Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹41.7 L+₹77,430.86 (1.89%)Rejected-AOC RANGAPAHAR CROSSING RAILWAY GATE NO 1 DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-AOC Quoted amount are higher than L1 | |
| 3 | L3₹41.9 L+₹98,944 (2.42%)Rejected-AOC | L3 | Rejected-AOC Quoted amount are higher than L1 | |
| 4 | L4₹42.5 L+₹1.6 L (3.94%)Rejected-AOC | L4 | Rejected-AOC Quoted amount are higher than L1 | |
| 5 | L5₹42.5 L+₹1.6 L (4.00%)Rejected-AOC | L5 | Rejected-AOC Quoted amount are higher than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR MAINT OF OLD LT OH LINES UG CABLES MCCBs LT POLES PAINTING WITH ALL ACCESSORIES
2024_MES_650271_1
8717/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
RANGAPAHAR
Class D
Category b (i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹80,000
23 May 2024
17 Apr 2024
8 May 2024
17 Apr 2024
6 May 2024
30 Apr 2024
17 Apr 2024 - 24 Apr 2024
Amount
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out etc complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil etc complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point etc complete all as specified and as directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation etc complete all as specified and as directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable for protection of electric cable etc complete all as specified and as directed.
Supply & laying GI tubing 'light grade' galvanised, with all fittings, fixed to walls, poles, ceilings complete for protection of cables of size 40 mm dia bore including taking out unsv GI tubing etc complete all as specified and as directed. Make:- Jindal/TATA/Prakash surya
Supply and laying or fixing or passing through pipe, LT XLPE insulated armured heavy duty cable 1100 volt grade ISI marked with aluminium conductor multi stranded cross sectional area 10 sq mm 2 core etc complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 6 sq. mm 2 core etc complete all as specified and as directed. Note:- (i) all connections are uniformally dressed and connected/ jointing of cable with suitable size of lugs.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 4 sq. mm 2 core etc complete all as specified and as directed.
Supply and fixing two core FRLSH PVC insulated stranded aluminium conductor cable of size 2.5 sq mm, 1100 volts grade ISI marked etc complete all as specified and as directed.
S&F in replacement of LED street light fitting driver ISI marked of capacity 60 Watt as per sample etc complete all as specified and as directed.
S&F in replacement of LED street light fitting driver ISI marked of capacity 70 Watt as per sample etc complete all as specified and as directed.
S&F in replacement of LED street light fitting driver ISI marked of capacity 90 Watt as per sample etc complete all as specified and as directed.
S&F in replacement of LED street light fitting driver ISI marked of capacity 120 Watt as per sample etc complete all as specified and as directed.
Supply and fixing in replacement of Rigid non-metallic PVC conduit 20mm medium grade ISI marked fixed to the pole by using suitable size of clamps, nuts bolts and washers for drawing of service connection wire for electric installation as per IS 9537 part 3 etc complete all as specified and as directed.
S & F PVC street light junction boxes of size 380mmx225mmx140mm with front openable shutter and locking arrangement with onesuitable size rating 6-32 Amps MCB, mounted on dwin rail, connectors including fixing to pole with MS flat iron clamp 25mm x 3mm size with nuts and bolts washers, etc. complete including taking down unserviceable one etc complete all as specified and as directed.
Material and labour for GI bracket for fixing of street light fitting , made out of 40 mm bore GI pipe,light grade of length not less than 1.20 mtr,45 degree bend to shape and fixed on pole with 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts &washers including taking out old unsv bracket etc complete all as specified and as directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing, heat resistant, corrosion resistantcomplete with driver, suitable size of bracket incl nuts, bolts, washers etc including thermal management in multiple optics with IP 65/66 protection complete. Including taking down old unsv light fittings etc complete all as specified and as directed.
All as per item No 18 (here-in-before) but cap 70 watts.
All as per item No 18 (here-in-before) but cap 90 watts.
All as per item No 18 (here-in-before) but cap 35 watts.
Material and labour in replacement of unsv LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics, environmental friendly,corrosion resistant, and equipped with IP66 protection complete with driver and lamp suitable for tower lights as application including openign and fixing of nuts, bolts and washers on existing high mast/tower/wksp structure properly etc complete all as specified and as directed.
M & L for replacement of MCB SP-240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete all as specified and as directed.
All as per item No 23 (here-in-before) but MCB SPN 32 Amp, 240 volts 10 KA.
M & L for Steel tubular swaged poles Type 410-SP-31 (9 meter Long) including cast iron base plate finial tapper plug, bolts, cap, mild steel bolts, nuts and screws etc including applying two coats of black bituminous paint internally and externally up to planting depth and applying two coats of aluminium paints over acoat of aluminium primer (externally from top of PCC coping) confirming to IS 2713-1980 complete all as specified and as directed. (Earth work and concrete foundation shall be measured and paid separately under relevant items of Sch 'A') .
M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for pole foundation etc complete all as specified and as directed.
M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work etc complete all as specified and as directed.
SHRI MADAN SINGH
M/S Lucky Builders
commercial enterprises
das enterprises
VAISHNO ASSOCIATES
M/s K P Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .