Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹28.8 L+₹94,774.50 (3.40%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹29.5 L+₹1.6 L (5.85%)Rejected-Finance NEAR MPEB OFFICE DHANA DISTT SAUGOR MP 470228 | DHANA | SAUGOR | MP | 470228 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹29.9 L+₹2.0 L (7.22%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹30.9 L+₹3.1 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹36.8 L
EMD Value
₹73,500
Closing Date
21 Nov 2023, 6:00 pmClosed
GE Saugor
GE Saugor
Spl repair to Bldg No DET-07 at 336 Fd Hospital under GE Saugor
2023_MES_624933_1
GE/SGR/TOK-54 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Saugor
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAUGOR
₹73,500
Yes
29 Dec 2023
25 Oct 2023
23 Nov 2023
25 Oct 2023
21 Nov 2023
9 Nov 2023
26 Oct 2023 - 1 Nov 2023
Amount
Dismantling of floor, hearth or wall tiles / terrazo /kota stone/interlocking tiles including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Dismantling framed trusses of span not exc 10m complete all as specified and directed.
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed.
Demolition PCC of any description and in any position unreinforced complete all as specified and directed.
Dismantling of wall ceiling board (fibre,pulp,insulation etc)or insulation board/slab/blankers,any thickness ,including cover fillets complete all as specified and directed.
Taking down cement plaster on brick wall including raking out,joints hacking for key's scrubbing down with water complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straright or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Excavation over areas , not exc 1.5 m deep and getting out soft/loose soil complete all as specified and directed.
M&L for approved earth filling with approved soil brought from out side MD land, filling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed.
M&L for hardcore of gauge not exc. 63 mm, broken stone or boulders deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 30 to 50 mm stone dust cushioning complete all as specified and directed.
M&L for polished machine cut Kota stone slab flooring 18mm to 20mm thick size not less than 550mmX550mm laid over and including 15mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
M&L for Kota stone slab 12mm to 15mm thick in skirting, steps riser etc over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
S&F GI ( cold rolled) snap grid size of 600mm x 600 mm frame work of 24 x 38 x 0.60 mm, Tee Section ( bottom pre coated ) and 24mm x 24mm x 0.5mm thick angle rung along the wall incl GI suspenders wire as per manufacturer instruction as in ceiling with and including S&F white non Asbestos designer ceiling cement boards 4 mm thick complete all as specified and directed.
M&L for PCC type B2, 1:2:4 (using 40 mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregates) as in , coping, benching and other similar work with weathering slightly rounded edges and throating etc as req with and incl all necessary form work complete all as specified and directed.
M&L for PCC 1:4:8, Type D2 (using 40 mm graded stone aggregates), 100mm thick, as in sub base complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregates) incl finished even and smooth with using extra cement as in plinth protection incl necessary form work to edges including filling of joints with bituminous compound complete all as specified and directed.
M&L for two coats cement plaster, first coat 15mm thick CM 1:4 on brick wall surfaces and second coat cement plaster 5mm thick in CM 1:4 mixed with WPC @ 2 % (Wt of cement qty) finished even and smooth without using extra cement complete all as specified and directed. Note:-WPC shall be measured and paid seperately under respective item
Supply only integral water proofing compound complete all as specified and directed.
M&L rendering 15 mm thick on surface other than fair face of brickwork with CM 1:6 finished even & fair complete all as specified and as directed
S&F chicken wire mesh 0.71mm dia and aparture size 25mm fixed in position complete all as specified and directed.
M&L for precast reinforced cement concrete type B1 (1:2:4) (using 20 mm graded stone aggregates) set in CM(1:4) in landings,kitchen platform, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed.
S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15mm bore GI tubing and connections and cutting and screwing to existing GI tubing for addition alteration complete all as specified and directed
S&F in repair vitreous China WHB white flat back size 550mmx400mm with full size pedastal including S&F angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but not exc 4 Sqm each complete all as specified and directed. .
S&F 105 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in P:C:C 1.2.4 type B-1 using 20 mm graded stone aggregate and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and as directed
S&F 35mm thick second class hardwood factory made plain framed, penelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per : IS 1003 (part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F secod class hardwood factory made 30mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (with sash bars any numbers), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, for windows and ventilator all as per SSR Part-I clause 8.24 (b)
S&F steel window with side hung shutters with glazing bars devetailed or welded, fixed on and including pressed steel frame of size 80mm x 40mm x 1.25mm thick CRCA profile section with box type hinges, steel handle, steel peg stay etc complete all as specified and directed.
S&F steel window with side hung shutters without glazing bars and fixed to steel frame complete all as specified and directed..
S&F galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200 mm complete all as specified and directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm complete all as specified and directed.
S&F Mild steel pressed handles,150mm oval type, stove enamelled black complete all as specified and directed.
S&F Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed complete all as specified and directed.
Cutting holes in brick walls in cement mortar or cement lime mortar and stone wall built in lime mortar for inserting holdfasts in exc. One brick but not exc. two brick wall and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
Refixing only roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats complete all as specified and directed. Note:-Steel truss obtained from Srl item No.3 here-in-before shall be re-used in this item.
S&F Steel work in tubular trusses/purlins/posts (of round/rectangula/square hollow section)including special shaped washer etc. complete using ERW or induction butt welded to base /bed plate complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, trapozoidal pattern with guard film of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding in wall, fixed with self tapping screws including dismantling old plain or corrugated asbestos sheeting , any gauge, thickness complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based modular sheet as in ridge 0.45mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding in wall, fixed with self tapping screws including dismantling old plain or corrugated asbestos sheeting , any gauge, thickness complete all as specified and directed.
S & F Mild Steel plates (Plain or chequred) channels, square cut or notched forming holes, with riveted, bolted, welded attachement conforming to Fe 410 - W (Gde-E-250) quality-B complete all as specified and directed
S & F MS screw bolts machine made with hexagonal or square heads at one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 16 to 20mm and length exc 22.5cm and n exc 30cm complete all as specified and directed
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290 Gde-E-165 complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed
M&L for coat of synthetic enamel paint including preparation of old steel surface of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed
M&L for two coat of synthetic enamel paint over a coat of red oxide primer including preparation new untreated steel of surface of any description, n exc 10 cm in width or girth for wind ties complete all as specified and directed
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M &L for applying three coats of white wash on new wall surface including preparation of surface complete all as specified and directed
M&L for applying two coats of synthetic Emulsion distemper, white or tinted over a coat of wall primer and applying Birla / J. K. wall care white putty 2mm thick for levelling the surfaces on new wall surface including preparation of surface complete all as specified and directed.
M & L for complete removal of existing treatment and applying Birla / J. K. wall care white putty 2mm thick for levelling the surfaces including properly making of 'V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of synthetic emulsion distemper over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed
M & L for applying two coats exterior weather coat ( ACE paint or equivalent) over one coat of exterior primer including preparation of surfaces of new walls etc complete all as specified and directed by Engr-in-charge. Make Asian ACE or equivalent make as specified in Appx 'C' Particular Specifications
M & L for complete removal of existing treatment and applying two coats exterior emulsion paint over one coat of exterior primer incl. preparation of surfaces of old decorated walls etc complete all as specified and directed by Engr-in-charge. Make Asian ACE or equivalent make as specified in Appx 'C' Particular Specifications
S&F mild steel work like flat iron including all necessary drilling,screwing, bolting , reveting & welding, etc and similar work conforming to Fe-290 Gde E-165 for wind ties,gutter strap and frame for cladding complete as specified and directed.
S&F in replacement 500 ltr capacity of rotational moulded polyethyline water storage tank (Cylindrical vertical with closed tape) three layered wall construction, ISI marked hoisted & fixed in position incl S&F 20mm dia GI Pipe medium grade washout pipe 450mm long with plug & 20mm dia GI pipe medium grade overflow pipe 600 mm long with fittings complete all as specified & as directed
S&F in repair PVC float valve assembly including assessories with float valve 20mm dia complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete as specified and directed
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds, mitered /stopped ends complete as specified and directed
Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor complete all as specified and directed
Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity complete all as specified and directed.
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FRLSH insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry complete all as specified and directed:-
One light, fan point controlled by one switch
One 5 Amp independent socket point controlled by one switch
One 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.67 here in before but for power point wiring using with 2.5 sqmm PVC-FR LSH insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed
S&F Modular switch, one way, 6 Amp 230, 1 module complete all as specified and directed
S&F socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed
S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt complete all as specified and directed
S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed
S&F ceiling rose, surface backlit,three terminal complete all as specified and directed
S&F Modular lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed
S&F modular fan step regulator 120W 2 module complete all as specified and directed
S&F LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED bulb 10 watt suitable for angle / batten holder fitting complete all as specified and directed
S&F ceiling fans complete with blades, down rods, with remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
M&L for concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC conduit size not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
All as per Srl item No.81 above but SPN 40 Amps, 240 V
S&F sheet metal enclosure DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar of suitable size complete all as specified and directed
S&F in replacement double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in the quoted rate
S&F in replacement TPN 63 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles complete all as specified and directed
Supply and laying cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 16 sqmm, 4 core complete all as specified and directed
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth for laying of cable as the case may be and getting out hard / dense soil complete all as specified and directed
M&L for sand cushioning in trenches for the cable complete all as specified and directed
Returning filling, spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated surplus material n. exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from starting point complete all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed
S&F in replacement of GI Pipe light grade 50 mm dia ISI marked on pole on wall or laid in trenches incl all fittings (nut, bolt, clamps & washers) complete all as specified and directed
M&L for provn of earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
PK CONSULTANT
siddhant construction
m/s mohansingh
v k builder
m/s mahendra kumar khare contractor
SAGAR MOTOR AND TRACTOR CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .