| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹27.8 L+₹2.1 L (8.13%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹28.6 L+₹2.9 L (11.2%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹26.6 L
EMD Value
₹53,140
Closing Date
17 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
Air Force Station Jammu
CA NO GE/AFJ-02/2023-24 ADDN/ALTN/IMPROVEMENT TO CERTAIN COOK HOUSE AND ADJACENT AREAS IN OFFICERS MESS,SNCO MESS,AIRMEN MESS , DSC MESS AND PROVN AND FIXING OF WALL MOUNTED METALIC BOARDS AT CERTAIN LOCATION AT AF STN JAMMU UNDER GE (AF) JAMMU
2023_MES_590225_1
CA NO GE/AFJ-02/2023-24
Open Tender
Civil Works
Item Rate
270 days
JAMMU
As per tender docuents
8 documents required · 8 mandatory
₹500
GE(AF) JAMMU
₹53,140
Yes
14 Jul 2023
19 Apr 2023
19 May 2023
19 Apr 2023
17 May 2023
3 May 2023
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)complete all as specifed and directed
Demolition of brick work or stone/ boulder masonry , bult in cement mortor incl all quoins, arches, pillars etcincluding depositing unservicable brick and stacking for reuse including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed.
Demolition of reinforced cement concrete as in slab, beam, etc complete all as specifed
Taking up or down steel tubing for 15/20 mm dia pipe and connections including cleaning for re-fixing all as spd and directed by Engg-in-Charge
Dismantling existing unservicable floor/wall tiles of any description including bedding/screed layer all as specifed.
Taking down chowkats or frames exc 1.5 sqm but n exc 4.0 sqm each with shutters (without taking off shutter from the frame) and removing complete all as specifed and directed
Material and labour for 15 mm rendering in CM 1:6 on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified as directed by Engineer-in-Charge.
RCC 1:2:4 type B-1 (20 mm graded crushed stone agg) as in plinth beam, lintel lintel and similar suspended work etc complete all as specified as directed by Engineer-in-Charge.
TMT steel bars of 10mm dia and over for reinforcement, cut to length, bend to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (anneled) not less than 0.9mm dia complete all as specified and directed.
TMT steel bars of 5mm to 8 mm dia and over and including 10mm dia as in stirrups, spacer and binders, cut to length, bend to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (anneled) not less than 0.9mm dia complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc beams also play as between fllor and beams complete all as specified and directed.
M&L 25mm thick Cement concrete type B-1,1:2:4 (20mm graded crushed stone aggregate) as in sub base of tiles floor finished etc complete all as specified and directed by Engr in charge.
M&L for colored non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:6 to match shade, pattern, laying etc of tiles as directed at site
Dismantling existing unservicable floor/wall tiles of any description including bedding/screed layer all as specifed.
M&L Vitrified tiles light shade 10 mm thick (Square or rectangular ) polished , area of each tiles exc 0.36 sqm but not exe0.42 sqm , in floors etc laid over 15mm thick screed bed in CM 1:4 set and jointed in neat cement slurry and pointed in whitr cement to match complete all as specified and directed.
M&L for 300mmx450mm x7 mm thick glazed ceramic tiles colored as in dado/ skirting and vertical surfaces set&jointed in neat cement slurry and pointed in colored cement over and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tilescomplete all as specified and directed.
S&F for glazed ceramic wall tiles iternity class having a size area exc 0.27 but n exc 0.45 Sqm each incl 10 mm thick cement mortar 1:4 to match the shade, pattern, laying etc of tiles complete all as specified and directed.
S&F in repairs 16mm dia of CPVC pipes SDR 11 & plain CPVC SDR 11 fittings. with all fittings; (ISI marked) such as brass elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs 20mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings. with all fittings; (ISI marked) such as brass elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints in trenches bore of pipe 110 mm with PVC clamps and saddles including taking down existing (SGSW/PVC) pipe and fittingscomplete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints trenches bore of pipe 75 mm with PVC clamps and saddles including taking down existing (SGSW/PVC) pipe and fittings complete all as specified and directed.
S & F PVC (SWR) bends of any radius bore of pipe 110 mm complete all as specified and directed.
S & F PVC (SWR) bends of any radius bore of pipe 75 mm
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 110 mm
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 75 mm
PVC (SWR) floor trap , plain with grating including jointing with solvent cement.
PVC (SWR) reducers 110mm bore.
S&F Vitreous china table top of size 480 x 370 x 110 mm Make CERA,CAT NO:CARMONA S2020162,EDGE 45 S Cat. No.: 91100 Hindware , FLS-WHT-5931 JAQUAR as approved by Eng-in-Charge.
S&F chromium plated popup waste coupling 32mm dia (half or full threaded ).Make cera,CAT NO:F8050351, Cat. No.: F860051 HINDWARE, ALD-727 Jaquar as approved by Eng-in-Charge
S&F chromium plated cockroach trap (100mmx100mm)with or with out waste hole flat border.Make:- Jainko ,CAT NO:SGJ-05 or equivalent in Hindware , Jaquar, perryware)as approved by Eng-in-Charge
S&F water closet wall hung p trap white or coloured 510 x 350 x 360 mm mm along with with Slim soft close seat cover and Concealed Cistern Set with Full Frame Make: CERA Model cat Part No (CIERRA S1043143, B1110111) Cat. No.: 92569 (P-22.5} Hindware , VGS-WHT-81953UF Jaquar as approved by Eng-in-Charge.
S&F in repair Brass CP Central Hole wash basin mixer for Hot and cold for 15mm bore with 450 mm braded connection pipe complete fixed to connection as specified cera cat no F1013451,Cat. No.: F570014 HINDWARE, FLR-5001B JAQUAR as approved by Eng-in-Charge.
S and F in repair 15mm dia bib tap with wall flange and aerator fancy type Chromium plated(CP) cera cat no F1013151, Cat. No.: F460003 HINDWARE, KUP-35037PM JAQUAR as approved by Eng-in-Charge.
Supply and fixing in repair angle valve with wall flange cromium Plated (CP) 15mm dia screwed both and iron pipe or for unions fancy type. cera at no F1013201, Cat. No.: F280004 HINDWARE, ALI-85053 JAQUAR as approved by Eng-in-Charge.
S&F in repair brass CP wall mixer ( 3 in 1) with arrangement for both telephonic hand shower and over head shower with bend pipe.mixer for hot and cold for 15mm bore complete fixed to connection as specified. Cera cat no F1099403.Cat. No.: F570016 HINDWARE, CQT-23281UPR as approved by Engr-in-Charge.
Supply and fixing in repair overhead Shower Rose 125 mm dia (5") with 200 mm (8 ") long shower arm and wall flange Cromium plated with arm suitable for 15mm dia pipe (as per sample approved by Engineer-in-Charge. Cera cat no F7010212AB,F7040104, Cat. No.: F160147 HINDWARE, BSH-1751 SHA-455L400 JAQUAR as approved by Engr-in-Charge.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long flexible tube and ABS wall hook including making connections and fixed in all respect as specified in position complete cera cat no F8030107AB, Cat. No.: F160110 HINDWARE, ALD-573 JAQUAR as approved by Engr-in-Charge.
S&F in repair towel rail 600mm long of chromium plated fixed with brass screws and plastic cleats Cera cat no F5002103, CAN-1111SM JAQUAR, Cat. No.: F450024 HINDWARE as approved by Engr-in-Charge.
S&F in repair towel rack 600mm long of chromium plated fixed with brass screws and plastic cleats Cera cat no F5006101, Cat. No.: F580008 HINDWARE, CAN-1181S JAQUAR as approved by Eng-in-Charge.
S&F in repair soap dish of chromium plated fixed with brass screws and plastic cleats Cera cat no F5003106, CAN-1131N JAQUAR, Cat. No.: F580004 HINDWARE as approved by Eng-in-Charge.
S&F in repair towel ring of chromium plated fixed with brass screws and plastic cleats. Cera cat no F5002105, CAN-1121BN JAQUAR, Cat. No.: F880007 HINDWARE as approved by Eng-in-Charge.
S&F in repair toilet paper holder chromium plated fixed with brass screws and plastic cleats. Cera cat no F5002110, Cat. No.: F880003 HINDWARE, ACN-1153S JAQUAR as approved by Eng-in-Charge.
S&F in repair corner type glass self large (300x300) with Chromium plated railing fixed with brass screws and plastic cleats. Cera cat no F5005103.Cat. No.: F880010 HINDWARE, ACN-1173 JAQUAR as approved by Eng-in-Charge.
S&F 10 mm thick bevelled edge glass as in shelves size and shape as required at site and directed by Eng-in-charge .(Note: Size of glass shelf shall not exceed 0.5 sqm each )
S&F stainless steel clamps capable of supporting glass shelves of max width 200 mm all as specified and as directed.
Supply and fixing optima 2D sliding shower partition wall to wall enclosure with two fixed glass and two sliding door 8mm printing glass opening size H 2000 x W 1501-2000 mm complete all as specified and as directed. Make: Cat part No Cat. No. JSE-CHR-OPT2D1520X of JAQUAR, SU83CWG-2024H19-CR 2001-2400 HINDWARE as approved by Engr in chage
S&F brass designer sliding bolt (heavy type) 250 mm size fixed in drawers or shutters as in cupboards complete all as specified and directed
S&F brass designer handles ( heavy type ) 150 mm size fixed in drawers or shutters as in cupboards complete all as specified and directed.
S&F brass designer tower bolt ( heavy type ) 150 mm size fixed in drawers or shutters as in cupboards complete all as specified and directed.
S & F exposed metal frame ceiling with 8mm thick PVC Laminated Gypsum board/ tiles 59.5x59.5 CM in size ,Gi frame powder coated of size 600 mm x 600mm grid with fasteners, supports, Hangers 4mm dia G.I (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I flat 40X3mm size 60mm longplugs to ceiling complete as per manufacturer instructions and as directed by Engr-in-Charge.
S&F in repairs mat finished nano granite/ italian marble area n exc 3.0 Sqm each including moulding complete all as specified and directed by Engr in charge.
M&L preparation of old existing aluminium/ wooden / PVC doors and windows applying two coat of synthetic enamel wood finished paint over a coat of primer etc complete all as specified and directed by Engr in Charge.
S/F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specifed and as directed by Engineer-in-Charge.
S/F solid PVC Door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, complete all as specifed and as directed by Engineer-in-Charge..
S & F in repairs pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping and benching for man holes and haunching around man holes frame for setting including weathering slightly rounded or chamfered angles and throating oncluding necessary form work all as specifed and as directed by Engineer-in-Charge..
S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including glazing by using 5mm thick plain sheet glass complete all as specified
S&F, 4.8 mm thick sheet glass ordinary quality and glazing with oil putty, wooden beat or fix in aluminium window shutter in square exc 0.5 sqm in each pane complete all as spd and as directed
S&F anodised aluminium powed coated window with glazed and wire mesh shutter sliding type aluminium open three track section having specific size of style ,top rails and bottom rails including anodised aluminium frame incl necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings complete and including glazing by using 5mm thick plain sheet glass and stainless steel wire mesh of dia 0.36 mm and aperture 1.40 mm complete all as specified and as directed Note :- S& F of 5mm thick glass & SS wire mesh are included in the items No payment will be made separately)
S&F aluminium anodised powder coating grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer -in- charge.
M&L preparation of new plastered surfaces of wall priming with alkali primer and applying two coats of cement based paint complete all as specified and as directed
Prepration of new plastered surfaces of wall and applying two coats of oil bound distemper with oil emulsion over a coat primer and 3mm wall putty complete all as specified and as directed
SCHEDULE 'A' PART-II (AREA DRAINAGE WORK)
Extra for forming fair finished channels or drains 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends complete all as specified and as directed
SCHEDULE 'A' PART-III (SEWAGE DISPOSAL)
Precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in cement mortar 1:6 complete all as specified and as directed
M&L for providing TMT bars 8mm dia cut to length, bend to shape required incl cranking, bending spirally for hooping for column hooking ends and binding with and including MS wire (annealed) not less than 0.90mm complete all as specified and as directed
Supply and Fixing of Reinforced concrete pipe class NP-2 laid and jointed complete with coller 150 mm dia complete all as specified and as directed
Concrete bed to drain pipes of 150mm bore in PCC 1:4:8 type D2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed
Supply and installation of grease separator plant suitable for underground installation. The Grease separator should be made from polyethelene for longer life. The grease separator should have nominal capacity not less than 2170 ltrs with Inlet/outlet socket of nominal dia of minimum 150 mm with grease storage capacity of minimum 415 ltrs and sludge storage capacity of minimum 1010 litrs. Total weight of grease separator should be minimum 128 kg with overall dimension of atleast 1320 mm x 2828 mm (Dia x Ht.) The grease separator should be capable of cleaning via shaft manhole cover, emptying via suction line nominal dia of minimum 65 mm and nominal pressure of 10 kg with couplings for two sided thread connection 75/75 mm for suction line, fire hose quick coupling 75 B and 2.5 inch black cap and counter flange with wfire hose quick coupling 75 B and 2.5 inch blank cap. Top cover of the grease separator plant should be made from concrete frame with cast iron having clear opening of minimum 600 mm diameter the cover should be odour free when close. The weight of the cover should be 145 kg and manufactured to meet 1.5 ton load class requirment. (the rate shall be included for supply & installation, provide three days training for operation/ function and transportation at site ) (Make & model no NS 10 grease separator plant (Make : ACO Lipumax PD/Hauraton/Kingspaw/Klargester) as per DIN EN 1825 and DIN 65 PN 10 suitable for underground installation.
SCHEDULE 'A' PART-IV (INTERNAL ELECTRIFICATION WORK)
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through existing PVC conduit concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
For one light point controlled by one SP switch
For one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No-4.02 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No-4.02 above but for one 3 pin socket out let, 16 Amps on Independent board with the copper cable 2.5 Sqmm size with 2.5sqmm copper earth wire
S & F socket outlet 5 pin, 6 amps flush type complete all as specified and as directed by Engineer-in-Charge.
Taking out of 1.5 ton split AC from room and storage AC gas after repairing of bldg fixing the same with complete accessories including testing and installation of AC indoor and outdoor unit complete all as specified and as directed
Disconnecting / taking down carefully existing LT panel board / feeder pillar box any type and capacity including all control switches, fitting , LT cable and fixtures and shifting the another place as directed by the Engr-in-Charge.
Supply, install, test and commission out door type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thich MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back open able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, TPN, Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve. Incoming MCCB- 200 Amp-02 Out going MCCB - 100 Amp -02, MCCB -63 Amp-01 and Volt meter and Amps meter including Indicator lamp three number complete all as specified and as directed .
Supply & fixing GI tubing light grade 50 mm bore on poles, under floors, road crossing etc complete all as specified and as directed
Supply, Laying, connecting including taking out testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing Cross sectional area 35 Sqmm 3 ½ core etc complete all as directed by Engr-in-Charge. Note:-Excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately.
S & F of Cable jointing kit suitable for 1.1 KV grade cable Straight through termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to70 sq mm complete all as specified and as directed
S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to70 sq mm complete all as specified and as directed
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts/11000 volts connecting and testing for any size complete as directed by Engineer-in-Charge Note:-Excavation,earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately
Taking out 4 Way DPX distribution Board and 12 Way MCB DB and shifting to another place including wiring complete all as specified and as directed
S&F sheet metal enclosures for MCBs, single pole and neutral, 08 ways 240 Volts double door type complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 Amps, 240 Volts complete all as specified and as directed
S&F MCB SPN upto 40 Amps ,240 Volts complete all as specified and as directed
Distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar. Make-Legrand Cat pt No 5077 30 or equivalent of make L&T / Merlin Gerin multi-9 complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 36 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. (Note: MCB's and MCCB will be measured and paid separately under relevent items)
S&F MCCB TPN 160 Amps ,415 Volts complete all as specified and as directed
S & F rigid non metalic PVC conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc.
Taking down carefully the existing aluminium/copper sub main wiring of any size and capacity and type by disconnecting from the either terminals complete with switches, sockets,ceiling rose, regulators etc by unscrewing and taken away from site complete all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanised iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Taking down and refixing of water heater storage type Geyser complete of capacity 25 liters removing 4 Nos bolts and fasteners including PVC washers at both ends, and refixing the same complete all as specified & directed.
Supply & fixing decorative handing ceiling light suitable lights with height suspension, creative and special shape white /warm white & nautural white colors of light complete with all accessoies all as directed by Engr-in-charge
Supply & fixing decorative wall mounting light with suitable LED lghts, Antique brass finish all accessoies all as directed by Engr-in-Charge
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 08/10 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge. Make:- Cat No : LUMILINEBS9WLED830SPCWH of HavellsCrompton Greaves/ Philips/Bajaj/Havells.
S & F Switch Modular (piano) flush button single pole one way 16 amps with suitable plate and cover complete all as specified and directed.
S&F Socket outlet flush modular (piano) type 5 pin 6 Amps with suitable plate and cover complete all as specified and directed.
S&F Socket outlet flush universal modular (piano) type 6 pin 6/16 Amps with suitable plate and cover complete all as specified and directed.
S&F Socket outlet flush universal modular (piano) type 6 pin 6 Amps with suitable plate and cover complete all as specified and directed.
Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Conduit will be measured and paid separately.
SCHEDULE 'A' PART-V (WALL MOUNTED METALLIC BOARDS WORK)
Applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces complete all as specified.
Framed brackets of angles or tees with web and flanges cut to shape,drilled and countersunk for screw,including bending and welding angles,as necessary,gusset plates,riveting etc not exceeding 10 Kg each brackets,confirming to Fe-290 Gde E-165 complete all as specified and ddirected by Engr-in-Charge.
Mild steel 1.60mm thick plain,black sheet in hearths,covering to door shutters,covering to door chowkats(frames) chulla hoods,water tanks water troughs,ducts,urinal troughs and funnels,etc cut to size edges beaded if directed,holes punched,including round headed if directed,holes punched including round headed screws,clout nails or riveets and fixed to wood or steel members etc,with plan 40mm lap joints or welded/riveted seams including bending,turning up,mitred angles stopped ends,outlets etc as required,complete all as specified and as directed by Engr-in-Charge.
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exc halfbrick but not exc one brick complete all as specified and directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zinc chrome primer, complete all as specified and directed by Engr-in-charge.
M & L for 450 x 400 x 3mm thick aluminium compressed yellow colour sheet with operating instructions(having 20mm heightof letter/alphabets) are to be printed in Red colour duly computerzied cut and fixed on yellow aluminum compressed sheet including cleaning decking passing or fixed on fire boards with steel screws or nut bolts or rebates complete all as specified and directed by Engineer-in-Charge. Note: (i) 400 x 450 x 1mm size metalic silver colour self adhesive sheet shall be casted over aluminium sheet as mentioned above and computerised printed operating instructions shall be made out from the red colour self adhesive material generally used for roads signs on highway (ii) one aluminium sheet including fixing arrangement one self adhesive sheet and printed operating instructions shall be measured and paid as one unit under this item.
Appendix 'A' WATER CO 2 FIRE EXTINGUSHER USED FOR Class 'A' fire all organic materials like wood paper grass,cloth etc. OPERATING INSTRUCTIONS 1. Take the extinguisher to the scene of fire and remove safely clips. 2. strike the plunger. 3. Direct the jet of wtertoscene of fire. 4. position the extinguisher at 45° angle. Appendix 'B' 09 LTR MECHNICAL FOAM EXTINGUISHER USED FOR it can be used for class'B' fire involving of paraffin petrol.solvents, alchol and the solid fuel which will liquefy under heat e.g Grease waxsolvents etc. OPERATING INSTRUCTIONS 1. Go as Near to the scene of fire as possible. 2. Shake it well 3. Strike the plunger with hard object. 4. Direct the jet at one point only APPENDIX 'C' DRY CHEMICAL POWDER (DCP) EXTINGUSHER USED FOR Class 'B' 'C' & 'D' fire e.g all flammable live electrical equipments etc except electronic equipments. OPERATING INSTRUCTIONS 1. Take the extinguisher to the scene of fire and remove safety clips. 2. Press the trigger and strike hard the plunger.
3. Direct the powder in the sweeping way and hold the trigger in the same way till the last. 4. Use the extinguisher in the wind direction. APPENDIX 'D' CO 2 FIRE EXTINGUISHER USED FOR Class 'B' 'C' & 'D' fire e.g all flammable live electrical equipments et except electronic equipments. OPERATING INSTRUCTIONS 1.Go as near to the scene of fire as possible and face to the scene of fire. 2. Revolve the control valve as required in anticlockwise direction or depending on desert. 3. Direct the jet at the base of the fire satarting at one edge and sweeping across the surface of the burning materials.
Writing letters or figures (Block Roman , Italic or Indian)not exc 30 cm high.any height,any type of surface is directed by Engr-in Charge.
SCHEDULE 'A' PART-VI (EARTH WORK AND COMMON NATURE ITEMS)
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out for foundation in hard/dense soil complete all as specifed and directed
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and not exc 1.5m depth , for foundation etc or for shafts ,manholes, etc not exc 10.00sqm on plan and not exc 1.5m depth and getting out in any type of soil
Brick work with sub class 'B' bricks (old size bricks) straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 )complete all as specifed and directed
M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded crushed stone aggregate) in foundations , filling and mass concrete) complete all as specifed and directed
M&L for rendering 15mm thick in cement and sand mortar 1:4 mixed with water proofing as per manufacture's instructions on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement)complete all as specifed and directed Note:-Water proofing compound shall be measured and paid separately
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
Plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of drain complete all as specified and as directed
Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping and benching for man holes and haunching around man holes frame for setting including weathering slightly rounded or chamfered angles and throating including necessary form work all as specified and directed.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed
SCHEDULE 'A' PART-VII (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The addn/altn work has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge of Air Force station Jammu.
Rakesh Kumar Malia
ANIKET TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .