Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC | ₹7.1 Cr | L1 | Accepted-AOC L1 being lowest |
| 2 | L2₹9.1 Cr+₹2.0 Cr (27.8%)Rejected-Finance | ₹9.1 Cr+₹2.0 Cr (27.8%) | L2 | Rejected-Finance other than lowest |
| 3 | L3₹9.2 Cr+₹2.1 Cr (30.2%)Rejected-Finance EAST LANE GALI NO 01 ABROL NAGAR PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹9.2 Cr+₹2.1 Cr (30.2%) | L3 | Rejected-Finance other than lowest |
| 4 | L4₹9.5 Cr+₹2.3 Cr (33.0%)Rejected-Finance | ₹9.5 Cr+₹2.3 Cr (33.0%) | L4 | Rejected-Finance other than lowest |
| 5 | L5₹9.7 Cr+₹2.6 Cr (36.2%)Rejected-Finance 2ND FLOOR 15 BHULLAR AVENUE ADJOINING SBI FATEHGARH CHURIAN ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹9.7 Cr+₹2.6 Cr (36.2%) | L5 | Rejected-Finance other than lowest |
Tender Value
₹9 Cr
EMD Value
₹7.8 L
Closing Date
30 Mar 2023, 6:00 pmClosed
Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone
ADDITION ALTERATION INCLUDING REPAIR TO ORS JCOS AND OFFICERS MD ACCN AT MIL STN PATHANKOT UNDER GE (WEST) PATHANKOT
2023_MES_580494_2
CEPZ-30/2022-23
Open Tender
Civil Works
Item Rate
550 days
GE(West) Pathankot
All as per tender documents
7 documents required · 7 mandatory
₹3,000
Yes
GE (WEST) PATHANKOT
₹7.8 L
Yes
22 Jun 2023
15 Mar 2023
6 Apr 2023
15 Mar 2023
30 Mar 2023
23 Mar 2023
Amount
BUILDING WORKS: Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast RCC articles and disposal of debris out of MoD land complete all as specified and directed.
Material & Labour for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
All as per item No 02 above but except bricks. (NOTE: Old burnt clay bricks retrieved from demolition shall be used.)
Material & Labour for brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
All as per item No 04 above but except bricks. NOTE: Old burnt clay bricks retrieved from demolition shall be used.
Demolition of cement concrete or lime concrete (unreinforced) in ground floors and pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed .
Surface dressing n exc 15 cm deep in soft/loose of soil complete all as specified and directed by Engr-in-Charge.
Material & Labour for hard core of broken stones or boulders of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
Material and labour for PCC in foundations, filling and mass-concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed.
Material & Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints at every 2.5m and corner filled with bitumen 85/25 complete all as specified.
Material & Labour for 25mm thick in sub base for receiving floor tiles PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete all as specified and directed. (Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc)
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, soft/loose soil complete all as specified and as directed by Engr-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F mild roof structural steel angles/rectangular hollow section/steel tubular roof trusses (framed) purlins and fastening including distance pieces etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing the debris outside from defence land complete all as specified and directed .
Material & Labour for PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in padding on roof, surface finished even and smooth without using extra cement all as specified and as directed.(Note:- WPC shall be measured and paid separately)
Material & Labour for PCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in roof kerbs,bands etc or mud stops, rounded or chamfered on edges cement all as specified and as directed.(Note:- WPC shall be measured and paid separately)
Material & Labour for PCC 1:3:6 type C-1 ,M-10 (Nominal mix) using 20mm graded crushed stone aggregate as in filling of sunken floor to receive floor top finished complete all as specified and directed.
Material & Labour for 15mm thick rendering in CM (1:4) mixed with water proofing compound conforming to IS 2645 for as per manufacturer’s instructions. The surfaces then shall be cured and allowed to dry. All the joints of pipe be sealed properly, applying a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane Based Liquid Membrane on floor as well as on wall as per manufacturer’s. After the treatment, sunken portion shall be kept full of water for atleast one week to check seepage the work shall be got executed from the approved agency all as specified and as directed by Engr-in-Charge.
Material & Labourfor 50 mm bore ‘medium grade’ GI pipe with all fittings laid in trenches as in spout including neccesary cutting etc complete all as specified.
Demolition of existing roof treatment of any description such as worn-out tar felt, debris, mortar of any description & any thickness, surface cleaning of all foreign material such as fungus, moss, dust etc. by wire brushing and dusting including disposal of debris out of MoD land then surface levelled with a layer of 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and ensure water does not stand anywhere after Sprinkle water on the roof surface and Material & Labour for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specifications complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane.
Material & Labour for cutting out cracks to V-Section in existing roof or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 by weight complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roofs and disposal of debris out of MoD land complete all as specified and directed.
Material & Labour for 20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed. (Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded.)
Material and labour for coloured glazed ceramic tiles in vertical surface such as dado etc 450mmX 350mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed.
Supply and fix joint free non skid coloured Ceramic tiles 07mm to 08mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply and fix joint free non skid coloured ceramic tiles 07mm-08mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply and fix joint free non skid ceramic tiles, coloured 7mm to 8mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in vertical/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat/redering in cement mortar 1:4 for fixing of tiles complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& Brushing neat cement slurry with 3.0kg of cement per sqmetre complete all as specified and directed.
Supply and fix Vitrified Ceramic tiles 08 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply and fix Vitrified Ceramic tiles 08 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in vertical/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. (Note for item No(s) 25 to 28, 30 & 31:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary cutting in circular sharp nothing extra shall be admissible on this account).
Machine cut kota slab fooring 18 to 20mm thickness over cement screed base laid and jointed with gray cement slurry mixed with pigment to matches the shade of the slab including rubbing and polishing setting over 20mm thick screed bed or bedding layer of mortar in cm 1:6 for laying floor finishes, staircase and landing complete all as specified and directed by Engineer-in-Charge. (Note: The kota stone on tread/riser shall be fixed in single piece only)
Supply & fixing joint free glazed coloured ceramic tiles matching with kota stone colour 7 to 8mm thick (Square/rectangle) verticle/skirting surface etc. set & jointed in neat cement slurry and pointed in while or coloured cement to match, including 10 mm thick backing coat/rendering in cement mortar 1:4 for fixing of tiles completed as specified & as directed by Engr-in-Charge.
Demolition of RCC as in roofs, floors (other than ground floors), beams staircases, landing, cooking platform ,chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed. (Note:- Demolition will be done only with mechanical cutter)
Material and labour for RCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves complete all as specified and as directed. (Note:- Reinforcement shall be measured and paid separately).
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed
Material and labour for TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed.
Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed.
Material and labour for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.(Note:- WPC shall be measured and paid for separately)
Material and labour for two coats of plaster 15 mm thick (10 mm + 5 mm) on rough concrete surfaces of fin, facia, chajjas and similar article in cm 1:3 using liquid water proofing compound (as per manufacturer’s instructions) mixed in both coats, finished even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) (Note :- Two coat plaster shall be carried out as mentioned in clause 14.18 of SSR-2009, Part-I complete all as specified and directed.)
Material and labour for preparation of newly plastered external surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for complete removal of existing treatment from external surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for repairing of chajjas, roof projection and faces of exposed reinforcement surface or damaged loose RCC surface and applying one coat of cement slurry @3kg/Sqm and filling with cement concrete 1 : 2 :4 type B-0 (using 12.5 mm graded crushed stone aggregate ) mixed with liquid water proofing compound (as per manufacturer’s instructions) and finished with 05mm thick rendering with cement sand mortar 1 : 3 with liquid water proofing compound (as per manufacturer’s instructions) using coarse sand in patch and thickness of RCC member not exc 150 mm and reinforced with Welded steel wire fabric Supply and fixing of weight exc 2.00 Kg per sqm but not exc 4.00 Kg per sqm and finally applying two coats of exterior grade emulsion paint (weather proof/weather coat) without any brush marks on the surface in any colour over and including one coat of primer (as per manufacturer’s recommendations) including necessary scaffolding up to four storeys height of bldgs,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for rendering 10 mm thick in cm 1:6 on other than fair faces of brick work , concrete surfaces of wall,finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of newly plastered internal surfaces of wall and applying min 1.5 mm thick wall care putty on the surfaces & making the surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished smooth on the surface in any colour. Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of wall & making the surface smooth applying min 1.5mm thick wall care putty and two coats of distemper oil emulsion finished without any brush marks over a priming coat. Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for complete removal of existing treatment of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface smooth and applying two coats of distemper oil emulsion without any brush marks on the surface over a priming coat in any tint. Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for complete removal of existing treatment of wall and applying min 1.5mm thick wall care putty and two coats of distemper oil emulsion without any brush marks on the surface over a priming coat in any tint. Shade/colour shall be approved by GE,all painted areas site to be cleaned without any extra cost to Govt complete all as specified and as directed. (Note for item No 44 to 48: The work is to be executed upto four storey height. The contractor shall note this point before quoting rates.)
Material & Labour for rendering 5mm thick on fair faces of concrete surfaces in CM (1:3) on ceiling complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.
Material and labour for complete removal of existing treatment from ceiling surface and applying two coat of white wash on undecorated surfaces including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified & directed.
Material and labour for preparation of old painted steel and iron surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint in any colour finished surface including necessary scaffolding up to four storeys height of bldgs if required,Shade/colour shall be approved by GE, complete all as specified and as directed.
Material & Labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed.
Material and labour for writing letters or figures (block, Roman, Italic or Indian) exceeding 15 centimeter high but not exceeding 30 centimeter high etc with synthetic enamel paint including necessary scaffolding up to four storeys height of bldgs if required,Shade/colour shall be approved by GE, complete all as specified and as directed.
Material and labour for cutting down plants / trees of girth not exc 15 cm & surface are not exc 0.36 Sqm each from roof tops /sides of external walls of buildings, chajja, wall junctions, junctions of of rain water / soil /waste vent pipes including taking out roots making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (herbal medicine )and making good to suit the adjoining surfaces using PCC type 1:2:4, type Bo (using 12.5mm graded crushed stone aggregate) or cement mortar 1:2 complete all as per manufacturer instructions and as specified. (NOTE: Any CI/GI/PVC pipes and fittings damaged during work shall be replaced with new one to ensure leakage / seepage free joint without any extra cost to the department and Unit rate quoted by tenderer shall deemed to be included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs and removing of debris out of MoD land complete all as specified and as directed.)
Supply only `Liquid Water Proofing Compound. complete all as specified and as directed .
Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site.
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed.
Supply & Fixing pressed steel door frames 105 x 60mm, 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed by Engr-in-Charge.
Supply & Fixing pressed steel frames door 125 x 60mm, 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed by Engr-in-Charge.
Material & Labour for cement concrete 1:3:6 type C-0 using 12.5 mm graded crushed stone aggregate as in back filling of hollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed.
Supply and fixing 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999) , complete all as specified and directed by Engr-in-Charge.
Supply and fixing 35mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. (Note: wire cloth shall be measured and paid for separately)
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed by Engr-in-Charge.
Material & Labour for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Supply and fixing for solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet, reinforced with M.S square tube complete all as specified and directed Engr-in-Charge.
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet PVC ‘C’ channel having a plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading complete all as specified and directed by Engr-in-Charge.
Supply and fixed steel window/ventilator box type factory made, for double shutter i.e glazed and gauged. Glazed shutter made out of hollow section with sash bar gauged shutter including hinges, tower bolt, handle, grill made of 10 sqmm bar including two coat of synthetic enamel paint over shop coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast including plain/figured glass and wire mesh complete all as per details shown in drawing No CEPZ/TD-032/13 sheet No 1/1 & 2/2 including taking down existing unserviceable windows/ventilators of any type (wooden/steel) complete all as specfiied and directed.
Supply and fixing 2nd class Hardwood plain,solid, straight chowkats and frames, wrought, framed rebated solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
Material and labour for 18 to 20 mm thick PVC prelaimnated solid board with one side decorative choice laminated and other side balancing white including 3mm thick lipping equal to thickness of board as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed.
Suppy and fixing ball catchers with 8mm dia steel ball and brass body and stricking plate including letting in and fixed complete all as specified and directed.
Supply and fixing 40mm dia cupboard knobs fixed with nut, screw and washer of brass polished complete all as specified and directed.
Supply and fixing hasp and staple 100mm long, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
Supply and fixing continuous (piano) hinges 30mm width of flaps (when open), mild steel, bright finish or electrogalvanised complete all as specified and directed.
Supply and fixing stainless steel butt hinges of size 100mm long for fixing of pvc door shutter etc complete all as specified and directed.
Supply and fix aluminium, anodised, barrel tower bolts of extruded section, length of bolt 150mm complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium, anodised, barrel tower bolts of extruded section, length of bolt 200mm complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium handles, cast type, anodised 150mm complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed length of bolt 250 mm complete all as specified by Engr-in-Charge.
Supply and fix floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel rings with 50 mm dia and proportionate for part there off, with stainless steel brackets near to ends with stainless steel finials for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows including necessary fittings, complete all as specifed and as directed by Engr-in-Charge.
Welding in repairs n. exc 2.5cm in length thickness of metal to be welded n exc 6mm complete all as specified and directed by Engr-in-Charge.
Welding in repairs exc 2.5cm but n exc 5cm in length thickness of metal to be welded exc 6mm but n exc 9mm complete all as specified and directed.
Supply and fixing peg set of 4, brass chromium plated fixed on patti 30 to 40cm, fancy type, superior quality and fixed with screws complete all as specified and directed by Engr-in-Charge.
Supply & fixing brass door magic eye: resin lens +zinc alloy,top diameter: 31.2mm, botom diameter approx 24mm, pipe diameter approx 16mm total length approx 60mm, inner height approx 36mm application 35 to 60mm thick viewing angle 200 degree of surrounding without opening the door unique design ultra clear view and superior finish, wide angle best in class lens for all round visibility the outsider cannot hide any ware, the back cover protects from the outsider observing any movements inside easy to instal with inbuilt screw over a wide range of door thickness from 35 mm to 60mm etc required at site complete as directed by Engr-in-charge
Supply & fixing solid chromium plated heavy door chain (weight not less than 249 gms) with brass screws to any type of door shutter and frame complete all as specified and directed by Engr-in-Charge.
Taking up or down 15mm bore, steel tubing and connection complete all as specified and directed by Engr-in-Charge.
Supply & fixing 15mm bore steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
Fixing only 15mm bore old steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. (Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings)
Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed.
Supply & fixing 20mm bore steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
Fixing only 20mm bore old steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. (Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings)
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing, etc and making good, cutting not exceeding 10cm girth complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe all as directed by Engr-in-Charge.
Supply & fixing in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe all as directed by Engr-in-Charge.
Supply & fixing Rotational moulded polyethlene water storage tanks hoisted and fixed in position 500 ltr capacity all as specified in SSR Part I including new 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old broken water tanks, outlet & over flow pipe etc complete all as specified and as directed by Engr-in-Charge.
Fixing only existing Rotational moulded polyethlene water storage tanks hoisted and fixed in position all as specified in SSR Part I including 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and outlet & over flow pipe etc complete all as specified and as directed by Engr-in-Charge.
Supply & fixing Rotational moulded polyethlene water storage tanks fixed in repair three layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic bala screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms complete all as specified and as directed by Engr-in-Charge.
Fixing only existing Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (Minimum weight 20mm-210 gms) including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair ball valves 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe & fixed. (min. weight 20mm-210 gms)
Supply and fixing in repair PVC tank lid/cover for water storage tank of 500 ltrs capacity with fixing arrangement complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair 15 mm bore long body CP bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down , high pressure for iron pipe mpete all as spd & directed by Engr-in-Charge.
Supply and fixing in repair 15 mm bore stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair stop valves (ISI marked), 15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup(concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm bore complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for in repairs CP pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shank nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs 15mm bore brass wall mixer 3-in-1 system with provision for both hand shower and overhead shower complete with 115mm long bend pipe, connecting legs & wall flange mixing hot and cold water, screwd down for 15mm dia iron pipe complete all as specified and as directed by Engr-in-Charge. (Note:- Hand shower & over head shower will be measured and paid separately).
Supply and fixing in repair hand shower dia 105 mm round shape single flow with air effect (ABS BODY & FACE PLATE CHROME PLATED) with rubit cleaning system including shower flexible tubes 8 mm dia & 1.5 m long with nuts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs brass CP shower rose 125mm size including fixing to GI pipe or union complete all as specified and directed.
Supply and fixing in CP brass towel ring 20mm dia, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge.
Supply and fixing in tubular towel rail, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge.
Supply and fixing stainleess steel towel rack 600 MM long with lower hanger, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge.
Supply and fixing in PVC Coloured bathroom cabinet looking mirror divided into shelf overall size 622mm x 432mm complete all as specified and as directed by Engr-in-Charge.
Supply and fixing soap dish of stainless steel fixed to wall with aluminium screw, complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge.
Supply & fixing for corner glass shelf with bracket fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair Hand Shower (Health Faucet) with 8 mm dia,1.2 m long Long Flexible Tube Chrome Finish & Wall Hook for Water closet complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair vitreous china wash down water closet pan including P or S trap of bore 125/110 mm (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat cover, white or in matching colour, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
Supply and fixing in repair viterous china squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and as directed.
Supply and fixing in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specfied and as directed.
Supply and fixing in repairs Viterous China wash hand basin, white, flat back, size 550x400mm excluding taps etc but including brackets, cutting for and pinning in ends of brackets or erecting stand including waste coupling complete all as specfied and as directed.
Supply and fixing sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mm and bowl size 410mmx330mmx 160mm including 40mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed.
Supply & fixing in repair 32/40 mm bore PVC waste pipe flexible with minimum length 800mm complete all as specified and directed.
Material & Labour for stainless steel plate rack(Utensil Rack) of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings/nuts,bolts & washers complete all as specified and as directed.
Supply and fixing 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes.
Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm
Supply and fixing PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed.
Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.all as specified and directed.
Supply and fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED)
Supply and fixing PVC (SWR) bends any radius 75mm dia all as specified and directed.
Supply and fixing PVC (SWR) Single or double "T" where ever required any radius 110mm dia all as specified and directed.
Supply and fixing PVC (SWR) Single or double "T" where ever required radius 75mm dia all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 110mm dia all as specified and directed.
Supply & fixing in repairs 75mm PVC floor trap, ISI marked with CP grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required Internal dia of pipe in 75mm/100mm complete all as specified and as directed.
Supply and fixing sand Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, laid in trenches or in floors bore of pipe in 100mm complete all as specified and as directed.
Supply and fixing sand Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, laid in trenches or in floors bore of pipe in 75mm complete all as specified and as directed.
Supply and fixing sand Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, fixed to walls bore of pipe in 75mm complete all as specified and as directed.
All as per item 144 above but except pipe. (Note: - Old Cast iron soil, waste and vent pipes any type retrieved from dismantling shall be used)
Supply and fixing sand Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, fixed to walls bore of pipe in 100mm complete all as specified and as directed.
All as per item 146 above but except pipe (Note: - Old Cast iron soil, waste and vent pipes any type retrieved from dismantling shall be used)
Material & Labour cast iron bends (ISI marked) (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 100mm, complete all as specified and as directed by Engr-in-Charge.
Material & LabourCast iron bends (ISI marked) (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 75mm, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing Articles n exc 5 kg each Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire & soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters & similar articles complete all as specified and as directed by Engr-in-Charge.
Material & Labour two coats of black japan painting on new iron/steel surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new surface all as specified and directed.
Material & Labour for applying two coats of black japan painting on old iron/steel surfaces of any description over 10 cm in width or girth not otherwise described including preparation of old surface all as specified and directed.
Supply and fixing Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing/cooler stand including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
Removing of MS gate and re fixing including increasing height of gate with hold fast as directed nby Engr-in-charge.
Cutting holes in brick walls built in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required,Depth of embedded portion of holddfasts or lugs measured from the face of the jamb into the wall exc half brick but not exc one brick complete all as specified and directed.
Material & Labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
S& F Steel rolling shutters 1.25 mm thick with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete, gear operated type with bevel gear box and crank handle
Material & Labourfor post construction ATT to points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed
Material & Labourfor providing and injecting chemical emulsion for post constructional anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling 12mm dia upto 300mm deep and 300mm centre to centre and plugging holes etc in apron /plinth protection all as specified in IS Code 6313 Part-3:2001 and as directed.
Material & Labourfor post construction ATT treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed
M&L for providing 35mm thick precast louvers and jallies in repair made of cement concrete (1:2:4) type B0 using 12.5 mm graded crushed stone aggregate & fixed in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
Material and labour for chicken wire mesh galvanised steel wire 0.91 mm dia fixed with tinned tacks or wire staples and size of mesh 25 mmx 25 mm complete all as specified and as directed by Engr-in-Charge.
Chipping, removing carefully concrete work by low impact hammer, breaking without damaging the structrue & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge.
Cleaning existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and applying two coats of rust remover or alkaline rust converting primer and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, with time interval of 1hour between the coats use in cols, beam and slab all as specifid and directed by Engr-in-charge.
Applying a coat of anticorosive polymer modified cementitious for corosion inhibiting protection of reinforcement in two layers of total thickness of 2mm. The second coat shall be applied after 2-3 hours of first coat in cols, beam and slab all as specifed and directed by Engr-in-charge.
Rebuilding the section of damaged RCC to its original size in thickness exceeding 40mm but not exceeding 100mm by providing and casting with pre-packed dual shrinkage compensated micro concrete of minimum grade of M-40 including providing and fixing of water tight fair faced finish shuttering of minimum 18 mm thick with supporting framework, mixing, placing, de-shuttering, leveling the surface by grinding off cementitious slurry of construction joints in cols, beam and slab all as specifed and directed by Engr-in-charge.
Rebuilding the section of damaged RCC members to its original size in thickness up to 40mm by providing and applying ready mixed duel shrinkage compensated thixotropic mortar (PMM) of minimum grade M-40 including all lead lift, mixing by addition of water only as per manufacture's instructions, levelling the surface, curing including necessary form work etc complete all as specified and as directed by Engr-in-Charge.
Material & Labour for rectify surface cracks on plastered walls in following sequence complete :- (a) Chipping off the damaged portion to obtain a sound surface with straight edges (b) Washing the area with water. (c) Apply cement slurry on the surface (d) 10mm thick plaster in CM 1:3 with water proofing compound using recron fiber 3S (Mixing & application as per manufactures intructions) (e) Allow the repaired patch to cure adequately
Material & Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in surface channels and drains complete all as specified and as directed by Engr-in-Charge.
Material and labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds mitred, stopped ends etc complete all as specified and directed by Engr-in-Charge.
Material & Labour for Rectify the dampness on internal walls where dampness occur in following sequence through manufacturer / authorised applicator of the manufacturer complete :- (i) Cleaning of surface with the help of various equipments wire brush etc and surface to be made dirt, oil and foreign particle free (ii) Repair of surface as and where required with Polymer Modified mortar using Sika Raintite (iii) Applying a coat Sika Raintite (iv) Applying two coat of SIKA Top Seal 107 all as directed by directed by Engr-in-Charge.
PATH WORKS: Material & Labour for hard core of broken stones or boulders of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge.
Material & Labour for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. (Note: Surfaces of concrete to be finished even and rough to receive the topping layer)
Material and labour for coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80 mm thickness, M-35 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed. (Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by GE).
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose of soil complete all as specified & as directed by Engr-in-Charge. (Note: Any dammage occurred to water supply pipe line/ electric cable/existing drain/sewage line during excavation work will be make good as per existing specification with extra cost to Govt).
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed by Engr-in-Charge.
Supply and fixing for Pre-cast cement concrete block masonry (Kerb stone) 1:2:4 Type B-1 using 20mm graded crushed stone aggregates with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Material and labour for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed.
Supply and fixing Cement coloured concrete tiles 30cm x 30cm, 20mm thick with glossy finished, with grey cement & pigment machine pressed; set, jointed & pointed in neat cement slurry in floors ,path & cut polished over and including 20mm thick secreed bed or bedding in CM 1:6 complete all as secified and as directed by Engr-in-Charge.
SEWAGE DISPOSAL: Demolition of roofs, floors (other than ground floors), beams staircases, landing, chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed. (Note:- Demolition will be done only by mechanical cutter).
Material and labour for for precast reinforcement cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for manholes/septic tank etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and as directed. (Note: Reinforcement shall be measured and paid separately).
Material and labour for mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster of any description and thickness on walls etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed by Engr-in-Charge.
Material and labour for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, finished surface even and smooth without using extra cement .(Note:- WPC shall be measured and paid separately)
Material & Labour for 150mm dia RCC pipes, class NP-3, laid and jointed complete with collars including demolition and breaking up drain pipes in cement mortar including demolition of PCC bedding and hunching complete all as specified and directed by Engr-in-Charge.
Material & Labour for concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for bore of pipe 150mm complete all as specified and directed by Engr-in-Charge.
Material & Labour for 200mm RCC pipes, class NP-3, laid and jointed complete with collars including demolition and breaking up drain pipes in cement mortar including demolition of PCC bedding and hunching complete all as specified and directed by Engr-in-Charge.
Material & Labour for concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for bore of pipe 200mm complete all as specified and directed by Engr-in-Charge.
Material & Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in surface channels & drains,benching of manholes complete all as spd and directed by Engr-in-Charge.
Material & Labour for cutting into existing manholes (150mm dia pipe) for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch cahnnel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate & smooth finished reforming benching as required all as spd and directed by Engr-in-Charge.
Internal Electrification: Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, sketch fitting, ceiling roses, lamp holders, brackets, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-Charge. (Note:- The damaged surfaces to be made good with plastering (1:6). & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deemed to be included in quoted rates and nothing extra on this account shall be admissible).
Material & Labour for point wiring with 1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) of suitable 20mm size with all accessories having thickness not less than 1.8mm incl sheet steel/ CI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts.
All as per Srl item No 193 here-in-before but for one 5 pin 5 Amp socket outlet point on inependent board controlled by one switch SP, one way 5 Amp, 240Volts.
All as per Srl item No 193 here-in-before but for one 5 pin 5 Amp socket outlet point on same board controlled by one switch SP, one way 5 Amp, 240Volts.
All as per Srl No 193 above but for call Bell point complete all as specified and directed by Engineer In Charge
Material & Labour for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet, including 2.5 sqmm single core PVC insulated unsheated multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chases for concealed piping and making good disturbed surface finishing the surface to match with the existing surface complete all as specified and directed. (Note: (a) Insulation test of point wiring (b) colour coding is to be maintained).
All as per srl item No 197 here in above but using 4.00 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 4 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead for geyser point complete all as spd and directed by Engr-in-Charge.
Material & Labour for point wiring for one light/one fan controlled by one switch with 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit ISI maked heavy duty for one light fan/bell point controlled by one switch including suitable MODULAR cover plate and MODULAR metallic boxes of suitable way matching with surrounding including PVC green insulated unsheathed 1.5 sqmm multistrand copper conductor FRLS cable as continous earthwire and connecting to earth duly, complete all as specified and directed.
All as per srl item No 199 here-in-before but call Bell point complete all as specified and directed by Engr-in-Charge.
All as per srl item No 199 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 199 here-in-before but for 3 pin 5 amps socket outlet on independent board complete all as specified and directed by Engr-in-Charge.
All as per srl item No 199 here-in-before but for 15/16 Amps socket outlet on inependent board with 2.5 sqmm copper conducter FRLS cable and 2.5 sqmm PVC insulated unsheathed coper onductor cable FRLS (Green Colour) as earth lead complete all as specified and directed by Engr-in-Charge.
Supply & Fixing switch piano flush button single pole one way 5 Amp AC 240 volts, all as specified and as directed by Engr-in-Charge.
Supply & Fixing Bell push flush type 5 Amp 240 volts complete all as specified and directed by Engr-in-Charge.
Supply & Fixing switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed by Engr-in-Charge.
Supply & Fixing socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed by Engr-in-Charge.
Supply & Fixing socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed by Engr-in-Charge.
Supply & Fixing lamp batton angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed by Engr-in-Charge.
Supply & Fixing for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed by Engr-in-Charge.
Supply & Fixing Modular switch 1 way 6 A, 1 module complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Modular switch 1 way 16A, 1 module complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Modular fan step regulator 120W-2 module , complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular bell push 6 A, 1 Module, Complete all as specified and directed by Engr-in-Charge.
Supply and fixing of ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed by Engr-in-Charge.
Supply & Fixing bell AC,230 Volts, Single pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing mirror LED, 10 watt, 60 cm long light, prewired with all accessories including lamp and connected to ceiling rose using PVC insulated and overall sheathed flexible copper conductor 3core cable of size 0.50Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and Installation of the electric water storage heater of ABC body type 25 Ltr capacity 5 Star rating, vertical type thermally insulated MS tank with titanium glass line coating inside, heating element of power 2KW with anti corrosive, magnesium anode, NRV thermostat, indicators and temperature adjustable knob complete all as specified and directed by Engr-in-Charge.
Supply & Fixing LED smart Lamp, B22 type ,9 watt,complete all as specified and directed by Engr-in-Charge.
Supply and fixing 20W surface/wall mounted batten LED luminair, extruded aluminium housing with PC diffuser and ind electronic driver with high efficiency long, PF > 0.95, luminous efficacy > 100 lumens/Watt complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and direceted by Engr-in-Charge.
Supply and fixing in Energy saving, surface mounted, wall light LED luminaire 9W with PDC aluminium housing and polycarbonate diffuser globe shape (opal) B22 base with IP 66 protection complete including connecting up with three core twisted flexible copper conductor 0.5 sqmm cable complete as specified and as directed by Engr-in-charge.
Supply and fixing in Energy saving, surface mounted, bed side lamp LED luminaire 3 W polycarbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible copper conductor cable 0.5 sqmm of all as specified and as directed by Engr-in-Charge.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light made up of high grade polycarbonate material moon shape (opal) of size 200 mm (min) with retrofit LED lamp B22 base IP 65 protection with impact and corrosion resistant complete with driver and lamp complete as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible copper conductor cable of 0.5 sqmm suitable size complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling fan by disconnecting the electric connection and dismantling the blades complete all as specified and as directed by Engr-in-Charge.
Rehanging only of ceiling fan and connecting up including provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.5 sqmm from ceiling rose or connector to fan including minor repairs such as replacement of locking pin, reel insulators, bolts, nuts etc and applying colour one coat of synthetic enamel paint with spray gun of required colour all as specified and directed by Engr-in-charge.
Supply and fixing PVC Exhaust fans Single phase, 230 volts 250 mm size and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high including cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as specified and directed by Engr-in-charge.
All as per item No 229 here-in-before but MS ventilating fans 300 mm size complete all as specified and directed by Engr-in-charge.
Supply and fixing and connecting five star rated with brushless direct current motor (BLDC) ceiling fan 230 volts,single phase of 1200mm sweep double bearing type with including down rod,canopy cover fan regulator etc and connecting with 3core flexible copper conductor of 0.5 sqmm and including writing of MES No with black enamelled paint as per directed by Engr-in-Charge.
Supply & fixing of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
Supply & fixing of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including cutting suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
Supply and fixing MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp all as specified and directed by Engr-in-Charge.
Supply and fixing MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 6-40 Amp all as specified and directed by Engr-in-Charge.
Material & Labour sheet metal enclosure with MCB distribution board single pole and neutral with a two pin earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps complete all as spd and directed by Engr-in-Charge.
Taking down carefully of existing unserviceable surface/concealed sub main wiring any type complete all as specified and directed by Engr-in-Charge.
Material & Labour for sub main wiring with 2 run of single core, 6 Sqmm FRLS PVC insulated and unsheathed, multi starnded copper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm FRLS PVC insulated and unsheathed copper conductor cable in green colour as earth conductor connected to common earth dolly, drawn in and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8mm (ISI marked) with and including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface (Note: Two run of submain wire (phase and neutral), and one run of earth including PVC conduit and accessories will be measured as one run).
Supply and fixing distridution board iron clad vertical DB double door with IP-43 protection and mechanical strength as IK-09 suitable for MCCB as incomer an MCB as outgoing 415V 3Phase 50Hz 12 Way with appropriate size of copper bus bar and neutral link complete with complete all as specified and directed. Note: (MCBs & MCCB's will be measured and paid saperately)
Supply and fixing MCCB 415V,16KA, 4 Pole of rating 63 Amp all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB 415V,16KA, 4 Pole of rating 100 Amp all as specified and directed by Engr-in-Charge.
Supply & fixing secuirty light fitting energy saving high efficiency LED street light fitting 20 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length not less than 1.5 mtr fixing with clamp etc and making connections using flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
Material & Labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. (Note :- The rate quoted include cost of min 7.5 metre earthing wire)
Taking down single/ three phase electric meter after disconnecting electric connection & refixing in same or other location properly & making connection with 4 Sqmm, 3 core PVC insulated flexible copper conductor & making it in working condition complete all as specified and directed.
Ext Elect Supply : Taking down of old unserviceable LT cable any size from pole and bldg DB after disconnecting complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5core all as specified & as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as specified & as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4core all as specified & as directed by Engr-in-Charge.
Material & Labour for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified & as directed by Engr-in-Charge.
Material & Labour for old size brick covering the cable with width equal to length of brick as protection to cable with well burnt sub class 'B' bricks laid complete all as specified & as directed by Engr-in-Charge.
Note: The Schedule of credit has been attached in tender in Pdf formate and amount of credit schedule i.e Rs 13,86,168.20 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
SRM BUILDERS AND ENGINERS PVT.LIMITTED
M/S Satpal and co.
JAGSON CONSTRUCTIONS LTD
Sanjay Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .