Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹40.5 L+₹2.7 L (7.16%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | L2 | Rejected-Finance 2nd lowest bid |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
20 Jun 2022, 6:00 pmClosed
GE SAUGOR
GE SAUGOR
COMPREHENSIVE MAINT AND REPAIR OF DIESEL GENERATING SET OF VARIOUS CAPACITY INSTALLED AT DIFFERENT LOCATIONS ALONGWITH CRANES, CONNECTED ITEMS OF WATER FILTRATION PLANT AND ALLIED WORKS AND REPAIR AND MAINTENANCE OF OLD RCC,GI,CI,DI PIPE LINE OF VARI
2022_MES_526056_1
GE/SGR/TOK-24 OF 2022-23
Open Tender
Civil Works - Water Works
Item Rate
180 days
SAUGOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAUGOR
₹78,000
Yes
18 Jul 2022
27 May 2022
22 Jun 2022
27 May 2022
20 Jun 2022
8 Jun 2022
Amount
Periodical maintenance of DG set of 320 KVA Capacity as per manufacturer recommendations, installed at various location and various capacity complete all as specified and directed. Note:- (a) Checking the fanbelt , Fuel , Oil filter, Air Filter, FIP Performance,FIP Oillevel, Tappet Clearance, adjustment of fuel pump timing, tighting of base bolt nuts, battery distilled water level, vibration damper mounting, radiator, radiator hose, panel board cable connection tighting (b) Highly skilled labours and tools for maintenance/checks repairs/replacement is deemed to be included in the rate quoated by the contractor (c) Replacement of spares , Coolant,Distilled water , Engine Oil, Fuel/Oil/Air filtershallbe measured under relevant items & Minor spares parts which rate below Rs. 200 include in this item of nature (d) Mechanic, Supervisor and Maintenance Engineer must be skilled and must have knowledge of maintenance of DG Sets and attending minor and Major fault when it arise
All as per Srl item No.1 above but DG set of 180 KVA Capacity
All as per Srl item No.1 above but DG set of 125 KVA Capacity
All as per Srl item No.1 above but DG set of 90 KVA Capacity
All as per Srl item No.1 above but DG set of 63/62.5/60 KVA Capacity
All as per Srl item No.1 above but DG set of 40/30/20KVA Capacity
All as per Srl item No.1 above but DG set of 12.5/7.5 KVA Capacity
Disconnecting, removing and dismantling radiator assembly of 7.5/12.5/20/30 KVA Capacity Genset capacity DG sets and descaling the radiator throughly with CTC solution/any other chemical solvent agent as approved by the Engineer-in-Charge, stopping of leakeage at place to copper cores and tubes by brazing scapping the existing Oil paint, dusting and painting the radiator with enamelled paint etc re-installing and commissioning all as directed
All s per Srl item No.8 above but 40/62.5/90 KVA Capacity Genset
All s per Srl item No.8 above but 125 KVA Capacity Genset
All s per Srl item No.8 above but 180 KVA Capacity Genset
Disconnecting the existing battery of capacity 12V, 92/100 AH from the DG Set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, start the engine for satisfactory function all as directed by Engineer-in-Charge.
All s per Srl item No.12 above but but 12V,180AH
M&L for replacing the worn out carbon brushes slipring type in alternator of 7.5/20/30 KVA capacity DG set including all necessary connected works all as directed by Engineer-in-Charge.
All s per Srl item No.14 above but 60 to 90 KVA Capacity Genset
M&L for cleaning complete genset and panel surface, scraping down the old faded existing paint from the 7.5/12.5/30 KVA Capacity Genset of making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coats of synthetic enamel paint over one coat of red oxide primer, painting over the panel including written of the details of panel,Engine & Alternator SM,MES No and date of installed and capacity all as specified and directed by Engineer -in-Charge.
All as per Srl item No.16 above but 40/62.5/90/125 KVA Capacity Genset
M&L for cleaning complete inside of wall surfaces (4 sides) of Berthuma filteration plant ( Filter No. 1&2), Scraping down the old faded paint from the inside walls of filteration plant of making surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coat of colour oil paint over the one coat of white oil paint including written of the details of filter plant capacity, Date of cleaning complete all as specified and direted by Engineer-in-Charge
Draining out the existing diesel from the tank from the 7.5/12.5/20/30 KVA Capacity Genset , kept as side for repouring, taking down the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carryout cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recaliberation of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and test for satisfactory function all as directed by Engineer-in-Charge.
All as per Srl item No.19 above but 40/62.5/90 KVA Capacity Genset
All as per Srl item No.19 above but 125/180KVA Capacity Genset
All as per Srl item No.19 above but 320 Capacity Genset
M&L for removing and replacing defective AVR from Alternator upto 90 KVA DG sets complete all as specified directed. Note:- Make of the item replaced should be as per the exisitng make.
All as per Srl item No.23 above but Alternator capacity 125 to 180 KVA Capacity,
All as per Srl item No.23 above but Alternator capacity 320 KVA Capacity,
Servicing to DG Set Control Panels Cleaning with blower, Cleaning with CTC ,Replacement of damaged lugs , Replacement of deteriorated copper wiring ,check the power contactors , Rectifying of loose connections , removing contactors and cleaning the points, refixing it in its original position complete all as specified and directed by Engineer-in-Charge. Note:- Spare parts shall be measured and paid under under relevant items as "Supply only"
Supply only following items complete all as directed:-
ON/Off Push button
Oil temperature gauge alongwith all connected items as per existing sample
Water temperature gauge alongwith connected items as per sample
Volt Meter as per existing size with connected items as per sample
Ammeter as per existing size with connected items as per sample
DC Volt meter as per existing size with connected items as per sample
DC Ammeter as per existing size with connected items as per sample
Frequency meter as per existing size with connected items as per sample
RPM Meter along with cable as per existing sample
LED indicator lamps as per existing sample
Fuse alongwithback light fuse carries as per existing sample
Oil Flexible Hose as per sample
Diesel Flexible hose as per sample
Ignition key alongwith bush button starter
M&L for replacing the old unserviceable battery lead with copper terminals approximately 2.5 mtr length including applying jelly over the battery pole and terminals all as directed by Engineer-in-Charge.
M&L for replacing the old unserviceable battery Terminals ( Positive& Nagative ) including brazing work and applying jelly over the battery pole and terminals all as directed by Engineer-in-Charge.
M&L for replacing the damaged/burn out battery terminal pole (positive/nageative) 12 V DC battery and recosting lead as per the site requirement complete all as specified and directed by the Engineer-in-Charge
S&F in replacement of the following spares complete all as directed:-
Oil filter capacity 1/2 litre with 'O' ring
Oil filter capacity 1 litre with 'O' ring
Diesel filter capacity 1/2 litre with'O' ring ( Pre & Micro)
Diesel filter capacity 1 litre with 'O' ring ( Pre & Micro)
Sump/Crank case packing suitable for 7.5/20/30 KVA Capacity Genset
Sump/Crank case packing suitable for 40/62.5/90 KVA Capacity Genset
Sump/Crank case packing suitable for 125/180KVA Capacity Genset
Sump/Crank case packing suitable for 320 Capacity Genset
Air filter suitable for 7.5/12.5/20/30 KVA Capacity Genset
Air filter suitable for 40/62.5/90 KVA Capacity Genset
Air filter suitable for 125/180KVA Capacity Genset
Air filter suitable for 320 Capacity Genset
Rocker arm packing kit suitable for 7.5/20/30 KVA Capacity Genset
Rocker arm packing kit for 40/62.5/90 KVA Capacity Genset
Rocker arm packing kit 125/180KVA Capacity Genset
Rocker arm packing kit 320 Capacity Genset
Engine Oill 20W-40 Make : Castrol/BP
Oil filter suitable for Kirloskar cummins engines upto 320 KVA Capacity Genset as per the existing sample
Fuel filter suitable for kirloskar cummins engines upto 320 KVA Capacity Genset as per the existing sample
Distilled water
Broom made by Cocount trees branches along with bamboo stick as per sample
Cotton Waste
Breather flow pipe as per sample
M&L for replacing the existing damaged/bulged radiator flexible rubber hose of the 7.5/12.5/20/30 KVA Capacity Genset installed at various installation and replaced with new radiator flexible hose with circular hose clips complete all as specified and directed by the Engineer-in-Charge
All as per Srl item No.32 above but 40/62.5/90 KVA Capacity Genset
All as per Srl item No.32 above but 125/180KVA Capacity Genset
Taking down the existing worn out Fanbelt (V Belt) from the 7.5/12.5/20/30 KVA Capacity Genset installed at various installation and replaced with new fan belt complete all as specified and directed by the Engineer-in-Charge
All as per Srl item No.35 above but 40/62.5/90 KVA Capacity Genset
All as per Srl item No.35 above but 125/180KVA Capacity Genset
All as per Srl item No.35 above but 320 Capacity Genset
Taking down the existing defective radiator cap from the Radiator and replaced new radiator cap complete all as specified and directed by the Engineer-in-Charge
Taking down the existing unserviceable DG Set control panel from DG set installed at GE MT yard 60 KVA Capacity supply and fixing new DG Set control panel Made by MS sheet 2mm thick with pedestal fitting with DG set frame , consisiting of Volt meter,Ammeter, RPM Meter with connected cable ,Battery charging cut out regulator, Ignition switch, ON/Off bush button, Oil temperature gauge, Water temperatur gauge, Oil pressure gauge including internal wiring , testing commissioning complete all as per specified and directed by Engineer-in-Charge
All as per Srl item No.40 above but 30 KVA Capacity installed at Pump House No. 24
S&F Battery12 V 180 AH for DG set complete all as specified and directed by Engr-in-Charge.
Taking down the top layer of the existing filter media for Rapid Sand filtration plant No. 1 & 2 at berthuma filtration plant and Swimming pool water filter plant (Location : Hawk Hill & MRC) removal to a distance not exceeding 50 metre and dopositing where directed all as specified and directed.
Refilling the serviceable media (ie pebbles) of various sizes obtained from taking out vide item No.40 in the Rapid sand filtration plant after cleaning with acid and pure water etc complete all as specified and directed.
Supply and fill Quartz sand 16x 30 Mesh as filter media in the RAPID sand filtration plant plant complete all as specified and directed. Note: Grading and size of sand shall be tested in the approved laboratory and test results shall be submitted and the rate quoated shall be deemed to include the above provision
Supply and fill Brown sand 8x12 Mesh as filter media in the RAPID sand filtration plant plant complete all as specified and directed. Note: Grading and size of sand shall be tested in the approved laboratory and test results shall be submitted and the rate quoated shall be deemed to include the above provision
Supply and fill Brown sand 4x8 Mesh as filter media in the RAPID sand filtration plant plant complete all as specified and directed. Note: Grading and size of sand shall be tested in the approved laboratory and test results shall be submitted and the rate quoated shall be deemed to include the above provision
M & L for cleaning the Clarifier located at Berthuma Filtration plant by de-watering/Drainout the Clarifier , removing the silt/sludge deposited at bottom, walls complete, cleaning the sump internally using high pressure water jets complete all as specified and as directed by Engineer in Charge
M & L for cleaning the Fluculator located at Berthuma Filtration plant by de-watering/Drainout the Fluculator , removing the silt/sludge deposited at bottom, walls complete, cleaning the sump internally using high pressure water jets complete all as specified and as directed
Supply only Belt of size B-95/92/94 for Fluculator complete all as directed
Supply only Compressor Oil for Fluculator complete all as directed
Supply only Belt for Air Compressor for Fluculator complete all as directed
M&L for cleaning complete Clarifier and fluculator MS plate foot path surface and side pipe railing, Scraping down the old faded existing paint and making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coats of synthetic enamel paint over one coat of red oxide primer, painting over the area including welding as required complete all as specified and directed by Engineer -in-Charge.
Comprehensive Maintenace with Material and servicing, Oiling overhauling the fixtures accessories replacement of first moving parts changing as per manufacturer recommendation of Oil fired double chamber incineator of capacity 20Kg/hr with diesel Oil pump mounted installed at MH Saugor complete all as specified and directed by Engineer-in-Charge Make : Halt Incineator Note:-(i) To check the allignment of all machinaries and accordingly correct the same.(ii).Oiling and greasing of each machine by mechanical method like a pressure pump etc . (iii). The rate for the minor parts required for repair the parts is to be included
Material and labour for disconnecting electrical and mechanical connections of the 7.5/20/30 KVA Capacity Genset Altrernatror , 415V, 50 HZ removing from foundation/diesel engine coupling and Transporting private Work shop, dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and winding F class copper conductor winding wire of exsisting size/shape , glass sleeves of connecting leads, binding/tightining loose coils with binding cloths , varnishing and applying the bactol on the excitor coil/winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning ,greasing, reassembling/installing/connecting and testing with megger for insualtion resistance etc as directed by the Engineer-in-Charge
All as per Srl item No.55 above but 40/62.5/90 KVA Capacity Genset
All as per Srl item No.55 above but 125 Capacity Genset
Taking down the existing defective injector and fuel injection pump (FIP) for the 7.5/20/30 KVA Capacity Genset installed at various installation and replacement of work out spares like delivery valves, Nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP and refixing in same position and testing of full load checking of pressure complete all as specified and directed by the Engineer-in-Charge
All as per Srl item No.58 above but 40/62.5/90 KVA Capacity Genset
All as per Srl item No.58 above but 125/180KVA Capacity Genset
All as per Srl item No.58 above but 320 Capacity Genset
Taking down the existing defectiveSelf starter from Genset 12 V Capacity installed at various installation and replacement of work out spares like Bendex drive, carbon brush , solinoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engineer-in-Charge
All as per Srl item No.62 above but 24V
M&L for cleaning complete swimming pool Filter plant and MS pipe line, sluice valve , control panel, pump set, suction sweeper motor, Scraping down the old faded existing paint from Hawk Hill & MRC filter media cylinder connected pipe lines and CI sluice valves of making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, incuding welding and packing the water leakege portion ,applying two coats of synthetic enamel paint over one coat of red oxide primer, painting over the panel and two coats bituminous paint insideof filter media cylinder including written of the details of water flow direction and capacity of the plant, and date of installed and capacity all as specified and directed by Engineer -in-Charge.
Taking down the existing defective Alternator/Dynamo from Genset 12 V Capacity installed at various installation and replacement of work out spares like armature, carbon brush,diode, wiring the alternator and dynamo refixing in same position and testing complete all as specified and directed by the Engineer-in-Charge
All as per Srl item No.65 above but 24V
Material and labour for repairs/servicing of Sathya sai dozing system plunger type injection soultion 25 LPH coupled with three phase motor 0.5 HP Capacity motor ,1440 RPM, including replacement of unserviceable spares and recommissing and testing after repair complete all a specified. Make:- Sathya Sai Aqua Pura Services , Pune
M&L for disconnecting the electrical connection from terminal box from motor, 3Ph, 415V,0.5 HP Capacity removing from top of chemical drum , dismantling the motor and removing burnt out winding from slots carefully, cleaning the slots and replacing the insulating paper and copper winding wire of existing gauge, connecting the laeds, varnishing and applying the actol on the coil with varnish, heating the winding including replacement of NDE/DE bearings, re assembling, installing, testing commissioning complete all as specified and directed.
Supply only following items suitable for dozing pump complete all as directed:-
Gun metal Non return valve 15 mm dia
UPVC pipe 15 mm dia
Diaphragm as per sample
Oil Suitable for dozing gear box
Mixture pipe
Rubber packing as per sample
Foot valve as per sample
DOL Starter suitable for 0.5 HP Capacity 3Ph, 415V consisting of SPP as per sample Make: L&T, Havells,C&S,CG
Material and labour for repair/servicing of Aqua fit dozing system high pressure single head adjustable 5Kg/cm2 max out put dozing pumps electrically operated single phase 220V 50Hz, 960 RPM, 120W including replacement of unservieable spares and recommissiong and testing after repair complete all a specified and directed. Make: Aqua Fit Note:- Spares requird for servicing shall be measured and paid seperately under relevent items mentioned here-in-after
Supply only following items of make suitable for existing chemical dozing pumps complete all as directed:-
Special flexible nylon suction tubing 15 mm dia to with standwater pressure minimum 10Kg/cm square
Suction valve Non-metallic
Injection/check valve non metallic
PCB for chemical dozing pump
Chemical level sensing automatic shout down switch
M&L for disconnecting the electrical connection from terminal box from motor, SP, 220V,120W capacity, 900 RPM, 415V, removing from top of chemical drum , dismantling the motor and removing burnt out winding from slots carefully, cleaning the slots and replacing the insulating paper and copper winding wire of existing gauge, connecting the laeds, varnishing and applying the actol on the coil with varnish, heating the winding including replacement of NDE/DE bearings, re assembling, installing, testing commissioning complete all as specified and directed.
Carry out Labortary analysis test of treated and unreated drinking water Bacteriogical examination of standard plate count, total oilform, Faecal Coliforms, Faecal Streptococcus and physical examination report to e submitted to department as received from laboratary. Note: The Labortary test shall be carried out at Madhya Pradesh water and drainage board.
M&L for excavation soil up to 5cm root of the vegetation cutting removing completely by spade and surface dressing all around the all DG Set installation area to keep the installation area(external only) clean and tidy all as per specified and directed by Engineer -in-Charge. NOTE: All the installation shall be kept clean through out the contract period by repeatedly removing the grasses/trees/weads as many times as required depending on the growth of the grass.This item shall be measured and paid only separately
S&F Synthetic insulating mat of size 2mx1x10mm thick in DG set insallation with necessary fixing accessories and arrangement complete all as directed
M&L for E/M installation Machinery details sign board single side Acrylic sign board made by strong adhesive back finish support with stickering letters of and fixed with metallic screw with washer,board size, letter size as per site requirement direction given by Engineer-in-Charge. Note:- Marking of the letters/Machinery data as per the directions given by Engineer-in-Charge
Excavation in trenches in Hard/dense soil not exc 1.5m wide & not exc 1.5 deep and getting out for laying of pipe complete all as specified and directed..
Removing excavated material not exc 50 m and depositing where directed of a level not exc 1.5m above the starting point complete all as specified and directed.
Returning filling trenches with excavated earth including spreading leveling watering and well ramming in layer not exc 25 cm complete all as specified and directed.
Supply and laying GI tubing, medium grade galvanised with all fittings specials such as bend, elbows,tees, short pieces connection, back nuts, diminishig pieces, caps, plugs and unions laid in trenches of following size including taking up or down of old GI tubing and connections for the following sizes, including removal complete all as specified and directed by Engr-in-Charge (Note: Excavation and earth work shall be measured and paid separately):-
15mm dia of pipe
20mm dia of pipe
25mm dia of pipe
40mm dia of pipe
50mm dia of pipe
80mm dia of pipe
100 mm dia of pipe
Supply and lay tubing,medium grade galvanised with all fittings such as bend, elbows,tees, short pieces connection, back nuts, diminishig pieces, caps, plugs and unions etc laid in walls, ceiling & laid in floor with and including suitable clamp with wooden plug alongwith screws in intervals of following sizes including taking up or down of old GI tubing and connections for the following sizes, including removal complete all as specified and directed by Engr-in-Charge:-
15mm dia of pipe
20mm dia of pipe
25mm dia of pipe
40mm dia of pipe
50mm dia of pipe
80mm dia of pipe
S&F in replacement Gun metal globe valve with iron wheel of following size, screwed both ends for iron pipes complete all as specified and directed:-
15mm dia
20mm dia
25 mm dia
40 mm dia
50 mm dia
Opening the top of the sluice valve carefully, taking out the gate & spindle, scraping/cleaning the gate both sides, cleaning/ scraping of sluice valve body throughly from inside, refixing / replacing the spindle, gate cheak nut and top of sluice valve including replacement of gland packing rope of suitable size & rubber gasket and Bolt,nut with washers necessary metalling ,grinding and levelling of the valve door seating complete for the following sizes of Sluice valve (Note:-Replacement of check nut/ spindle etc shall be measured and paid separately as "Supply only" under relevant items) :-
80 mm dia.
100 mm dia.
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
Supply only spindle stainless steel suitable for following size CI sluice valve :-
80 mm dia.
100 mm dia.
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
Supply only sluice valve check nut Gun metal as per sample (Square/rectangle) of following size :-
80 mm dia.
100 mm dia.
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
M&L for the spigot and socketed CI pipe run lead joint complete for repairs to leakage/repairs by using JCB/Poklane arrange sufficient manpower to arrest leakage/brakedown continue shift wise all as specified and directed by Engineer-in-charge (Note : Earth Wrok/PCC & CI/DI Specials shall be measured and paid separately under respective items:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for cast iron bends (any radius and angle) tappers any type (Straight, bend, increasing, decreasing or double socket) Tee, pieces single branch, “ Y” junction, double branch, cross ( all socket or socket spigot) collars, caps, caps & plugs upto the 150mm dia complete all as specified and directed
Cast iron bends (any radius and angle) tappers any type (Straight, bend, increasing, decreasing or double socket) Tee, pieces single branch, “ Y” junction, double branch, cross ( all socket or socket spigot) collars, caps, caps & plugs of the size of 200 to 300mm dia complete all as specified and directed
M&L for run lead joint for spigot and socket pipes and fittings of the following sizes including Ttking out the unserviceable lead joints including spun yarn :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
S&F in replacement double action flanged Air release valve of size 80 mm dia including taking down the existing unserviceable ARV from the existing pipe line including replacement of bolt, nuts with washers and gasket complete all as specified and directed by Engr-in-Charge.
M&L for cutting of bituminous Road/floor/plinth protection for laying pipe not exceeding 1.5mm and 1.5 depth including refiling with excavated material and watering well ramming/compecting and making good with PCC 100 mm thick complete all as specified and directred by Engg-in-charge Note: PCC shall be measured separately
M&L for PCC 1:4:8, type B1 (using 20 mm graded stone aggregates) as in filling and making good distrubed surface complete all as specified and directed
S&F in replacement including leak proof of GI tubing fittings ,ISI marked fixed in trenches/floors etc complete all as specified and directed by Engr-in-Charge of the following sizes ( Note:- Excavation and earth work shall be measured and paid seperately):-
GI Socket 15 mm dia
GI Union 15 mm dia
GI Elbow 15 mm dia
GI Socket 20 mm dia
GI Union 20 mm dia
GI Elbow 20 mm dia
GI Pipe Nipple 15 mm dia 3" long
GI Pipe Nipple 15 mm dia 6" long
GI Pipe Nipple 20 mm dia 3" long
GI Pipe Nipple 20 mm dia 6" long
GI Socket reducer 20x15 mm
GI Socket reducer 25x15 mm
GI Socket reducer 25x20 mm
Shellac Bottle 50 ML
Pig lead
PVC Wiper alongwith stick as per sample
Nylon mesh alongwith MS rod 5mm thick not less than 2.2 metre as per sample and as per site requirement
Cotton thread
Carry out day to day rectification of water supply complaints at Area I & Area II like Leakege of water supply line any sizes, brocken/Crack of the GI/CI/DI Pipes any sizes, replacement of unserviceable Gate valves, replacement of gland rope and rubber packing to any size of Sluice valves etc complete all as directed Note: (i) . Replacement of GI Fittings shall be measured and paid separately. (ii). GI Pipe shall be mesured and paid separately. (iii). If required excavation and earth work will be measured and paid separately. (iv). Materials like Lead,Gate valves, gland rope,rubber packing, Shealloc bottole,cotton thread etc shall be measured and paid separetely (v). Pipe fitter with Helpers so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (vi). Rate included with transport vehicle provided by the contractor to attending the complaints Area I .(vii). Attending the complaints not less than min four complaints per day
S&F mild steel clamp less than 5 mm thick split type and necessary drilling/welding GI socket as per site requirement alngwith two nos of GI Bolt,nut with washer suitable for CI/DI 80 mm dia water pipe line complete all as specified and directed.
All as per Srl item No.95 above but 100 mm dia
All as per Srl item No.95 above but 150 mm dia
All as per Srl item No.95 above but 200m dia
All as per Srl item No.95 above but 250 mm dia
All as per Srl item No.95 above but 300 mm dia
S&F in repairs bip tap 15mm bore standard of PTMT any colour screwed for iron pipe & fixed (min. weight 15mm - 90gms) complete all as specified and directed.
M&L for construction of brick masonary valve pit chamber including necessory earth work, PCC, coping, plastering on internal surface of valve pit, framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3 mm thick confirming to Fe 410-0 and Fe 310-0 including welding cutting hinjes locking arrangement complete and two coats of synthetic enamel paint over a coat red oxide primer applied on the valve pit cover complete all as specified and directed:-
900mmx900mmx600 mm
1200mmx1200mmx1000 mm
1500mmx1500mmx1000mm
SHRI RAM ELECTRICALS ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .