Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.3 L+₹3.5 L (14.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.4 L+₹8.7 L (36.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR/ REPLACEMENT OF OLD RUSTED PIPE LINE, VALVES AND CONNECTED ACCESSORIES IN THE AOR OF AGE B/R-II UNDER GE 881 EWS
2024_MES_665702_1
GE/PNH-31/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹80,000
Yes
25 Jan 2025
12 Jul 2024
19 Sept 2024
12 Jul 2024
12 Sept 2024
26 Jul 2024
Amount
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for taking up or laying pipe in any type of soil and getting out complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and ramming in layers not exceeding 25 cm without damaginlg pipes specials/CI specials, fittings complete all as specified and directed.
Removing of surplus spoil not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 m above the strating point complete all as specified and directed.
S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete laid in trenches, in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
150 mm dia
S&F in repair Gate / globe valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed for following size:-
20 mm bore.
25 mm bore.
40 mm bore
50 mm bore
M&L for construction of brick masonry valve pits of size 100 cm x 100 cm x 105 cm (internal dimension) complete including fabrication of mild steel cover made out of 3 mm thick MS sheet and angle iron frame made out of 40 mm x 40 mm x 6 mm thick and one side provided with hinges and another side provided with locking arranement as per TD drawing held in the office of Engg-in-charge including dismantling the existing unserviceable valve pit complete all as specifeid and directed.
All as per item No 7 above but size 90cm x 90cm x 90cm (internal dimension) complete all as specified and directed.
S&F in repair sluice valve 150mm bore, conforming to IS -14846-2000 PN 1.6 with Steel metal spindle, both ends flanged and drilled with necessary holes for bolts including jointing materials viz nuts, bolts, rubber gaskets etc with iron wheel head including flange joints and making necessary arrangements to fix in position, complete all as specified and directed .
All as per Srl item No. 9 above but 100 mm bore complete all as specified and directed.
All as per Srl item No. 9 above but 80 mm bore complete all as specified and directed.
S&F in repair cast iron reflux valve 150 mm bore, with by pass arrangement, complete all as specified and directed
All as per Srl item No. 12 above but 100 mm bore complete all as specified and directed.
All as per item No. 12 above but 80 mm bore complete all as specified and directed.
All as per item No. 12 above but 50 mm bore complete all as specified and directed.
S&F in repair Cast iron Air Release Valve 150mm bore, with two air outlets complete all as specified and directed
All as per Srl item No. 16 above but 100 mm bore complete all as specified and directed.
All as per Srl item No. 16 above but 80 mm bore complete all as specified and directed.
Supply only chlorination chemical highly efficient (high strength) calcium hypochloride 65% to 70% chlorine content based granular disinfectant more stable in sealed container, no sodium/ iron/ mercury/ heavy metal contaminations, complete all as specified and directed. Note: (i) The contractor shall produce manufacturer's test certificate and purchase vouchers of calcium based granular disinfectant. (ii) Qty shown at column D will not accepted at one time as the material having lesser expiry period. (iii) The calcium based granular disinfectant shall be brought at site in sealed plastic container. (iv) Calcium based granular disinfectant shall be of approved make as approved by E-in-C's branch or HQ CENC.
S&F in repair MS nuts, bolts with washer of any dia and any size as per existing at site complete all as specified and directed.
S&F in repair neoprene rubber gasket suitable for flanges upto 150mm dia pipe not less than 3mm thick of any dia and any size as per existing at site complete all as specified and directed.
S&F in repair CI foot valve of dia 100mm ISI marked with all fittings complete all as specified and directed.
S&F in repair CI foot valve of dia 80mm ISI marked with all fittings complete all as specified and directed.
S&F in repair CI foot valve of dia 50mm ISI marked with all fittings complete all as specified and directed.
M&L for cutting of existing pipe and making arrangements for insertation of NRV and including replacement of NRV of 80/100 mm bore (PN 1.6) and including flanged joint with 3mm thick neoprene rubber gasket including necessary bolts and nuts and necessary earth work complete all as specified and directed.
S&F in repair CI/DI flanged fittings like bends (any radius and angle) tappers any type (straight, bend, increasing, decreasing or double socket), Tee pieces single branch, "Y" junction, double branch, cross (all socket or socket spigot) collars, caps, caps & plug for pipes with spigot or flanged end of any size complete all as specified and directed.
S&F in repair of pressure gauge of 0-150 Psi for 4" dia size and capacity with necessary accessories for fixing complete all as specified and directed.
S&F in repair of old unsv gland packing with new to the valves/pumps sets etc of any sizes/capacity complete with neoprene rubber gasket, jointing material and including nuts/bolts/washers of suitable size complete all as specified and directed.
M&L for leakage rectification by pumping/bailing out of back flow accumulated water in trenches, cutting of existing pipe and making threading/ welding for repair/replacement of unsv fittings, rubber gasket, saddle pieces, nuts, bolts with washer etc, pipe in short lengths (upto 1.5 mtr) for addition and alteration upto 150mm dia CI/DI/MS pipe and including replacement of fittings, rubber gasket, saddle pieces, nuts, bolts with washers etc complete all as specified and directed. Note: Pipe in short lengths (upto 1.5 mtr), high density rubber sheet, welding work and necessary excavation and earth work as required for making it serviceable is deemed to be included in quoted rate.
M&L for PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregate, as in foundation filling and mass concrete for haunching of pipe of any size complete all as specified and directed.
M&L for replacement of dosing tank suitable for existing at site and as per recommended by manufacturer of declibac technology complete all as specified and directed by Engg-in-charge.
M&L for replacement of shaft with impellar of dosing pump suitable for existing at site complete all as specified and directed by Engg-in-charge.
M&L for replacement of coil 250V, 50 HZ suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of roller assembly, suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of pump tube, suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of injection check valve of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge
M&L for replacement of weighted suction line strainer of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of white suction/discharge tube of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of check valve suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of connecting nut of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of connecting nut with adapter of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of ferrule of size 1/4", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
M%L for chemical suitable for RO plant (chemical dosing pump) as recommended by manufacturer complete all as specified and directed by Engg-in-charge.
M&L for servicing of pressure sand filter plant complete in all respect including replacement of necessary parts if required and make it functional, including testing, complete all as specified and directed.
VIKAS ENTERPRISES (BID ID -3085968)
M/S PARSHOTAM KUMAR GUPTA (BID ID -3087020)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .