Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.7 LAccepted-AOC NO 32 2ND FLOOR KAMATCHI APARTMENTS 10TH AVENUE ASHOK NAGAR CHENNAI 600 083 | CHENNAI | TAMIL NADU | 600083 | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | L2₹79.0 L+₹6.3 L (8.64%)Rejected-AOC NO 79 THENDRAL NAGAR MAIN ROAD AMBEDKAR NAGAR THIRUMULLAIVOYAL CHENNAI 600 062 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600062 | L2 | Rejected-AOC High rate tenderer | |
| 3 | L3₹79.0 L+₹6.3 L (8.65%)Rejected-AOC CHENNAI 600 035 | CHENNAI | CHENNAI | TAMIL NADU | 600035 | L3 | Rejected-AOC High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹56,500
Closing Date
19 Feb 2025, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Construction of New Building for Police Canteen and Go down at TSP V Battalion at S.M. Nagar Avadi in Chennai City
2025_TNPHC_524604_1
SE/CC/DB/206/2025
Open Tender
Civil Works
Lump-sum
240 days
S.M. Nagar, Avadi in Chennai city
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹56,500
7 Apr 2025
13 Feb 2025
21 Feb 2025
13 Feb 2025
19 Feb 2025
13 Feb 2025
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 m.
13.1) Filling with Excavated Earth
21.2) Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3) Supplying and fixing of Magnetic door catches
25) M.S.Holdfast
31) Weathering course
39) M.S Grills
41) Painting - New "iron work"
50.3) Supply and planting avenue trees
50.4) Providing Tree guard
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 a. 32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
b) 25mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
Electrical arrangemnt 69) Supplying and fixing 15Amps 3 pin plug type socket on a suitable MS box 16g
72) Box type Fibre Fan hook
74) Charges for fixing of "Fan"
76) Supplying and laying of 8SWG GI wire on wall below ground levels
78) Providing Earthing station using pipe electrode as per IS 3043 using 2.5m of 40mm and 1.0 m of 20mm B-class GI pipe(Type I)
86) Providing pre-constructional Antitermite treatment
Annexure 2.15) Supplying and filling stone dust
3.1.3) C.C.1:5:10 for Foundation & Basement
3.3.3) P.C.C. 1:8:16 using 20 mm broken brick jelly
6.2.2) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
8.2.4.1) Standardised concrete Mix M25 Grade Concrete a. In Foundation and basement
b. In Ground floor
c. First Floor
9.2.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a. In Ground Floor/Stilt floor
b. In First Floor
10.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) b. In Ground Floor/Stilt floor
c) In First Floor
11.2.2) Brick work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) a. In Ground Floor
12.2.2) Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick a. In Ground Floor
b. In First Floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raft beam, Raft slab etc.,
b.Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase waist, portico slab and other similar works.
c.For Square and rectangular columns and small quantities such as sunshade, parapet cum drops window boxiing, fin projection and other similar works.
e) Circular Column
21.5.1.3) Supplying and fixing of Solid Core Flush door Shutters with teakply on both side with teakwood lipping alround 35mm thick a) 1500x2400mm double leaf
21.5.2.2) Supply and Fixing Soild UPVC door Shutter with frame
21.7.3) Supplying and fixing of solid core flush door shutter of thickness 35mm a). door size 0.900 m x 2.400 (Single Leaf)
26.1) Flooring in C.C.1:5:10
28.1) Floor plastering in C.M. 1:4, 20 mm tk.
29.8.1) Glazed tiles using Grout (Tile Joint Filler), C.M 1:2, 10mm tk
29.9.1) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound
33.2.1) Plastering with CM 1:5 12mm thick finishd with neat cement
34.2.1) ) Plastering in C.M. 1:4, 12 mm tk.
35.2.1) Spl. Ceiling plastering in C.M. 1:3, 10 mm tk.
36.1) Cement mortar Border in C.M. 1:5, 12 mm tk. a. 150 mm wide
b. 75mm Wide
c. 50mm Wide
43.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.3) Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M25)
b) Augering 30cm dia
44.5.3.2) Providing Rain Water Harvesting well ring circular shape of 90cm dia, 60cm depth,50mm thick using M25 grade concrete
44.6) Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992- type 'A' for Rain water down fall pipe
50.5.1) Supplying. Fabricating and erection of M.S Scheme Name board
51.2) Supply and fixing of 1000 liters capacity HDPE water tank
52.4) 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5) Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1) Supplying and fixing of of 15mm dia half turn CP long body tap
54.2.1) Supplying and fixing of of 15mm dia half turn CP short body tap
56.3.1) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
57.1.2) Supplying and fixing of of E.W.C.(White) 500 mm with "P" or "S" TRAP with double flapped seat & seat cover
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75mm dia
58.4) Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1) Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm
60.1) PVC Nahani trap (4way/2way)
61.3) UPVC Non Pressure pipe of SN8 SDR 34 ( S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point
66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places
70.5.2) Supply and fixing of 4' long 18 W Crystal Glass LED tube Light with fitting
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.5) Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7) Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
82.3.1) Supply, fiing of 30W LED street light etc.,
84.3) Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
88.1.1) Supplying and laying of polished shahabad slab /stone, 20mm thick with machine cut efges of size 2'x'2' below (Grey colour) of approved quality for florring in CM 1:3 20mm thick and other similar works
98.5.1) TW double leaves shutter with Brass Fittings b. 1800X2400mm.with Brass fittings (Double leaf)
108.6.2) Run off 4 Wires of 6 sqmm PVC insulated single core multi strand
112.1) Supplying and fixing of 225 mm dia sweep AC exhaust fan
175.3.1) Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal /acrylic door cover flush type /surface type fitted with busbars and neutral links
207.3.1) Providing two coats of Plastic Emulsion paint including primer for inner walls
207.4.1) Providing two coats of Exterior Emulsion paint including primer for outer walls
207.4.2) Painting the ceiling with one coat Plastic Emulsion PAINT incl. Primer
255.2) Supplying and fixing of LED Bulb for suitable for fixing it to pendent / bakelite battern holder a) 9watts LED bulb
b) 12 watts LED bulb
255.6) Supply and fixing of Bulk Head fitting suitable for 12W LED Bulb
344.2) Supplying and fixing of Bevelled edge mirror 500 x 400 x 5.5mm
359.3.1) Concrete designer tiles flooring
366.3.1) Manufacturing, Supplying and Fixing of Stainless Steel Hand rails from finished floor level
367.1) Providing wooden Melamine polish for new wood work
451.3.2) Supplying and fixing of best approved quality of following CP water supply/Sanitary fittings a) CP Two Way Bib Cock with Health Faucet
465.3) Supplying and fixing of Push and Pull type steel Rolling shutters (Manually Operated up to 8m2 area)
832.5.2)Supplying and fixing in position of UPVC window of casement type( open) for all sizes
832.5.3)Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
KAVITHA BUILDERS (BID ID -1253775)
P.MANOHARAN (BID ID -1254366)
Bidder Name
P.MANOHARAN
KAVITHA BUILDERS
forserviz.com
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_624530.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .