Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
14 May 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have minimum eligibility criteria as given below: Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any of the following (by any Government organizations) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turn over of Rs.500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar Nature of Work "Any work in connection with signaling installation. The work shall include indoor wiring component also if tendered work involves indoor wiring alteration in the existing system. Note: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40/60 (as the case may be) criteria of similar nature of work."
26 conditions · 16 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Care In Submission of Tender : (In terms of Railway Board letter NO : 2017/CE-I/CT/4/GST dated : 23.06.2017)
(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/Integrated Goods and Services Tax Act, 2017 (IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderer will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under CGST/IGST/UGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UGST/SGST Act to railway immediately after the award of contract without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority
In case the successful tenderer is not liable to be registered under CGST/IGST/UGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority
S&T work for interlocking of LC gates with TVU>10000 in section Panipat-Rohtak & Rohtak-Ashthal Bohar-Rewari (HUN) section of Delhi Division of Northern Railway
Project_DLI_SNT_26_06
Project_DLI_SNT_26_06
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹5.0 L
14 May 2026
22 Apr 2026
30 Apr 2026
154 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,48,13,341.86 | ||
| — | 18000.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No. (NR/S&T/Con/1.1/97A) so as not to form a drain 0.3Mtrs wide & 1mtr deep on both side of the station along side the track. It shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes.Inspection : Site Incharge | — | — | — | 14,49,720 | |
| — | 45000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No. (NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of Northern Railway to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. Inspection : Site Incharge | — | — | — | 3,68,100 | |
| — | 104000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer. Inspection : Site Incharge | — | — | — | 8,44,480 | |
| — | 500.00 | — | — | ||
| "Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-RITES for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straightpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid under railway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizonta land vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. Inspection : RITES for DWC pipe " | — | — | — | 10,94,625 | |
| — | 160.00 | — | — | ||
| Supply and fixing of G.IPipe with 76.6 mmmaximum and 75.3 mmminimum outside dia. and3.6 mm thickness, as perspcn. no. IS-1239 (part-I)or latest if any, mediumgrade, perforated at adistance of 20 cm or lessof required length atculverts/bridges/along thecuttings, suitablyconcreted at both ends asper drg. no.NR/S&T/CON/1.4/97 orlatest. G.I. clamps of M.Sflats bolts and nuts to besupplied by thecontractor. G.I pipe andother associated materialto be inspected by RITES.Work at site will beinspected by SiteEngineer. Inspection : Site Incharge | — | — | — | 1,41,363.2 | |
| — | 60.00 | — | — | ||
| Concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic metres shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor. Inspection : Site Incharge | — | — | — | 1,80,885 | |
| — | 12.00 | — | — | ||
| Supply of Apparatus case steel Single with 'E' type locks and key ward No 42 complete as per drawing No.RE/S&T/ALD/SK/219/82 & 221/82 or latest. Handle should be at the rate of one each 4 nos. appratus case. Inspection : Site Engineer except for E Type locks which is to be inspected by RDSO | — | — | — | 2,64,902.04 | |
| — | 12.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Case single as per Drg. No (NR/S&T/ Con/2.7/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box.All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination.Inspection : Site Incharge | — | — | — | 1,40,985.6 | |
| — | 12.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and bakelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand andplastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn. (as applicable). Relays, ARA terminals only shall be supplied by the Railways. Inspection : Site Incharge | — | — | — | 73,858.32 | |
| — | 5.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. Inspection : Site Incharge | — | — | — | 24,445.7 | |
| — | 12.00 | — | — | ||
| Supply of apparatus case steel half with 'E' type locks and key ward No. 42 as per Drawing No. RE/S&T/ALD/SK/220/82 & 221/82 or latest. Handle should be at the rate of one each per 4 Nos apparatus case. Inspection: Site Engineer except for supply of E-Type lock which are to be inspected by RDSO. | — | — | — | 1,97,562.84 | |
| — | 12.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. Case half as per Drg. No (NR/S&T/Con/2.8/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to preventingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be suppliedby the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting thecable for termination.Insepction : Site Incharge | — | — | — | 65,945.04 | |
| — | 12.00 | — | — | ||
| Preparation of App. Case half involving wiring of relays: Preparation & fixing of bakelite hylum sheet 450x800x6mm and bakelite shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires , nuts and and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn. (as applicable). Relays, ARA terminals only shall be supplied by the Railways. Inspection : Site Incharge | — | — | — | 52,552.32 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. Inspection : Site Incharge | — | — | — | 7,402.26 | |
| — | 48.00 | — | — | ||
| Casting, concreting and curing of foundation of main signal as per Drg. No. NR/S&T/Con / 2.1/97 or latest.All material such as Anchor bolts cement, sand, aggregate to be supplied by the contractor.Inspection : Site Incharge | — | — | — | 5,64,496.32 | |
| — | 12.00 | — | — | ||
| "Fixing of 2-aspect of colour light signal CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an offset bracket and fitting ladder and guard to the post at the top Concreting ladder base and embedded into the ground with supporting bracket in the middle. Blanking of the ladder for a distance of 1 feet between the height 6'9""and 7'9""from the rail level by MS angle and MS sheet 0.6mm thick wherever required. This includes provision of wooden ( sal ) cross arm 1Mx1M for CLS unit prior to the commissioning, fixing of AC / DC lit LED Signal unit and hood on CLS unit, wiring the CLS unit and fixing the signal.Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian Railway published by Government of India & approved Drawings. All items for the above work except items mentioned in Annx B-2 shall be supplied by the contractor including following items. (i) U bolt for offset bracket. (ii) Wooden cross arm 1Mx1M (iii) MS sheet and MS angle for blanking of ladder (iv) Wire mesh guard, U-lock for unit , nuts and bolts etc for the following. (v) Supply and fixing of Signal Number Plate (Retro refractive type) with complete fittings as per standard railway practice. Inspection : Site Incharge" | — | — | — | 38,281.44 | |
| — | 12.00 | — | — | ||
| "Fixing of 3/4-aspect of colour light signal CLS surface base, bolting on the foundation. Erection of CLSpost with signal unit on the top or on an offset bracket and fitting ladder and guard to the post at the top Concreting ladder base and embedded into the ground with supporting bracket in the middle. Blanking of the ladder for a distance of1 feet between the height6'9""and 7'9""from the rail level by MS angle and MS sheet 0.6mm thick wherever required. Thisincludes provision of wooden (Sal) cross arm 1Mx1M for CLS unit prior to the commissioning, fixing of AC /DC lit LEDSignal unit and hood on CLS unit, wiring the CLS unit and fixing the signal. Elevation and distance of foundation fromtrack shall be in accordance with schedule of dimension for Indian Railway published by Government of India &approvedDrawings. All items for the above work except items mentioned in Annx B-2 shall be supplied by the contractor including following items. (i) U bolt for offset bracket. (ii) Wooden cross arm1Mx1M (iii) MS sheet and MS angle for blanking ofladder (iv) Wire mesh guard, U-lock for unit , nuts and bolts etc. for the following. (v)Supply and fixing of Signal NumberPlate (Retro refractive type) with complete fittings as per standard railway practice.Inspection : Site Incharge" | — | — | — | 48,263.4 | |
| — | 36.00 | — | — | ||
| Supply of CLS Signal post 4.6 Metre and ladder 4.5 M with bases ( 140mm dia, tubular) and platform confirming to IRS:S-6-81 and Drg. No 2011/M and for the ladder RDSO drg No. SA- 23153 (adv) or latest. Inspection : RITES | — | — | — | 7,34,654.16 | |
| — | 12.00 | — | — | ||
| Supply of CLS Signal post 3.6 Metre and ladder 3.5 M with bases ( 140mm dia, tubular) and platform confirming to IRS:S-6-81 and Drg. No 2011/M and for the ladder RDSO Drg. No. SA-23150 (adv) or latest. Inspection : Consignee | — | — | — | 2,24,525.04 | |
| — | 26.00 | — | — | ||
| Supply of colour light signal unit 2-Aspect complete without lamp holder, lamp, lense and signal transformer as per IRS-S-26/64 & RDSO Drg No , SA-23003 A/M(Adv) or latest spec. (i) With hand cuff lock 2 nos.Inspection : RITES | — | — | — | 5,04,097.88 | |
| — | 12.00 | — | — | ||
| Supply of colour light signal unit 3/4-Aspect complete without lamp holder, lamp, lense and signal transformer as per IRS:S-26/64 & RDSO Drg. No. SA-23002 A/M(Adv) or latest with hand cuff lock 2 No. Inspection : Consignee | — | — | — | 2,65,109.52 | |
| — | 12.00 | — | — | ||
| "Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg. No.NR/S&T/CON/4.3/97A) made of angle iron size 45mmx45mmx6mm along with outer frame made of angle iron size65mmx65mmx8mm, fitted with M.S. squares bars duly galvanized, descriptions strips to accommodate Plug- in-typerelays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts &nuts, washers, insulators, shoe, angle irons, flats, L- bolts, Catenary wires and cement concrete etc. will be supplied bythe contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection : Site Engineer" | — | — | — | 2,35,278 | |
| — | 12.00 | — | — | ||
| "Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/ 4.1 /97-A made of angle iron of size 45mmx45mm x 6mm along with outer frame made of angle iron of size65mmx65mm x 8mm duly fitted with Bakelite sheet of size6mm thick. This also includes fixing of ARA terminals & fusebases. supply of negative copper bus bar. Supply and fixing of hard wood of size70cmx 25cmx 4cm in the back forjamming of cables. Scaffolding /cable carrier made of angle iron of size 35mmX35mm X 6mm and flat of size 25mm X 5mm to be fabricated and supplied as per instructions of site Engineer. Separation between two flats will be250mm or lessas per site requirements. All materials required for scaffolding/ cable carrier to be supplied by the contractor. All the fixingmaterials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, cement, sand and concretes etc. will besupplied by the contractor. This includes cleaning, priming by red oxide, painting & writing of description etc. with ISImark paints of Asian /Burger//Nerolac or similar make. with IS specfication- 15489:2004. On site.inspection: Site Engineer" | — | — | — | 2,49,904.44 | |
| — | 600.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding/ cable carrier of angle iron of size 35mmx 35mm x 5mm andflat of size 25mmx3mm as per instructions of Engineer at site. The space between two flats shall be 25cm or less as per site requirements . All material required for scaffolding / cable carrier to be supplied by contractor. All fixing material like bolts nuts, washers, insulators, sand , cement & concrete etc, will be supplied by the contractor. This also includes insulating flat strips, cleaning, priming by red oxide, painting by ISI mark paint and writing of description of relays by ISI mark paints. Inspection- Consignee for supply portion | — | — | — | 3,06,978 | |
| — | 36.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C markers with complete fittings as per approved Drg. No. NR/S&T/CON/6.2/97or latest. All material required for the job such as MS sheet, MS angle. Nut and bolts, paint and painting materials will be supplied by the Contractor. The P and G markers shall be as perDrg. No. S 23456 (Adv) & SA 23477 (Adv) or latest respectively. Inspection : Consignee for supply portion. | — | — | — | 28,774.44 | |
| — | 60.00 | — | — | ||
| "Supply of Relays - Miniature, Plug-in Type, M to C, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B Contact, Code ABDGH/ABDFH Spec: BRS:931A; IRS S 34 ; IRS S 23 ;IRS S 60-78 , STR: SIQ 0420 Ver.1 or latest. Inspection : RDSO" | — | — | — | 2,65,890.6 | |
| — | 120.00 | — | — | ||
| Supply of Relays - Miniature, Plug-in Type, M to C, DC Neutral Line, Non AC Immunised Relay, Style QN1, 24 V DC, 8F-8B Contact, Code ABCDF/ABCDE Spec: BRS:930 ;IRS S 34 ; IRS S 23, STR: SIQ 0420 Ver.1or latest. Inspection : RDSO | — | — | — | 4,73,911.2 | |
| — | 65.00 | — | — | ||
| Supply of Relays- Miniature, Plug-in type, Tractive Armature, M to C, Universal AC lamp proving relay, Style QECX, 4F-4B Contact, for 110 V AC LED Signal Lamp Code ABDHK Spec: BRS:941A,STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amdt1, IRS S-23 & 34, STR: SIQ 0420 Ver.1 or latest. Inspection-RDSO | — | — | — | 3,59,208.2 | |
| — | 240.00 | — | — | ||
| Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material required will be supplied by contractor including indoor cables and wires of 1x1, 1x0.6, 3/.029, 16/0.2, 40x0.6, 40x1, 60x0.6, 60x1 dia.of copper conductor as per NR practice conforming to latest IRS S76/89 (Amd.3) or latest available specifications . This also includes soldering, dressing, bunching, lacing, fixing of relay bases etc. and provision of LED indication box of vitalrelays in relay room if required and provision of potential free contacts of all relays on tag block for data logger as perinstruction of site Engineer. Insepction : Site Incharge | — | — | — | 1,17,242.4 | |
| — | 6.00 | — | — | ||
| Design and preparation of Selection table, Panel Diagram, wiring diagrams and all other related documentation as per approved SIP and as given in Rly. Specification for PI/ RRI work (Circuits shall be designed by the contractor with the use of Q-series relays to suit 25 kv RE. which shall be supplied by the Rlys.) and obtaining approval of the engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings. (iv) Design through CAD (v) Drawings in A3 & plans in bigger size. (six sets). . Inspection : SSE/D&D | — | — | — | 22,455.42 | |
| — | 90.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pitin earth, 3 Mtrs. deepand fixing earth electrode pipe.Casting of cement concrete enclosuresas per drg. No. (NR/S&T/CON/6.4/97)or latest. The soil treatment shall bedone as per std.practice. The item includes provision of mild steel flat of size35mm x 6mm (as per IRSEM) and nutbolted connection of MS flat with earth electrode. The otherend of mild steel flat to be connected to block instrument,cable sheath of power equipment, signal base, apparatus case,CT rack / relay racks,other equipments as per the instruction of Engr. at site & IRSEM.Earth connection Signal & location boxes to be doneDrg.No. 19-D6 of IRSEM App II orlatest. Complete materials such as earth electrodes asper Drg. No. (NR/S&T/CON/6.3/97)or latest , cement,wiring material, nutbolt for connection &mild steel flat of size minimum 35mm x6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - Consignee for supply of earth electrode. | — | — | — | 3,04,014.6 | |
| — | 6.00 | — | — | ||
| "Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 and as per RDSO TAN letter No- RDSO- SIGEnB (GEN)/1/2020 dated 30.06.2025 or latest with latest amendments. Earthing kit consisting :- 1. Earthing electrode of 17.0 mm dia 3m long- 01 No. 2. Main equi-potential Earth Busbar (MEEB) (300mm x 25mm X 6mm minim.) - 01 No. 3. Sub equi-potential Earth Busbar (SEEB) (150mm X 25mm X 6mm minim.) 01No. 4. Earth Enhancing compound- 30-35 Kg (minimum) 5. Multi-strand single core PVC insulated copper cable 10 Sq. mm as per IS:694 used to connect individual equipment to SEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 6. Multi-strand single core PVC insulated copper cable 16 Sq. mm as per IS:694 used to connect SEEB to MEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 7. Multi- strand single core PVC insulated copper cable 16 Sq. mm as per IS:694 used to connect SPD to MEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 8. Multi- strand Single core PVC insulated copper cable 35 sq mm as per IS:694 (Duplicated) used to connect MEEB to main earth electrode Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 9. Copper tape or solid copper round conductor of 25x2 mm or 8 mm dia used to connect Main earth pit to other earth pit in case of loop earth as per site requirement. 10. Copper strip of size 200mm X 25mm X 6mm to be exothermically welded to earth electrode - 1 No. 11. Exothermic Weld Material & Mould as per site requirement. This includes:- Provision of earth connection from MEEB/SEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data logger etc. with PVC earth wire of Size 16/10 Sq mm. through copper lugs of suitable size. PVC earth wire for connection of MEEB/SEEB to equipment shall be supplied by railway, Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done for interconnection of two earth pits copper tape of size 25 X 2 Sq. mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Supply by RDSO approved Firm, Installation of MFE is to be done by OEM as per standard procedure and pre commissioning checklist to be submitted duly signed by OEM representative and Railway Representative. Inspection: RDSO for supply portion." | — | — | — | 1,55,237.22 | |
| — | 12.00 | — | — | ||
| Supply & installation of warning boards. This includes casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/stop dead boards/Goods Warning Board/ Passenger Warning Board as per drg. No. NR/S&T/CON/7.4/97 & provisions of SEM. Supply of SLB/BSLB/SB/calling on boards as per approved Drg. No.SA- 2373 or latest has also to be done by the contractor. (Inspection: Site Engineer) | — | — | — | 1,36,122.72 | |
| — | 300.00 | — | — | ||
| "Supply of electric fuse complete with fuse block (base) for Railway signalling non deteriorating type lowvoltage fuse assembly 2Amp/4Amp/16Amp. to suit Specn. No. IRS: S-78/2006 and fuse block made of PBT/Polycarbonate as per IRS:S-75/2006 (Rev.2 & Amd.2) and drg no. 23748 (IRS), Alt-4 or latest. Fuse block shall besuitable for round head type fuses. Inspection : RDSO for both Fuse and Fuse block" | — | — | — | 64,851 | |
| — | 6.00 | — | — | ||
| Fabrication & supply of domino type operating cum indication panel for way side station/LC Gate as per RDSO spec RDSO/SPN/186/2004, Ver.2 or latest (if applicable).This includes LEDs, acrylic sheet etc. One panel consist of 96 dominos as per approved panel diagram. Inspection : RDSO for supply portion. | — | — | — | 3,78,428.88 | |
| — | 6.00 | — | — | ||
| Installation and complete wiring of optg-cum indication panel for mid section LC Gates. Per Domino. Inspection : Site Engineer | — | — | — | 38,409.54 | |
| — | 6.00 | — | — | ||
| Supply, Installation & Commissioning of Emergency Sliding Boom complete with all accessories for L/B gate. Inspection- RITES | — | — | — | 16,47,553.98 | |
| — | 6.00 | — | — | ||
| "Supply, installation and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor. Inspection by - RDSO for supply portion." | — | — | — | 1,13,664.96 | |
| — | 6.00 | — | — | ||
| "Cleaning, scraping, painting and lettering of all newly installed and existing gears by the contractor for existing/new Level Crossing Gates.This includes supply of all painting materials and marking of all the ckt particulars near terminal on terminal board/in apparatus case/Jn. boxes and fuse nos, relay and equipments nomenclatures as per approved terminal chart and provisions of SEM. All paints (ISI marked) with IS specification No. IS:15489:2004 Asian /Burger/Nerolac or similar make. shall be approved by Railway Engr.and painting materials to be supplied by the contractor.Inspection : Site Incharge" | — | — | — | 1,36,525.74 | |
| — | 6.00 | — | — | ||
| "Supply, Installation, testing and commissioning of Electrically Operated lifting barrier assembly as per RDSO Spec. No. RDSO/SPN/208/2012 (version 2.0) or latest consisting of 2 nos. of electrically operated lifting barriers, 2pedestals, 8 band circuit controller with limit switches of Siemens, hand cranks, 2 electric motors, 110V AC, without centrifugal switch, 2 GI Boom in 4 sections of 8 feet each with 2 retroreflective stop boards, boom light boxes, MS counter weight, 2 nos. of boom support for resting boom etc. The item also consists of following items: a) Supply of motorized boom locking /unlocking assembly with electrical coil complete (1 no. each) b) Supply of level crossing gate control panel floor mounting type with switches and buttons sheet metal fabricated, (1 No) c) Supply of push button foroperating the gate with 2 No./NC contact, green colourclose & Amber-open, Siemens or Kaypee or similar make (1 no.)d) Supply of solid state electronic flasher 24V DC operated (1 no. each). e) Supply of dual tone warning bell with 20Whorn & 15W amplifier (2 no. each). Inspection : RDSO for sub part a to c & consignee for d & e." | — | — | — | 35,66,607.84 | |
| — | 6.00 | — | — | ||
| Supply of Electronic Timer relay, 24V DC, 60 sec as per RDSO Spec. IRS:S 61/2000 (Amend. No. 3) or latest. Inspection by- RDSO. | — | — | — | 20,038.74 | |
| — | 6.00 | — | — | ||
| Supply of Remote terminal unit (RTU) with 128 Digital & 16 Analog inputs with modem as per Specification No. IRS:S-99/2006 (Amdt- 3) or latest. Magnetic door lock coil to be supplied along with equipment. Inspection : RDSO for supply portion. | — | — | — | 9,56,306.04 | |
| — | 6.00 | — | — | ||
| Installation, Wiring, Testing, Validation and commissioning of Remote terminal unit with 128 Digital & 16 Analog inputs with modem as per Specification No. IRS:S- 99/2006 (Amdt-3) or latest. | — | — | — | 2,68,525.5 | |
| — | 6.00 | — | — | ||
| "Dismantling of lifting barrier/gate leaves complete set along with winch , wire rope, boom locking arrangements.All dismantled material to be transported and stacked in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Store or any other store of Northern Railway as per consignee. Note :- Before dismantling joint survey is to be done with the site Engr. and report to be submitted to the site Engr.(1 Job= 1 LC)." | — | — | — | 19,950.96 | |
| — | 160.00 | — | — | ||
| Supply and installation of Electronic Cable Routemarkers (with RFID) as per TEC Specification no.TEC/GR/TX/TIE07/02/Mar-14 or latest, of suitablefrequency and color for Telecommunication cables asper the TEC Specifications, to be provided at thespacing of 200 metres in the trench and at places /corners where the route of cable changes including atboth ends of Level crossings Road crossings. TheElectronic route marker shall also be provided at theall joints also. It includes the programming ofMarkers as per Instructions of Engineer in charge andpreparation & submission of the list of IDs of allMarkers installed. The Marker shall be ofSpecifications to work for minimum 5 feet distance(depth). The Markers and the Marker Locator unit(Locater covered separately) are to be inspected &supplied together of same make and compatible model. (Inspection: Supply- RITES, Installation- SiteIncharge) | — | — | — | 4,65,126.4 | |
| — | 1.00 | — | — | ||
| Supply and installation of Electronic Cable Routemarkers (with RFID) as per TEC Specification no.TEC/GR/TX/TIE07/02/Mar-14 or latest, of suitablefrequency and color for Telecommunication cables asper the TEC Specifications, to be provided at thespacing of 200 metres in the trench and at places /corners where the route of cable changes including atboth ends of Level crossings Road crossings. TheElectronic route marker shall also be provided at theall joints also. It includes the programming ofMarkers as per Instructions of Engineer in charge andpreparation & submission of the list of IDs of allMarkers installed. The Marker shall be ofSpecifications to work for minimum 5 feet distance(depth). The Markers and the Marker Locator unit(Locater covered separately) are to be inspected &supplied together of same make and compatible model. (Inspection: Supply- RITES, Installation- SiteIncharge) | — | — | — | 4,97,618.35 | |
| — | 6.00 | — | — | ||
| Supply of Earth Leakage Detector (ELD) (8 Channel) as per RDSO Spec No. RDSO/SPN/256/2025 version-2.0 or latest. Inspection - RDSO | — | — | — | 4,92,802.26 | |
| — | 6.00 | — | — | ||
| Installation, testing & commissioning of Earth Leakage Detector (ELD) - 8 channels as per Specification No. RDSO/SPN/256/2025 version-2.0 or latest. Insepction : Site Incharge | — | — | — | 31,383.66 | |
| — | 6.00 | — | — | ||
| "Supply, wiring and fixing of Description board made of Ply 6 mm thick with white sunmica glued over its surface and 1"" x 1"" wooden baton fitted all around on the rear and having alluminium angle size of 25.4mm x 25.4mm x 3.15mm on all four sides as per instruction of Engineer at site. All the material to be supplied by contractor.Inspection- Consignee for supply portion." | — | — | — | 15,161.16 | |
| — | 12.00 | — | — | ||
| Supply fixing and wiring of fuse auto changeover system (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC / 110VDC / 110VAC (type-a & type-b) which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. .Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor. Inspection by RDSO | — | — | — | 4,77,705 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of UL/FM/VDS/LPCB approved Microprocessor based networkable analogue addressable and modular type of Fire alarm control panel with display, in built charging facilities and provision of GSM module suitable to send SMS to configured mobile no. as per RDSO specification no. RDSO/SPN/217 /2021 ver 3.0 or latest. The Control panel shall be the central processing unit of the system, receiving and analyzing signals from probe type bimetallic heat detectors, UV&IR flame detectors, heat and smoke multi sensors, LHS/LHSD interface and manual call points, providing audible and visual information to the user. The panel shall have provision of connectivity of TCPIP suitable for programming and remote monitoring. The panel provision for interfacing with existing data logger, optional remote printer As per RDSO specification no. RDSO /SPN/217/ 2021 ver 3.0 or latest . Material Inspection by RDSO. | — | — | — | 6,41,122.8 | |
| — | 6.00 | — | — | ||
| Supply, installation, commissioning of UL listed glass break manual call point as per RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO | — | — | — | 33,170.7 | |
| — | 60.00 | — | — | ||
| "Supply of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/ SPN/217/ 2021 ver 2.0 or latest. Inspection: RDSO Inspection " | — | — | — | 1,76,560.2 | |
| — | 6.00 | — | — | ||
| Supply, installation, commissioning of RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO | — | — | — | 65,600.28 | |
| — | — | — | alarm | ||
| — | — | — | unit | ||
| — | — | — | as | ||
| — | 600.00 | — | — | ||
| "Supply, installation, commissioning of circuit integrity cable 2 core 1.5 Sq.mm as per RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO " | — | — | — | 1,66,116 | |
| — | 600.00 | — | — | ||
| "Supply, installation, commissioning of analogue type Linear Heat Sensing (LHS) cable which is self restorable after the fire event as long as its temperature does not exceed specified resettable temperature limit of 120 degree celsius it shall have an activation temperture of 70 degree celsius as per RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO " | — | — | — | 10,21,308 | |
| — | 6.00 | — | — | ||
| "Supply, installation, commissioning of Linear Heat Sensing interface module as per RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO " | — | — | — | 8,53,399.74 | |
| — | 12.00 | — | — | ||
| "Supply of CO2 Fire extinguisher 4.5 kg capacity confirming to IS 2878: 2004 or latest with ISI mark provided with all fittings and accessories as per RDSO/SPN/217/2025 ver 3.1 or latest. Inspection- Consignee" | — | — | — | 1,20,411.6 | |
| — | 24.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C markers with complete fittings as per approved Drg. No. NR/S&T/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) & SA 23477(Adv) respectively. Inspection: Site Engineer | — | — | — | 19,182.96 | |
| — | 12.00 | — | — | ||
| Supply & Installation of Thermoshrink jointing kit for 6-Quad cable and PIJF cable for Derivation/ Termination joints at LC Gates/Pump House/different locations as decided by the site Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 & 2 or latest. This includes all materials required for joints.Inspection : RDSO for supply and Site Engineer for execution. | — | — | — | 1,02,564.6 | |
| — | 2.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100V/500V, Motwani, Philips or equivalent make.Inspection by consignee | — | — | — | 9,367.68 | |
| — | 2.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC upto 50Amp(AC/DC), 600V(AC/DC) and 0.1 ohms40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Inspection :Consignee | — | — | — | 17,204.3 | |
| — | 2.00 | — | — | ||
| — | — | — | 81,455.4 | ||
| — | : - Supply by | of Earth Tester or similar Offer Consignee. | per specification: Model: CET- 03 | ||
| — | 1.00 | — | — | ||
| — | — | — | 3,31,526.02 | ||
| — | : - Supply better. | of Cable Fault or similar, Model Inspection: Site Incharge | specification Make: (1155-5001) | ||
| — | 1.00 | — | — | ||
| "Supply of electronic Cable Route Tracer as per latest TEC spec. no G/TIE-01/02.OCT 99 (With amendment no 1 dtd 29.09.2000 & 03.06.2004) or latest amendment. Inspection : Rites " | — | — | — | 3,84,208.11 | |
| — | 12.00 | — | — | ||
| Supply of 4 wire leasedline External modem for networking of RTU with Dataloggers per RDSOspecn. No. IRS- S-99/2006, Amnd-3 orlatest. (Inspection by Consignee) | — | — | — | 2,95,210.8 | |
| — | 600.00 | — | — | ||
| Preparation of SWR i. Translation of SWR from English to Hindi. : Inspection by Consignee | — | — | — | 12,594 | |
| — | 600.00 | — | — | ||
| Typing and Printing One master Copy SET in Hindi. Inspection by Consignee | — | — | — | 13,740 | |
| — | 600.00 | — | — | ||
| Two Photocopies of Hindi Master Copy Set. Inspection by Consignee | — | — | — | 888 | |
| — | 12.00 | — | — | ||
| Spiral Binding of master of SWR & 02 set of photocopies as above including plastic cover. Inspection by Consignee | — | — | — | 649.32 | |
| — | 2.00 | — | — | ||
| Supply of cable indoor copper conductor Multi core plain annealed high conductivity PVC insulated unarmoured but PVC sheathed size 60x1mm as per spec. No.IRS- S/76/89 with latest amendment. Inspection by RDSO. | — | — | — | 9,11,860.86 | |
| — | 2.00 | — | — | ||
| Supply of Flexible , PVC sheathed, PVC insulated Copper wire 16/0.20 mm (wiring materials) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest. Inspection :RDSO | — | — | — | 18,405.96 | |
| — | 2.00 | — | — | ||
| Supply of power wires 1x6 sq.mm. (Red & Black ) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest (in 100 Mtrs coil). Inspection RDSO | — | — | — | 1,14,576.38 | |
| — | 2.00 | — | — | ||
| Supply of power wires 1x16 sq.mm. (Red & Black ) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest (in 100 Mtrs coil). Inspection RDSO | — | — | — | 2,90,285.82 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
TenderDocumentPROJECT_DLI_SNT_26_06_3.pdf Tender Document
ATTACHMENT
ListOfLCs_2.pdf
ATTACHMENT
TenderDocumentPROJECT_DLI_SNT_26_06_3.pdf
ATTACHMENT
TenderDocumentPROJECT_DLI_SNT_26_06_.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .