| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.7 L+₹14,867.75 (1.02%)Rejected-Finance | L2 | Rejected-Finance Rejected BeingL2 | |
| 3 | L3₹15.3 L+₹72,569.05 (4.99%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Rejected BeingL3 | |
| 4 | L4₹18.6 L+₹4.0 L (27.5%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Rejected BeingL4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh c/o 56 APO
REPAIR/REPLACMENT TO SECURITY PERIPHERY ITS AND STREET ITS IN DOMESTIC AND TECHNICAL AREA AT AF STATION LEH UNDER GE (AF) LEH
2023_MES_589625_1
GE(AF)/LEH/T-14/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹40,000
Yes
28 Jun 2023
15 Apr 2023
18 May 2023
15 Apr 2023
15 May 2023
1 May 2023
Amount
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in any type of soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge.
All as per Item No. 1 here-in-above but depth exceeding 1.50 m & not exceeding 3m in depth , complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Sand cushioning to under ground cable with clean dry sand locally available with layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
Factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other in and including taking down old unservicable cable cover, complete all as specificed and directed by Engineer-in-Charge.
Relaying of factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm taken out while taking out old unserviceable cable, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specificed and directed by Engineer-in-Charge.
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 50 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable , complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 8 here-in-beforee but size 35 Sqmm 3.5 core
All as per item No 8 here-in-beforee but size 25 sqmm 3.5 core.
All as per item No 8 here-in-beforee but size 16 sqmm 4 core.
All as per item No 8 here-in-beforee but size 16 sqmm 2 core.
All as per item No 8 here-in-beforee but size 10 Sqmm 2 core.
Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
Steel tubular swaged poles type 410 SP-22 ( 8.5 metres long) complete with cast iron base plate, final, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint including dismantling of existing old damage PCC pole/ steel pole of any description , complete all as specified and as directed by Engineer in charge. Note :Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .
PVC insulated round sheathed industrial cable of size 1.5 Sqmm 2 core multi-stranded copper conductorfor connecting junction box to street light fitting in and including old unservicable cable , complete all as specified and directed by Engineer-in- Charge.
PVC conduit medium grade 25mm thick for running 2 core cable from junction box to street / flood light fitting including necessary fixing arrangement such as MS clamp of suitable size complete with nuts and bolts in and including taking down old unservicable conduit , complete all as specified and directed by Engineer-in- Charge.
Dismantling of old security light bracket including cutting and welding, if required, fixed to steel tubular pole at any height with electric connectin and refixing the security light with the same bracket on the same pole if bracket is unservicable than fixed the light with new brcket , complete all as specified and directed by Engineer-in-Charge. Notes :1.The old unserviceable bracket shall be sold the contractor under Schedule of Credit. 2. If new bracket is required for refixing of light in case of unservicable bracket than same shall be measured and paid separately under the respective item.
Street light bracket fitting made out of 40mm dia GI pipe light grade tubing 1.2 mtr long bent to required shape including 02 Nos of MS clamp of size 450x50x5mm flat duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc fixed in and including taking down old unservicable bracket , complete all as specified and directed by Engineer-in- Charge.
New generation energy saving and environmental friendly long life 150 watt LED flood light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source in & including taking down of old unserviciable light ,complete all as specified & directed by Engineer-in-Charge.
New generation energy saving and environmental friendly long life 60 watt LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source in & including taking down of old unserviciable light ,complete all as specified & directed by Engineer-in-Charge.
New generation energy saving and environmental friendly long life 70 watt LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source in & including taking down of old unserviciable light ,complete all as specified & directed by Engineer-in-Charge.
New generation energy saving and environmental friendly long life 30 watt LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source in & including taking down of old unserviciable light ,complete all as specified & directed by Engineer-in-Charge.
Decorative LED Post Top ideal 360 degree indirect light of capacity 40W complete including stand suitable as per OEM with IP65 protection, resistant to impact, anti corrosion, glarefree and better uniformity in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Thermoplastic cable junction boxes IP 55/65 with metric knockout for cable entry of size 200 x160x 98 mm fixing on pole / wall with MS clamps / MS flat iron ( as per site requirement) of size 25x4mm , nuts bolts and washer and glands, including one No of MCB SP 6 Amps in and including taking down old unserviceable boxes , complete all as specified and directed by Engineer-in- Charge.
MCB SP 6 to 32 Amps - 10KA 240 Volts as in replacment, complete all as specified and directed by Engineer-in- Charge.
Plain cement concrete ,1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates as in foundations of pole and filling of mass concrete, complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:4:8, type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations of pole and filling of mass concrete, complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:2:4 type B-1, using 20 mm graded mechanically crushed stone aggregates as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work for concrete eathing pit ,complete all as specfied and directed directed by Engineer-in-Charge.
Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,including dismanteling of old unserviceable earthing , complete all as specified and as directed by Engineer-in-Charge. Note : (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.
Labour only for dressing of existing LT panels with taking out the all (incoming & outgoing) cables loop from trench, cutting the damage piece, straight the cable and connect the same in panel with proper aluminium thimbles, complete all as specified and directed by Engineer-in-Charge. Note : If loop in any cable is not available then epoxy joint to be carriedout and the joint will be paid separately.
PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm in and including taking down of old unservicable cable, complete all as specified and directed by Engineer-in-Charge.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents.
Ms Salaria Builders
SUMEET TRADING CORPORATION
R B TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .