Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-Not Submitted EMD |
Tender Value
₹49.3 L
EMD Value
₹49,250
Closing Date
12 Jan 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(PT-I), IMC, Itanagar
Itanagar
Const. of Breast wall at Lobi colony, 2. Const. of RCC drainage System at Senki park near MLA Bunglow Tinali to Senki river ward no.8
2023_IMCAP_999_1
IMC/EE(PT-I)/17/2022-23
Open Tender
Civil Works
Item Rate
183 days
Itanagar
Tender Fee, EMD and Documents as per NIT
4 documents required · 4 mandatory
₹5,000
EE(PT-I), IMC
₹49,250
12 Jan 2023
4 Jan 2023
12 Jan 2023
4 Jan 2023
12 Jan 2023
4 Jan 2023
Amount
SH:- C/o Breast wall at Lobi Colony
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)
Ordinary rock (not requiring blasting)
A) Manual Means (i) Depth upto 3 m
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.
RCC Grade M20/ Using Concrete Mixer
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification
RCC Grade M20/ Using Concrete Mixer
Reinforcement of RCC work including bending, binding and placing in position complete. In Footing and Main Wall b) Tar/TMT steel
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation,footing,base of column etc.and mass concrete.
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Back filling behind wall complete as per drawing and Technical specification
Providing weep holes in Reinforced concrete in wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
Add for Carriage of Materials ( As per Annexure-A )
SH:- C/o RCC Drainage System at Senki Park near MLA Bunglow Tinali to Senki River ward no.8
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)
Ordinary rock (not requiring blasting)
A) Manual Means (i) Depth upto 3 m
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.
RCC Grade M20/ Using Concrete Mixer
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification
RCC Grade M20/ Using Concrete Mixer
Reinforcement of RCC work including bending, binding and placing in position complete. In Footing and Main Wall b) Tar/TMT steel
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation,footing,base of column etc.and mass concrete.
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Back filling behind wall complete as per drawing and Technical specification
Providing weep holes in Reinforced concrete in wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
Add for Carriage of Materials ( As per Annexure-A )
M/S RUHI TACHU ENTERPRISES
stage.html
html • 0.02 MB
finance_1109.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .