Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC Becomes L1 | |
| 2 | L2₹10.7 L+₹91,213 (9.34%)Rejected-Finance 63 SECTOR 4 R FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance Being not L1 bidder. |
Tender Value
₹10.5 L
Closing Date
20 Sept 2021, 6:00 pmClosed
AGM (E-E)-II
Airports Authority of India, Imphal Airport.
Replacement of Distribution Panels and Energy Meters in Residential Colony at Imphal International Airport
2021_AAI_87672_1
AAI/IMP/AGME (E)/eNIT-CW-05/2021-22
Open Tender
Electrical Works
Item Rate
90 days
Imphal
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
Exempted
9 Jun 2022
9 Sept 2021
22 Sept 2021
10 Sept 2021
20 Sept 2021
10 Sept 2021
10 Sept 2021 - 14 Sept 2021
Amount
Fabrication, S.I.T.C of Indoor MV Panel with Single door arrangement made out of 2mm thick outer sheet, dust tight, vermin proof, totally enclosed, cubicle type, floor mounting, free standing, suitable for operation at 433 V, 3 phase, 4 wire, 50 Hz, A.C. Power Supply System complete with all accessories, interconnection, connection, earthing, painting, grouting, providing pedastal UPTO THE HEIGHT OF 300 MM, Cable Entry provision etc. as required and comprising of following: 1.1 One No. of 100 A, 36 KA, 4P MCCBs with Microprocessor Based Releases for OC/SC/EF Protection as INCOMER with CT Operated MFM of Conserve Make Model EM6400 or Equivalent, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. 1.2 Two No. of 32 A, 25 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps as required. 1.3 Six Nos. 32 A, DP "C" curve, 10KA MCB for single phase supply, with Single Phase Electronic Energy Meter with LCD display of range 5-30A as required. 1.4 One Set of 150 Amps Al. Bus Bars with at Par Neutral BUS BARS as required. 1.5 All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required. ALL AS ABOVE 1.1 To 1.5
Fabrication, S.I.T.C of Outdoor MV Feeder Pillar Panel with double door arrangement made out of 3mm thick outer sheet and 2mm thick inner sheet and partition CRCA sheet steel, dust tight, vermin proof, totally enclosed, cubicle type WITH TOP CANOPY FOR RAIN PROTECTION, floor mounting, free standing, suitable for operation at 433 V, 3 phase, 4 wire, 50 Hz, A.C. Power Supply System complete with all accessories, interconnection, connection, earthing, painting, grouting, providing pedastal UPTO THE HEIGHT OF 450 MM, Cable Entry provision etc. as required and comprising of following: 2.1 One No. of 125 A, 36 KA, 4P MCCBs with Microprocessor Based Releases for OC/SC/EF Protection as INCOMER with CT Operated MFM of Conserve Make Model EM6400 or Equivalent, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. 2.2 Four No. of 40 A, 25 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps as required. 2.3 Four Nos. 32 A, DP "C" curve, 10KA MCB for single phase supply as required. 2.4 One Set of 200 Amps Al. Bus Bars with at Par Neutral BUS BARS as required. ALL AS ABOVE 2.1 To 2.4
Supply of following sizes XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade conforming to IS:7098 (Part 1) with upto date amendment etc. complete as required.
3.5 core x 95 Sqmm.
3.5 core x 70 Sqmm.
3.5 core x 35 Sqmm.
4 core x 25 Sqmm.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
Providing and Fixing of 100 mm dia (medium class) G. I. pipes i/c digging work of 0.5 meter depth & 0.3 meter width for the road crossing & filling the surface with 1:3:6 PCC of 1 feet width and 4 inches deep complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 25 sq. mm (28mm)
3.5 X 95 sq. mm (45mm)
3.5 X 70 sq. mm (38mm)
3.5 X 35 sq. mm (32mm)
3 X 10 sq. mm (22mm)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
SITC of Single Phase, 240 V, 50 Hz Electronic Energy Sub-Meter with LCD display and Box of range (5-30) Amp. at different locations.
BR Power Control and Automation Services
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .