Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.2 L+₹43,702 (1.19%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.8 L+₹1.1 L (2.94%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.6 L+₹2.9 L (7.92%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.9 L+₹3.2 L (8.67%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
9 Oct 2023, 6:00 pmClosed
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
PROVN OF UNDER GROUND ELECTRIC CABLES IN PLACE OF OVERHED ELECTRIC LINES ,ELECTRIC GEYSER, ELECTRIC CHIMNEY AND SPLIT AC AT CHHEOKI MH NEW CANTT UNDER GE WEST PRAYAGRAJ
2023_MES_614449_2
8681/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹91,000
Yes
14 Dec 2023
20 Sept 2023
10 Oct 2023
20 Sept 2023
9 Oct 2023
26 Sept 2023
Amount
Dismantling/Taking down existing ACSR aluminium conductor any size complete all as specified and directed.Note-Dismantalled ACSR conductor shall be deposit in E/M Yard.
Dismantling/Taking down unsv/broken/rusted MS Clamp,support,cross arm, GI washer,nuts of any size and shape including GI wire etc complete all as specified and directed.
Dismantling /taking of existing insulator of any size any type including MS spindle etc complete all as specified and directed
Excavation in trenches n.exceeding 1.50m wide and n.exc 1.50m depth for foundation etc or for laying of cable etc n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified & directed.
Returning, filling in including spreading, levelling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified & directed. Note:- Punned thickness shall be measured for payment.
M&L for 50 mm bore GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified & directed.
M&L for 80 mm bore GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified & directed.
M&L for 100 mm bore GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified & directed.
Supplying, laying commissioning and testing of LT underground cable of size 185 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 120 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 95 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 70 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 50 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 35 Sq mm 3.5 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
Supplying, laying commissioning and testing of LT underground cable of size 10 Sq mm 4.0 core 1100 volt grade, XLPE insulated , PVC sheathed heavy duty armoured with multistranded aluminium conductor are as per IS :7098 (Part -1) 1998, laid in trenches , duct , pipes or on poles etc. including cable gland, cable lugs, jointing, supporting clamps etc of the under mentioned type and sizes complete all as specified and directed.
S&F 2.5 sqmm 3 core flexible copper cable from junction box to street light complete all as specified and directed.
S&F PVC junction box of size 200x150x100 mm including two no. aluminium bus bar of 2mm thick dully fitted on the suitable insulators with fixing with 35x6 mm MS flat iron clamp with nut bolt and washers and incl.one MCB SP 6 amp.with rail fitted in PVC box including suitable size cable hole, and gland complete all as specified and directed.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 400 Amp 36 KA Amps -1 No. (Thermal and magnetic adjustable type) OUTGOING (b)MCCB 200 amp 25 KA -1 No , (c) MCCB 250 amp 36KA-2 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 400 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 125 amp 25 KA -02 No , (c) MCCB 250 amp 36KA- 02 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 200 Amp 36 KA Amps -1 No. (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Grouting of panel including earth work as required in PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 400 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 125 amp 25 KA -1 No , (c) MCCB 250 amp 25KA-02 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 160 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 100 amp 25 KA -02 No , (c) Phase indication lamp, LED type(set of 3) -1 Set (d) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 320 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 250 amp 25 KA -4 No , (c) MCCB 125 amp 25KA-1 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 250 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 160 amp 36 KA -2 No , (c) MCCB 100 amp 25KA-1 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 250 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 250 amp 25 KA -1 No , (c) MCCB 100 amp 25KA-01 No (d) Phase indication lamp, LED type(set of 3) -1 Set (e) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
Supply, fixing , connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, with suitable size and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 600 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve, provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- INCOMER-(a) MCCB 160 Amp 36 KA Amps -1 No. OUTGOING (b)MCCB 125 amp 25 KA -02 No , (c) Phase indication lamp, LED type(set of 3) -1 Set (d) Ammeter analog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each Phase (f) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (g) Grouting of panel including earth work as required PCC 1:3:6 type C-1 using 20 mm gradated stone aggregate & plastering with CM 1:4 complete.
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. and connected to the earth point and testing complete all as specified and directed.
Supply, Installation, commissioning & testing of electric chimney of size 180 cm X 120cm of stainless steel, baffle filter capacity 1000-1200 (cum/h), Noise level 80 DB, shape rectangular Duct size 6 feet (maximum) , voltage 240V wall mount panel and including all fitting accessories etc complete all as specified and directed.
M&L for concealed submain wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 10.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm as earth continuity conductor for 8 way DB complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB SPN 40/63 Amps 'C' series, breaking capacity 10 KA of rating & making connection complete all as specified and directed.
Supply, installation, commissioning and testing of 5 star rated split air condition of capacity 1.5 TR (4500 Kcal/Hr) complete with cordless remote control unit and air ionizer and plasma filter for better air quality. Indoor unit shall be Hi wall mounted type suitable for 230 volts, 50 Hz, single phase AC supply and capable of performing the function as cooling, air circulating and filtering. The air condition shall be complete with automatic temperature control ( by comprising of variable speed / variable tonnage depending upon heat load inside the room) with electronic thermostat complete as per IS 11338 of 1985. Outdoor unit of the AC shall be fitted with discharge cooled type rotary / scroll compressors operating on non CFC refrigerant with suitably rated capacitors start electric motor equipped with overload protection and duly mounted on resilient mounting for quite operation. The casing of indoor unit shall be made of ABS/HIPS/GS. The control box of the indoor unit shall with stand flame retardant test to grade V/O as per UL 94. The filter packs provided shall be washable. Remote cordless control with LCD/LED display shall be provided on indoor unit and on handset. Overall powder factor of the unit shall not be less than 0.85 at operating conditions. The inverter type AC shall correlate to the values as specified by the OEM and latest IS/BIS certification as mentioned in the table 2.2 of the Gazette of India notification No. 024 (E) dated 5 Jan 2010 issued by central Government of India.
S & F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170v to 250v with out put voltage stabilizer at 230v with accuracy of + 2.5% and of capacity 5 KVA complete all as specified & directed.
S&F vertical /horizontal water heater storage type, electrically operated of capacity 25 litres, BEE 5 star rated ABS/ steel body and inner tank made with stainless steel duly thermal insulated with 2 KW heating element complete with and including vent pipe , fusible plug, safety valve, earth connector, PVC connections(hot and cold) and electric connection all as specified and directed. Make:- Havells (Cat Part No GHWAMGTWH025 , Crompton (Cat Part No.Matteo 25) , Bajaj (Cat part No. MAJ 25GL (New) as approved by GE.
M&L for concealed submain wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm as earth continuity conductor including taking down complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, B series 240 volts AC complete all as specified & directed.
S&F stop valve, cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe or for unions for 15 mm bore and fixed complete all as specified & directed.
S&F PVC connection cotton braided heavy duty with brass union / coupling of length 450 mm with rubber & washers suitable for 15 mm bore pipe complete all as specified & directed.
S&F Bib taps of 15 mm bore, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, iron pipe or for screwed for brass ferrule and fixed complete all as specified & directed.
S&F switch piano, flush type 16 amps, single pole, one way 230 volt complete all as specified & directed.
Hi-Tech Constructions
M/s RAM LAKHAN GUPTA
Avion Industries
Ambrish Builders
P S TRADERS
Ajanta Associates
Titco Electricals
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .