Tender Value
Refer Docs
EMD Value
₹66,780
Closing Date
10 Dec 2021, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
PROVN OF ONLINE 15 KVA UPS CEILING FANS HEAVY DUTY DESERT COOLER GEYSERS FOR 167 MH AND UNDERGROUND ELECTRIFICATION OF SECURITY LIGHTS OF PREMISES OF 616 AT DHANGU COMPLEX UNDER GE S PATHANKOT
2021_MES_487722_1
GES/PKT/T-26/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹66,780
Yes
18 Feb 2022
11 Nov 2021
13 Dec 2021
11 Nov 2021
10 Dec 2021
26 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. (cable shall be laid 60 cm below ground level )
All as per item No.1 above but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings, complete all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole, complete all as specified and directed.
Material and labour for replacement of GI tubing light grade 80 mm bore for passing through cables under the floor ,along the wall or along the pole, complete all as specified and directed
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor ,along the wall or along the pole, complete all as specified and directed
Material and labour earthing with steel earth plate electrode of size 60x 60cm x6mm thick buried directly in ground to a depth not less than 2.25m deep below normal ground level with top edge of the earth plate not less than 1.5m deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining, cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
120 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
25 Sqmm 4 Core
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws,type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A'
M&L plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete for the poles all as, complete all as specified and directed.
M&L plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete for the poles, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1, (using 20mm graded stone aggregate) for coping of poles including necessary form work complete all as specified and as directed.
Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens (72 watt) and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl GI bracket of size 40mm dia and 1.2 mtr long with necessary clamps etc complete and testing on completion all as specified and as directed.
S&F loop-in/loop-out box of internal size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable, complete all as specified and directed.
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square aluminium bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Supply, installation, testing and commissioning of online UPS for minimum 1 Hour back up suitable for three phase AC input 300 to 450V, 50 Hz supply and output 415 V ± 1%, 50 Hz ± 0.5% of capacity 15 KVA, CE Marked standards with the features such as Isolation Transformer Model UPS System, Double Conversion with IGBT Module, Micro Controller Based Design, Latest SPWM Technology, Instantaneous Voltage Controller,Pure Sine wave,Intelligent Microprocessor Control,High Input Voltage ,window,Extended run time capability, Cold start facility,Heavy Duty Charges, Compact size, Power factor>.95,Total Harmonic Distortion (THD) : <3%, Surge Protection , User friendly LCD display, High Efficiency,IP-20 or better, Audio/Visual alarm,UPS LCD/LED Display Indication for Input Voltage, Output Voltage, Battery Voltage, Output , Auto/Manual By pass switch etc complete with battery back up and battery rack with suitable Qty of SMF-VRLA 12V rated batteries of suitable AH for 15 KVA UPS and inter connecting copper cables complete. Note: 1.The rate inclusive of complete UPS with testing and commissioning complete. 2. Comprehensive warranty period will be for further two years after defect liability period of two years for entire UPS and batteries. 3.Any cost of replacement of spares of UPS and batteries during the warranty period is deemed to be included in the quoted rate. 4.The UPS should meet the EN 50091-1 & EN 50091-2 or equivalent IEC standards.
Supply and fix ON LOAD change over switch 415V, 50 Hz,4 pole of capacity 63 Amps in sheet steel enclosure made out of CRCA sheet duly powder coated of thickness 2mm with IP- 54 and LED indication lamps complete all as specified and directed.
S & F distribution board iron clad, double door with IP-54 IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Material, labour, testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ or 4 core with working voltage 1100 volts.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 4 sqmm multistrand in concealed conduit with 4 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 6 sqmm multistrand in concealed conduit with 6 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
Material and labour earthing with copper earth plate electrode of size 600 mm x600 mm x3.0 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected with 20 x 3 mm copper strip as earth lead electrode by means of nuts, bolts and washers, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply & fix Copper strip 20mm x 3mm complete with saddles and fixing screws for fitting the strip, complete all as specified and directed.
Supply and fixing ceiling fan of size 1200 mm sweep,copper wound ,5 star rating,opal white ,ISI marked , including fan regulator,fan blades, down rod and connected accessories complete all as specified and directed.
M&L for point wiring with PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches/ sockets/ regulators/ ceiling roses etc) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). Note: In ceiling Portion surface conduit wiring shall be carried out. One light point or one fan point or bell point controlled by one switch SP one way 230 Volts.
All as per item No. 35 above but One socket out let 5/6 Amps on Independent board.
M&L for switch socket combination single pole one way 5 amps 240 volts with polycarbonate body.
M&L for switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body.
M&L for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body.
Supply and installation,testing of water heater storage of capacity 25 Ltrs ,5 satr rating, including all accessories complete all as specified and as directed.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Supply & Fix sheet metal enclosure with DB's ( grouted in walls) single pole and neutral double door type for MCB's 08 ways with 200 Amps 240 volts rated bus bar all as specified and directed.
M&L 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'B' sereis, complete all as specified and directed.
S&F MCB 6 to 32 Amp SPN 50 C/S 10 KA 'B' sereis complete all as specified all as directed.
M&L for GI tubing medium grade of 15 mm dia complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked, complete all as specified and directed.
S&F stop valve, cast cooper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm dia of ISI Marked, complete all as specified and directed.
S&F pillar taps cast cooper alloy with capstan head CP screwed down high pressure, with or without lettered Hot or Cold of size 15mm dia of ISI Marked, complete all as specified and directed.
Install, test and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800 mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity 50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimum air Delivery- 4000 Cum/hr,approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPM rated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch with fan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including stand of minimum height 900 mm made out 25mmx25mmx3mm MS angle iron , duly coated with weather proof paint of black colour
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SATPAL AND BROTHERS
SATISH AND CO
M/s. Aggarwal Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .