Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.5 L+₹73,999.50 (3.56%)Rejected-Finance MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.7 L+₹97,801.50 (4.71%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹24.8 L+₹4.1 L (19.6%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹27.0 L+₹6.3 L (30.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
6 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO ESH BLDG NO P-31 (ESH-04) AND P-32 (ESH-05) SPL REPAIR TO BLDG NO T-144 AT MENDHAR AND SPECIAL REPAIR (E M) TO BLDG NO T-57 AND T-58 AT BDE CAMP IN THE AOR OF STN HQ BG UNDER GE 881 EWS
2024_MES_641140_1
GE/PNH-71/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹74,000
Yes
28 May 2024
7 Feb 2024
8 Mar 2024
7 Feb 2024
6 Mar 2024
21 Feb 2024
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in path/hardstanding/floor finished surface even and smooth without using extra cement, complete all as specified and directed.
Forming contraction (dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound grade A, complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 with mixing of liquid water proofing admixture @ 200 ml/kg of cement and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately
M&L for 10mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 5mm thick rendering on ceiling in CM 1:3 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of cement base paint over a coat alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered / unplastered surface of wall including cornices pilaster etc, and applying two coats of oil bound distemper over and including 1 mm thick wall care putty, complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatement from wall plaster and applying two coats of oil bound distemper white or any tint, over and including 1 mm thick wall care putty, complete all as specified and directed.
M&L for complete removal of existing treatement from wall surface incl cornices and chajja and applying two coats of cement base paint, complete all as specified and directed.
M&L for preparation of old decorated ceiling surfaces and applying two coats of white wash complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated or old steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Supply only liquid water proofing admixture complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint, laid in floor/walls as soil pipe including clamps, complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and taking down tarfelt/cement plaster and removing demolished materials at the dist of n exc 50 m, incl dismentling existing lightening conductor and refixing in same location incl repair/replacement if not working after completion of roof treatment, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in roof padding, complete all as specified and directed.
M&L for rendering 10mm thick cement mortar 1:4 in concrete, brick surfaces incl finishing even and smooth without using extra cement to receive roof treatment, mixed with liquid water proofing compound @ 200 ml/kg of cement, complete all as specified and directed. Note: WPC shall be measured and paid separately
M&L for water proofing roof treatrment with and incl priming surfaces and applying heavy treatment (for severe conditions except felt), and applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application and applying a coat of aluminium paint over APP membrane complete all as specified and directed by Engr-in-Charge.
M&L for writing letters and figure (block roman italic or indian) not exc 30 cm lenth with synthetic enamal paint incl preparation and repair of plate complete all as specified and directed by Engr-in-Charge.
S&F 0.56 mm thck plain, Aluminium sheeting of Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed by Engr-in-Charge.
M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-Charge.
Taking down steel door and refixing after repairing the hinges by welding/adding necessary steel plates not exc 0.10 sqm at site complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S&F box type steel window glazed and gauged (combination) with side hung/ top hung shutter including box type/ projecting type hinges and steel peg stay, handle and locking arrangement (02 Nos MS tower bolts 150 mm long for each leaf) and frame made out of 1.25mm thick pressed steel frame complete including necessary cooler arrangement in window and guard bars including one coat of red oxide zinc primer and all as per sample kept at GE office and complete all as specified and directed by Engg-in-charge.
S&F galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or wooden beads, in square n exc. 0.5 Sq.m pane, complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing with neat cement slurry @ 3 kg per Sqm complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 Sqm but n exc. 0.38 Sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 Sqm but n exc. 0.38Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for reinforced cement concrete in 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and alike structure, complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), incl fair finishing the surfaces, complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for walling of random rubble stone/boulder masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per item No. 39 above, but except stone complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of cement concrete (reinforced) in any description, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
M&L for rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 290 W(Gde E 165), quality B complete, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm complete all as specified and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building fixed or laid/inserted to timber/GI/aluminium framework fixed in ceiling with screws complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in base course or floor, finished even & fair to receive floor finishes, complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 54 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano flush type 16 Amp one way, (ISI marked), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
S&F new BLDC ceiling fan of 1200 mm sweep, min air delivery 210 CFM, 230 V, 50 Hz with service valur 6.00 BEE, 5 star rating, complete wilth blades, down rods, electronic fan regulator and incl all connecting accessories and incl taking down old existing fan complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair decorative wall light fixture made up of poly carbonate with lamp holder incl inverter bulb of capacity not less than 10 watt complete all as specified and directed.
Supply and fixing in repair LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughned glass and individual high power LEDs and heat resistant complete with driver including including LED strip, 5700 K, IP66 protection and impact resistance of IK 07 suitable for pole of OD 43 mm maximum including bracket of 40 mm dia, angle and fixing material complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 40 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core & including taking down old old unsv service cable connection, complete all as specified and directed.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in replacement of wall mounted fan 400 mm sweep, 220 volt AC, air delivery 95 Cum/min incl connecting up from ceiling rose or connector to fan, complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 6 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF063 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB SP 63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSPF063 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, vertical TPN double door (IP43), 4 ways built in bus bars suitable for 415 volts, AC, 50 Hz and suitable for FP MCCB as incommer and out going SP/TP MCBs , conforming to IS 8623 complete all as specified and directed. Note:- MCCB/MCBs shall be measured and paid separately.
S&F in repair MCCB 63amps, 4 pole, 415 volts, rupturing capacity , ICS + 75 %, including extended terminals, complete all as specified and directed. Note:- MCCB/MCBs shall be measured and paid separately.
S&F in repair submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade of size 6 Sqmm (nominal area) each and one single core 6 Sqmm cable as earth continuity conductor to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover complete all as specified and as directed. Note : Three runs of 6.00 Sqmm cable and one run of PVC conduit shall be measured as on unit
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 35 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed.
JAMWAL CONSTRUCTION CO
VIKAS ENTERPRISES
NATIONAL TRADING COMPANY
M/S KHAN TRADING COMPANY
M/S BHATT TRADERS
Modh Hafiz Khan
M/S RAHUL GUPTA
M/S SEVEN LAKE CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .