etc. complete.
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic Sqm 282 1267.95 357561.9
glazed wall tiles conforming to IS: 15622
(thickness to be specified by the
manufacturer), of approved make, in all
colours, shades except burgundy, bottle
green, black of any size as approved by
21 Engineer-in-Charge, in skirting, risers of
steps and dados, over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white
cement mixed with pigment of matching
shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing and fixing panelling or panelling
and glazing in panelled or panelled and
glazed shutters for doors, windows and
clerestory windows (Area of opening for
panel inserts excluding portion inside
grooves or rebates to be measured).
Panelling for panelled or panelled and
glazed shutters 25 mm to 40 mm thick :
TINSUKIA DIVISION-ENGINEERING/N F RLY
9.7.7 Float glass panes
9.7.7.1 4 mm thick glass pane (weight not less than Sqm 135 2241.8 302643
9.7.7.2 5.0 mm thick glass panes (weight not less Sqm 15 2600.45 39006.75
than 12.50 kg/sqm).
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
9.20 construction with frame of 1st class hard
wood and well matched teak 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Sqm 65 3473.85 225800.25
Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board
9.21 construction with frame of 1st class hard
wood and well matched commercial 3 ply
veneering with vertical grains or cross bands
and face veneers on both faces of shutters:
9.21.3 25 mm thick (for cupboard) including ISI Sqm 7.2 2093.7 15074.64
25 marked nickel plated bright finished M.S.
piano hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing chromium plated brass
curtain rod having wall thickness of 1.25mm
9.46 with two chromium plated brass brackets
fixed with C.P. brass screws and PVC sleeves
etc., wherever necessary complete :
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
9.53 Providing 40x5 mm flat iron hold fast 400 Each 120 228.85 27462
mm long including fixing to frame with 10
mm diameter bolts, nuts and wooden plugs
28 and embedding in cement concrete block
300x100x150 mm 1:3:6 mix (1 cement : 3
coarse sand : 6 graded stone aggregate 20
mm nominal size).
9.55S BRIGHT FINISHED M.S. FITTINGS
Providing and fixing ISI marked IS:1341 M.S.
9.55 pressed butt hinges bright finished with
necessary screws etc. complete :
COPER OXIDISED MILD STEEL FITTINGS
(COPPER OXIDISED AS PER IS: 1378)
Providing and fixing ISI marked oxidised M.S.
9.62 sliding door bolts with nuts and screws etc.
complete (Copper oxidised as per IS 1378)
Providing and fixing ISI marked oxidised M.S.
tower bolt black finish, (Barrel type) with
necessary screws etc. complete (Copper
oxidised as per IS 1378)
Providing and fixing ISI marked oxidised M.S.
handles conforming to IS:4992 with
necessary screws etc. complete (Copper
oxidised as per IS 1378)
TINSUKIA DIVISION-ENGINEERING/N F RLY
9.72S BRASS FITTINGS
9.82 Providing and fixing bright finished brass Each 30 121.65 3649.5
33 hanging type floor door stopper with
necessary screws, etc. complete.
9.84 Providing and fixing aluminium extruded Each 30 983.15 29494.5
section body tubular type universal hydraulic
door closer (having brand logo with ISI, IS :
3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from 701
mm to 1000 mm), with double speed
adjustment with necessary accessories and
screws etc. complete.
9.88S CHROMIUM PLATED BRASS FITTINGS
Providing and fixing chromium plated brass
9.92 handles with necessary screws etc.
9.105S GYPSUM BOARD PARTITIONS
Providing and fixing factory made uPVC
glazed/wire mesh windows/ doors
comprising of lead free uPVC multi-
chambered frame, sash and mullion/coupler
(where ever required) extruded profiles
having minimum wall thickness of 1.70 mm
for Series R1 and R2 profiles and 2.10 mm
for Series R3 and R4 profiles conforming to
EN: 12608 in any shape, colour and design
duly reinforced with galvanized mild steel
section made of required shape & size as
per CPWD Specification, uPVC extruded
glazing beads, interlocks and Inline sash
adaptor (where ever required) of appropriate
dimension, EPDM gasket, hardware, SS 304
grade fasteners of minimum 8 mm dia with
countersunk head, comprising of matching
polyamide PA6 grade sleeve for fixing frame
to finished wall as per IS 1367 : Part 1 to 14,
plastic packers, plastic caps and necessary
stainless steel screws etc. Profile of frame,
sash & mullion (if required) shall be mitred
cut and fusion welded/mechanically jointed
duly sealed at all corners, including drilling
of holes for fixing hardware and drainage of
water etc. After fixing frame the gap
between frame and adjacent finished wall
shall be filled with weather proof silicon
sealant over backer rod of approved size
and quality, all complete as per approved
drawing conforming to CPWD specification &
direction of Engineer-in-Charge. Section of
steel reinforcement and cross sections of
uPVC profiles to be as per design approved
by Engineer-in-Charge. Wire mesh / Glazing
of plain/ toughened/ laminated/ double glass
unit with / without high performance
coatings as per design requirements and
conforming to IS: 3548 & IS: 16231 shall be
paid separately.
Two track two panels sliding window with
9.147.A1 Aluminium channel for roller track, wool pile,
nylon rollers with SS 304 body.
9.147.A1.1 Using R2 series with frame (40 mm & above) Sqm 36 8298.85 298758.6
x (40 mm & above) & sash (25 mm & above)
36 x (50 mm & above) with zinc alloy (zamak)
powder coated touch locks with hook (Height
upto 1.2 metre).
TINSUKIA DIVISION-ENGINEERING/N F RLY
Three track three panels sliding window with
two glazed & one wire mesh panels with
Aluminium channel for roller track, wool pile,
nylon rollers with SS 304 body.
9.147.A4.1 Using R2 series with frame (70 mm & above) Sqm 36 10993.55 395767.8
x (40 mm & above) & both glazed and fly
screen sash (25 mm & above) x (50 mm &
above) with zinc alloy (zamak) powder
coated touch locks with hook. (Height upto
Fixed window / ventilator with mullion /
9.147.C2.1 Using R1 series with frame (33mm & above ) Sqm 75.6 9155.2 692133.12
x (35mm & above) & mullion (33mm &
above) x (50mm & above). (Height upto 0.90
10.0 STEEL WORK
10.1S General
10.2 Structural steel work riveted, bolted or Kg 12500 133.7 1671250
welded in built up sections, trusses and
39 framed work, including cutting, hoisting,
fixing in position and applying a priming
coat of approved steel primer all complete.
Steel work in built up tubular (round, square
or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing in
10.16 position and applying a priming coat of
approved steel primer, including welding and
bolted with special shaped washers etc.
10.28 Providing and fixing stainless steel ( Grade Kg 650 772.4 502060
304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding,
buffing, polishing and making curvature
(wherever required) and fitting the same
with necessary stainless steel nuts and bolts
complete, including fixing the railing with
necessary accessories & stainless steel dash
fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the
side of waist slab with suitable arrangement
as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless
steel members shall be considered excluding
fixing accessories such as nuts, bolts,
fasteners etc.).
11.0 FLOORING
11.1S General
Cement concrete flooring 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the
cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 450 614.2 276390
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including
finishing complete.
11.16S TILE FLOORING
TINSUKIA DIVISION-ENGINEERING/N F RLY
Chequered precast cement concrete tiles 22
mm thick in footpath & courtyard, jointed
with neat cement slurry mixed with pigment
11.20 to match the shade of tiles, including
rubbing and cleaning etc. complete, on 20
mm thick bed of cement mortar 1:4 (1
cement: 4 coarse sand).
44 11.20.4 Ordinary cement without any pigment Sqm 280 1056.35 295778
11.41S VITRIFIED FLOOR TILES
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by
the manufacturer) with water absorption less
than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick
cement mortar 1:4 (1 cement: 4 coarse
sand) jointing with grey cement slurry @3.3
kg/sqm including grouting the joints with
white cement and matching pigments etc.
The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be
done with the notch trowel, plier, wedge,
clips of required thickness, leveling system
and rubber mallet for placing the tiles gently
Double charge vitrified tile polished finish of
Glazed Vitrified tiles Matt/Antiskid finish of
Providing and laying Polished Granite stone
flooring in required design and patterns, in
linear as well as curvilinear portions of the
building all complete as per the architectural
drawings with 18 mm thick stone slab over
20 mm (average) thick base of cement
11.56 mortar 1:4 (1 cement : 4 coarse sand) laid
and jointed with cement slurry and pointing
with white cement slurry admixed with
pigment of matching shade including
rubbing , curing and polishing etc. all
complete as specified and as directed by the
Engineer-in-Charge.
11.56.1 Polished Granite stone slab colour of Black, Sqm 140 4481.3 627382
Cherry/Ruby Red or equivalent
12.0 ROOFING
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes.
Providing and fixing on wall face
unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain
12.42 water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming
to IS : 5382, leaving 10 mm gap for thermal
12.42.3 Single tee with door
12.42.5 Bend 87.5 degree
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing unplasticised -PVC pipe
clips of approved design to unplasticised -
PVC rain water pipes by means of 50x50x50
mm hard wood plugs, screwed with M.S.
screws of required length, including cutting
brick work and fixing in cement mortar 1:4
(1 cement : 4 coarse sand) and making good
the wall etc. complete.
Providing and fixing false ceiling at all height
including providing and fixing of frame work
made of special sections, power pressed
from M.S. sheets and galvanized with zinc
coating of 120 gms/sqm (both side inclusive)
as per IS : 277 and consisting of angle cleats
of size 25 mm wide x 1.6 mm thick with
flanges of 27 mm and 37 mm, at 1200 mm
centre to centre, one flange fixed to the
ceiling with dash fastener 12.5 mm dia x 50
mm long with 6 mm dia bolts, other flange
of cleat fixed to the angle hangers of
25x10x0.50 mm of required length with nuts
& bolts of required size and other end of
angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick
bottom wedge of 80 mm with tapered
flanges of 26 mm each having lips of 10.5
mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips
made out of 2.64 mm dia x 230 mm long
12.45 G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm
long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at
450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing
of gypsum board to ceiling section and
perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush
finish of tapered and square edges of the
board with recommended jointing compound
, jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm
on both sides of joint and two coats of
primer suitable for board, all as per
manufacturer's specification and also
including the cost of making openings for
light fittings, grills, diffusers, cutouts made
with frame of perimeter channels suitably
fixed, all complete as per drawings,
specification and direction of the Engineer in
Charge but excluding the cost of painting
12.45.1 12.5 mm thick tapered edge gypsum plain Sqm 450 1355.8 610110
53 board conforming to IS: 2095- (Part I) :2011
(Board with BIS certification marks)
TINSUKIA DIVISION-ENGINEERING/N F RLY
12.50 Providing and fixing precoated galvanised Sqm 450 738.65 332392.5
iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) of total coated thickness 0.50 mm
(base metal of minimum 0.45 mm thickness
with total coating thickness of 0.05 mm) with
zinc coating 120 grams per sqm as per IS:
277, in 240 mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet
54 should have protective guard film of 25
microns minimum to avoid scratches during
transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins,
rafters and trusses and including cutting to
size and shape wherever required.
Providing and fixing precoated galvanised
steel sheet roofing accessories of total
coated thickness 0.50 mm (base metal of
minimum 0.45 mm thickness with total
coating thickness of 0.05 mm) with Zinc
coating 120 grams per sqm as per IS: 277, in
240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and
polyester top coat 15-18 microns using self
drilling/ self tapping screws complete :
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
CEMENT PLASTER WITH A FLOATING COAT
12 mm cement plaster finished with a
floating coat of neat cement of mix :
13.16S 6 mm CEMENT PLASTER
13.16 6 mm cement plaster of mix :
13.20S PEBBLE DASH PLASTER
13.26 Providing and applying plaster of paris putty Sqm 3000 262.7 788100
of 2 mm thickness over plastered surface to
prepare the surface even and smooth
13.37S INTERIOR FINISHING
Distempering with 1st quality acrylic
distemper (ready mixed) having VOC
content less than 50 gram/litre, of approved
manufacturer and of required shade and
colour all complete to achieve even shade
13.41.1 New work (two or more coats) over and Sqm 1000 185.65 185650
including water thinnable priming coat with
cement primer having VOC content less than
13.44S EXTERIOR FINISHING
Finishing walls with Acrylic Smooth exterior
paint of required shade :
TINSUKIA DIVISION-ENGINEERING/N F RLY
13.46.1 New work (Two or more coat applied @ 1.67 Sqm 1500 160.6 240900
ltr/10 sqm over and including priming coat
of exterior primer applied @ 0.90 litre/10
Painting with synthetic enamel paint of
13.62 approved brand and manufacture of
required colour to give an even shade :
13.62.1 Two or more coats on new work over an Sqm 500 226.25 113125
64 under coat of suitable shade with ordinary
paint of approved brand and manufacture
Lettering with black Japan paint of approved letter
brand and manufacture per cm
16.0 ROAD WORK
16.1S ROADS
Dry brick pitching half brick thick in drains
16.12 including supply of bricks and preparing the
surface complete :
modular) bricks of class designation 7.5
17.0 SANITARY INSTALLATIONS
17.1S General
Providing and fixing water closet squatting
pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level
white P.V.C. flushing cistern, including flush
17.1 pipe, with manually controlled device
(handle lever) conforming to IS : 7231,with
all fittings and fixtures complete, including
cutting and making good the walls and floors
wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan Each 15 6767.4 101511
67 of size 580x440 mm with integral type foot
Providing and fixing white vitreous china
pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level
white P.V.C. flushing cistern, including flush
17.2 pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with
all fittings and fixtures complete, including
cutting and making good the walls and floors
wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic Each 15 6515.55 97733.25
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32
mm C.P. brass waste of standard pattern,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.7.2 White Vitreous China Wash basin size Each 30 2226.35 66790.5
69 630x450 mm with a single 15 mm C.P. brass
Providing and fixing Stainless Steel A ISI 304
(18/8) kitchen sink as per IS:13983 with C.I.
brackets and stainless steel plug 40 mm,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.10.2 Kitchen sink without drain board
17.22 Providing and fixing G.I. inlet connection for Each 35 142.85 4999.75
flush pipe connecting with W.C. pan.
TINSUKIA DIVISION-ENGINEERING/N F RLY
17.22B Providing and fixing CP Brass Single lever Each 30 6940.75 208222.5
telephonic wall mixer of quality and make as
approved by Engineer in charge.(a) 15 mm
Providing and fixing P.V.C. waste pipe for
17.28 sink or wash basin including P.V.C. waste
fittings complete.
17.28.1 Semi rigid pipe
Providing and fixing mirror of superior glass
(of approved quality) and of required shape
17.32 and size with plastic moulded frame of
approved make and shade with 6 mm thick
hard board backing :
17.34 Providing and fixing toilet paper holder :
17.71 Providing and fixing PTMT liquid soap Each 30 168.35 5050.5
container 109 mm wide, 125 mm high and
112 mm distance from wall of standard
shape with bracket of the same materials
with snap fittings of approved quality and
colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail
complete with brackets fixed to wooden
17.73 cleats with CP brass screws with concealed
fittings arrangement of approved quality and
17.73.2 600 mm long towel rail with total length of Each 30 708.95 21268.5
77 645 mm, width 78 mm and effective height
of 88 mm, weighing not less than 190 gms.
17.74 Providing and fixing PTMT shelf 440 mm Each 30 713.2 21396
long, 124 mm width and 36 mm height of
approved quality and colour, weighing not
less than 300 gms.
18.0 WATER SUPPLY
18.7S C.P.V.C. PIPES
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, and all
CPVC plain & brass threaded fittings,
including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement
and testing of joints complete as per
direction of Engineer in Charge. ( Internal
work - Exposed on wall )
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply,
including all CPVC plain & brass threaded
fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent
cement and the cost of cutting chases and
making good the same including testing of
joints complete as per direction of Engineer
in Charge. Concealed work, including cutting
chases and making good the walls etc.
18.15S BRASS FITTINGS
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing brass bib cock of
approved quality :
Providing and fixing gun metal gate valve
18.17 with C.I. wheel of approved quality (screwed
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
Providing and fixing uplasticised PVC
connection pipe with brass unions :
18.21.2 45 cm length
Providing and fixing C.P. brass shower rose
with 15 or 20 mm inlet
C.I. SLUICE VALVES/ FIRE HYDRANTS &
18.48 Providing and placing on terrace (at all floor Per 10000 11 110000
levels) polyethylene water storage tank, IS : Litre
12701 marked, with cover and suitable
89 locking arrangement and making necessary
holes for inlet, outlet and overflow pipes but
without fittings and the base support for
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass stop cock
18.52 (concealed) of standard design and of
approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve
18.53 for basin mixer and geyser points of
approved quality conforming to IS:8931
19.0 DRAINAGE
19.1S STONE WARE PIPES AND FITTINGS
Constructing brick masonry manhole in
cement mortar 1:4 ( 1 cement : 4 coarse
sand ) with R.C.C. top slab with 1:1.5:3 mix
(1 cement : 1.5 coarse sand (zone-III) : 3
graded stone aggregate 20 mm nominal
size),foundation concrete 1:4:8 mix (1
cement : 4 coarse sand (zone-III) : 8 graded
stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat of neat cement
and making channels in cement
concrete1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal
size) finished with a floating coat of neat
cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep
including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total
weight of cover and frame to be not less
than 38 kg (weight of cover 23 kg and
weight of frame 15 kg) :
modular) bricks of class designation 7.5
TINSUKIA DIVISION-ENGINEERING/N F RLY
Making soak pit 2.5 m diameter 3.0 metre
deep with 45 x 45 cm dry brick honey comb
19.32 shaft with bricks and S.W. drain pipe 100
mm diameter, 1.8 m long complete as per
standard design.
19.32.1 With common burnt clay F.P.S. (non Each 2 26861.9 53723.8
modular) bricks of class designation 7.5
21.0 ALUMINIUM WORK
21.1S General
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate
with double spring mechanism and door
weight upto 125 kg, for doors, including cost
21.4 of cutting floors, embedding in floors as
required and making good the same
matching to the existing floor finishing and
cover plates with brass pivot and single
piece M.S. sheet outer box with slide plate
etc. complete as per the direction of
Engineer-in-charge.
21.4.1 With stainless steel cover plate minimum Each 4 2823.85 11295.4
1.25 mm thickness
22.0 WATER PROOFING
22.1S General
22.5 Providing and laying water proofing Sqm 156 617.05 96259.8
treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry
mixed with water proofing cement
compound consisting of applying :(a) First
layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement
compound @ 0.253 kg/ sqm. This layer will
be allowed to air cure for 4 hours.(b) Second
layer of slurry of cement @ 0.242 kg/sqm
mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will
be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate
includes preparation of surface, treatment
and sealing of all joints, corners, junctions of
pipes and masonry with polymer mixed
26.0 NEW TECHNOLOGIES AND MATERIALS
26.73S PREFAB/PRECAST TECHNOLOGY
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite)
solid door/window/Ceosetory windows &
other Frames/Chowkhat comprising of virgin
PVC polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and
non toxic additives (maximum toxicity index
of 12 for 100 gms) fabricated with miter
joints after applying PVC solvent cement and
screwed with full body threaded star headed
SS screws having minimum frame density of
750 kg/cum, screw withdrawal strength of
2200 N (Face) & 1100 N (Edge), minimum
compressive strength of 58 N/mm2, modulus
of elasticity 900 N/mm2 and resistance to
spread of flame of Class A category with
property of being termite/borer proof,
water/moisture proof and fire retardant and
fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length
complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash
fasteners shall be paid for separately).
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite)
solid plain flush door shutter of required size
comprising of virgin polymer of K value 58-
60 (Suspension Grade), calcium carbonate
a n d natural fibers (wood powder/ rice
husk/wheat husk) and non toxic additives
(maximum toxicity index of 12 for 100 gms)
having minimum density of 650 kg/cum and
screw withdrawal strength of 1800 N (Face)
& 900 N (Edge), minimum compressive
strength 50 N/mm2, modulus of elasticity
850 N/mm2 and resistance to spread of
flame of Class A category with property of
being termite/borer proof, water/moisture
proof and fire retardant and fixing with
stainless steel butt hinges of required size
with necessary full body threaded star
headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
STDwithPVCon29.01.2026.pdf
ATTACHMENT
ArbitrationAdvancecorrectionslip10.pdf
ATTACHMENT
JPOofCablecutting.pdf
ATTACHMENT
GCCACSno.11_compressed.pdf
ATTACHMENT
Systemimprovement1692973.pdf
ATTACHMENT
SpecialcontionAugmentationcapacity.pdf Tender document 6
ATTACHMENT
SpecialcontionAugmentationcapacity.pdf
ATTACHMENT
Download all tender documents and submit your bid