Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
16 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (CD-III)
East Campus Maintenance (Residential Area Maintenance) , IIT DELHI
Construction of Temporary structure (double height- 5.5m high ) for JATC project (Mechanical Engineering Department) in academic area at IIT Delhi
2021_IIT_620895_1
IITD/ WORKS(SP-3415)/2020
Open Tender
Miscellaneous Works
Works
120 days
IIndian Institute of Technology Delhi
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Registrar IIT Delhi
Exempted
22 Mar 2021
5 Mar 2021
17 Mar 2021
5 Mar 2021
16 Mar 2021
5 Mar 2021
90 days
Amount
Civil Items
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, fnishing and reinforcement- All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S.pressed butt hinges bright finished of required size with necessaryscrews.
Second class teak wood
30 mm thick
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
Fixed to steel windows by welding
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Electric resistance or induction butt welded tubes
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge.
52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
40 mm wide and 4 mm thick
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Gutter (600 mm over all girth)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing 10 mm thick non-asbestos multipurpose cement board reinforced with cellulose fiber manufactured through autoclaving process (high pressure steam cured) as per IS: 14862 of Everest industries Ltd or equivalent make, over the existing MS frame work ( to be paid in basic items) with 25 mm counter sunk ribbed hard screws @ 200m center to center.
Electrical Items:
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Make of Wire: Havells/ Finolex/ Polycab)
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Make of Wire: Havells/ Finolex/ Polycab)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (Make of Wire: Havells/ Finolex/ Polycab)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel conduit/ FRPVC Trunking as required. (Make of Wire: Havells/ Finolex/ Polycab)
3 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Make: Legrand/ Havells Crabtree/ L&T/ Wipro North West/ Schneider)
5/6 A Switch
15/16 A Switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make: Legrand/ Havells Crabtree/ L&T/ Wipro North West/ Schneider)
6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Make: Legrand/ Havells Crabtree/ L&T/ Wipro North West/ Schneider)
Providing and fixing FR PVC trunking without cover of (105mm x 50 mm) size on existing wall etc. as required. (Make: Legrand)
Providing and fixing following assoceries on the existing FR PVC trunking etc. as required.
FR PVC trunking full cover width 85 mm (Make: Legrand)
End Caps (Make: Legrand)
6/8 Module arteor frame for 85 mm cover (Make: Legrand)
Flate angle (Make: Legrand)
Internal angle (Make: Legrand)
External angle (Make: Legrand)
Body Joint (Make: Legrand)
Cover Joint for 85 mm width (Make: Legrand)
Modular 16/20A switch on the existing modular plate and switch box/channel including connection. (Make: Legrand)
Modular 6/16A multi socket on the existing modular plate and switch box/channel including connection. (Make: Legrand)
Supply and installation of recess/surface mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 36 Watts, Output lumens not less then 3300lm; CCT not less then 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20. (Make: Panasonic/Philips/Bajaj/ Halonix/Havells)
Supply and installation of recess/surface mounting round/square LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 12 Watts, Output lumens not less then 650lm; CCT not less then 5700K; slim profile surface mounted down light square/round type; Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20. (Make: Panasonic/ Philips/ Bajaj/Halonix/Havells)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make: Havells/ Atomberg/ Bajaj/Orient/Crompton)
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply and Installation of 250 mm sweep suitable for operation on 230V, 50 Hz, AC supply exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Make: Havells/ USHA/ Bajaj/ Orient)
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(Make: L &T / Schneider / Legrand / Havells)
100 A,30KA,FP MCCB
125 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (matter: AC / Normal / Emergency Power) etc. as required . (Make: L &T / Schneider / Legrand / Havells)
8 way , Double door
12 way , Double door
Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps 4 Pole 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) including sign writing on DB (matter: AC / Normal / Emergency Power) etc. as required . (Make: L &T / Schneider / Legrand / Havells).
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supply and installation of SS enclosure for housing incomming MCCB 4P, of appropiate size with incomming and outgoing opening, suitable to accommodate upto 70sqmm, 3.5 core aluminium armoured cable,with louvers for heat dissipation and mounting hole for easy wall mounting. (matter: AC / Normal / Emergency Power) etc. as required . (Make: L &T / Schneider / Legrand / Havells)
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (matter: AC / Normal / Emergency Power) etc. as required . (Make: L &T / Schneider / Legrand / Havells)
Single Pole, 10A
Single Pole, 16A
Single Pole, 25A
Single Pole, 32A
Double Pole, 16A
Double Pole, 25A
Double Pole, 32A
Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L &T / Schneider / Legrand / Havells)
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L &T / Schneider / Legrand / Havells)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (Make: L &T / Schneider / Legrand / Havells)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (Make: L &T / Schneider / Legrand / Havells)
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Make: L &T / Schneider / Legrand / Havells)
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Make: RK Smelting Enterprise/ Industrial perforation/ Technofab/ Indiana Cable Trays)
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Make: RK Smelting Enterprise/ Industrial perforation/ Technofab/ Indiana Cable Trays)
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Make: RK Smelting Enterprise/ Industrial perforation/ Technofab/ Indiana Cable Trays)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 x 25 sq. mm size on cable tray/ open duct/ wall as required. (Make: Havells/ Skytone/ Gloster/ NICCO)
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 x 35 sq. mm size on cable tray/ open duct/ wall as required. (Make: Havells/ Skytone/ Gloster/ NICCO)
Suplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 x 25 sq. mm size in GI pipe as required.(Make: Havells/ Skytone/ Gloster/ NICCO)
Suplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 x 25 sq. mm size in GI pipe as required.(Make: Havells/ Skytone/ Gloster/ NICC
Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 25 sq. mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 35 sq. mm (32mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying, Installation, testing & commissioning of energy efficient LED compound light equipped with power coated PDC alluminium body & secondry optical lens for superior light distribution with energy efficient electronic driver with following features:- 130-300 Vac, 50Hz, wattage not more then 30 Watts, efficancy not less then 110 Lm/W, CCT 5700K, Nominal surge protection 2.5 kV, Power factor not less then 0.9, Minimum IP protection 66 etc. in suitable size GI pipe with reducer, GI saddle, bracket for proper fixing as required. (Make: Panasonic/Philips/Bajaj)
Supplying and fixing of 40 mm dia medium G.I. pipe of 1.5 meter long L type on surface of wall fitted with GI/MS bracket with reducer etc. complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (Make: AKG/BEC/M-Kay/ Steel Kraft)
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Agni/GST/Cooper/Bentel/ESSAR/Honywell/Bosch)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Make: Agni/GST/Cooper/Bentel/ESSAR/Honywell/Bosch)
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. (Make: Agni/GST/Cooper/Bentel/ESSAR/Honywell/Bosch)
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Make: Agni/GST/Cooper/Bentel/ESSAR/Honywell/Bosch)
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc. complete asrequired. 4 Zone Fire Alarm Panel, fully confirm IS 2189, Suitable for operation on 230V AC/ 24V DC supply, Battery backup with built in charger, Fire/fault status in unabiguous colored LED indications, 16 x 2 line dot matrix LED display, Zone wise fire, open, short LED indications, External S/W to test each zone fire, open, short status manually, External S/W for reset, silence, lamp test, Zone isolation faculity with loop voltage cutoff,Relay O/P for acutators, Mains on, System on, Charger on, visual indications, Battery Low & common fire indications, Auto dialer Attachable facility, enough inside space for battery, Attachable with all type of fire detectors complete as required.(Make: Agni/GST/Cooper/Bentel/ESSAR/Honywell/Bosch)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Make: Havells/ Finolex/ Polycab)
BASU DEV ROUT SANITATION
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .