Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.2 L+₹2.9 L (11.5%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹37.8 L+₹12.5 L (49.2%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L3 | Rejected-Finance Not being L1 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
21 Oct 2024, 6:00 pmClosed
Garrison Engineer Avadi
Garrison Engineer , Muthapudupet, Avadi
REPAIR AND REPLACEMENT OF LOOP PANEL BOXES, BUS BAR CHAMBERS, UG CABLE AND CONNECTED WORK AT ARMY AREA INCLUDING ADDN ,ALTN OF DG SET PLATFORM AT MTTI AF STN UNDER GE AVADI
2024_MES_675970_1
8230/E8
Open Tender
Electrical and Maintenance Works
Item Rate
Garrison Engineer Avadi
As per Tender documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹79,000
Yes
29 Oct 2024
23 Sept 2024
23 Oct 2024
23 Sept 2024
21 Oct 2024
9 Oct 2024
23 Sept 2024 - 30 Sept 2024
Amount
Demolition of Brick work or stone / bounder masonry built in lime / cement mortar complete all as specified and directed
Demolition of unreinforced cement concrete in ground floors and paving n.exc 15 cm thickness complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B1 using graded stone aggregates as in walls, etaining walls, basement walls an dthe like any thickness above top of the footing including attached plasters and buttresses complete all as specified and directed
Formwork to faces of walls, retaining of walls, abutments, parapets and staircase railing, and similar work including attached pilasters, buttresses etc.. Vertical or to batter for rough finished surfaces all as specified and directed
Reinforced cement concrete (nominal mix) 1:2:4 type B1 using graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, and in shelves and the like complete all as specified and directed
100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregates as in floor complete all as specified and directed.
Formwork to edge of concrete flats, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening)
TMT steel bars 10mm dia and over cut of length bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and directed.
Rendering 10mm thick in CM 1:4 or fair faces of brick work or concrete surfaces finished even and fair without using extra cement completed all as specified and directed.
Preparation of new wall surfaces and applying three coats of Cement base paint on wall surfaces all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material(soil)not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches fine sieved excavated dry soil including spreading/leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed.
Material and labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5/4 in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable/OH line ACSR conductor of any type complete all as specified and as directed:- (Note: Earth work and connected items will be measured and paid separately under respective items of schedule)
10 sq mm 2 core
16 sq mm 4 core
25 sq mm 3.5/4 core
35 sq mm 3.5 Core
50 sq mm 3.5 Core
70 sq mm 3.5 Core
95 sq mm 3.5 Core
120 sq mm 3.5 Core
185 sq mm 3.5 Core
Removal of UNSV PCC/Steel pole and provision steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coats of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole etc complete all as specified and directed. (Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items)
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed.
M&L for PCC 1:3:6 type C1, (using 20 mm graded stone aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing all as specified and directed.
Material and labour for GI tubing light grade for cable protection 50 mm dia laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete all as specified and as directed.
Material and Labour for MCCB 63 amps ,4 pole 415 volts ,3 phase ,50 Hz AC, 16 KA breaking capacity. The MCCBs shall have spreader links and barriers as standard feature of manufacturer including taking down old unserviceable one complete all as specified and as directed.
All as per item No. 22 above but of capacity 100 amps, 25 Ka including taking down old unserviceable one complete all as specified and as directed.
All as per item No. 22 above but of capacity 160 amps, 36 KA including taking down old unserviceable one complete all as specified and as directed.
All as per Item No.22 above but of capacity 200 amps, 36 KA including taking down old unserviceable one complete all as specified and as directed.
All as per Item No.22 above but of capacity 250 amps, 36 ka including taking down old unserviceable one complete all as specified and as directed.
All as per Item No.22 above but of capacity 400 amps, 26 ka including taking down old unserviceable one complete all as specified and as directed.
Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 No
Supply and Fixing MCB,240V,10KA,'B' curve,single pole,current carrying capacity 6 Amps, suitable for fixing in SMC box for control street/flood lights and making connections including taking down the old one complete all as specified and as directed .
Supply and Fixing of pole mounted Sheet Moulded Compound(SMC) Box weather proof type with hinged type door off white color of Size 300x200x100 mm comprising of 1 No MCB 6A and 4 rows with terminals with bolt and nut and connecting up cables with aluminium terminal lugs complete fixed on pole with suitable clamps, bolts and nuts including taking down the old one complete all as specified and as directed.
All as per Item No.30 above but of 140x140x100 mm comprising of 1 No MCB 6A and 2 rows including taking down the old one complete all as specified and as directed.
Material and labour for 1100 volts grade heavy duty cable PVC insulated , PVC sheathed,fire resistant, round , copper conductor, 3 core industrial cable of size 1.50 sqmm including taking down the old one complete all as specified and as directed.
M&L for fixing in replacement of Aluminum Bus Bar having current rating 200 Amp duly insulated with colour coding RYB and Black all as specified and as directed including making holes on the bus bar for making necessary connections all as specified and as directed.
M&L for replacement of Angle Iron for fixing Panel body shall be fixed on iron angle frame of size 40x40x5mm 40 cm grouted in 1:2:4 type 1 PCC 20 mm graded and 40 cm above the ground level duly painted with two coat of synthetic enammelled black paint over a coat of red oxide primer all as specified and directed
Supply & fixing in replacement Ammeter meter 100x100mm 0-100 amps of CT ratio 100/5, Digital type volts includind all electrical connection complete and specified
Supply & fixing in replacement Voltmeter meter 100x100mm 0-500 Volts, DIgital type volts in cludind all electrical connection complete and specified and directed.
Supply and laying in replacement of synthatic insulating mat of size 2mtr x 1mtr x 2 mm all as specified and directed.
S&F in repairs for 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages approx 2.0 mtr height and fixed with flat iron/angle iron by welding in position and directed complete all as specified and directed. Note:- MS angle, MS flats, Nuts, Bolts and washer will be measured and paid separatly under relevant items.
M & L for preparation of surfaces and applying two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs for MS work of angle iron channels and iron flats for post and struts of fencing around Transformer/Panel Boards etc drilling holes, flat iron for securing wire mesh by welding to angle iron frame and framed work as in door/ gate of angle and wire mesh door to be fixed by 02 Nos 100mm long hinges and one sliding door with nut and bolts for locking arrangement complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
All as per Item No.42 above but using galvanised iron strip 32×6mm as earthing lead complete
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron wire complete all as specified and directed
All as per Item No.44 above but 32x6mm galvanised iron strip complete all as specified and directed.
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/eqpts using GI nut, bolts & washer complete all as specified & directed
S&F in repairs for informatory/eqpt history sign boards of size not less than 900 x 600 mm rectangular type with 2 mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history details(i.e. Name, Make, Ser No,capacity of eqpt, vintage, SM/MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete all as specified and directed.
PSK Enterprises (BID ID -3145565)
NAVEEN ENTERPRIESES (BID ID -3138666)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .