Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NO 45 2ND FLOOR RANGANATHA LAYOUT NEAR GURUKUL HIGH SCHOOL MAHADEVAPURA BANGALORE KARNATAKA 560048 | BENGALURU URBAN | KARNATAKA | 560048 | Admitted-Finance |
| 4 | Admitted-Finance C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
Tender Value
₹95.6 L
EMD Value
₹1.9 L
Closing Date
5 Jan 2023, 3:00 pmClosed
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras CHENNAI-600036
Annual Maintenance contract for attending complaints and minor project works in substation and cables in IIT Madras campus for the year 2023-2024
2022_IITM_138383_1
02/2023-24/ELDB
Open Tender
Electrical Works
Item Rate
365 days
IIT MADRAS CHENNAI
All required documents as specified in the tender
2 documents required · 2 mandatory
₹0
₹1.9 L
Google Meet
11 Jan 2023
15 Dec 2022
6 Jan 2023
16 Dec 2022
5 Jan 2023
22 Dec 2022
16 Dec 2022 - 20 Dec 2022
21 Dec 2022
Amount
Attending day to day maintenance of HT/ LT equipments, break down work, fuse of calls, emergency faults, major break down inside the entire campus on round the clock service on shift duty work with the following designated staff. (Shift Duty: 3 shifts/day) 1 no Electrical Supervisor with valid C License and 1 No Electrician with valid B license and 1 No helper in each shift and total three shifts in a day. The Electrical Supervisor , Electrician and helper should have minimum three years experience in maintenance of Substations up to 33kV Supply System in shift duty.
In Addition to the above one sweeper has to be posted in General shift to clean the main substation and the other unmanned substations as instruted by the Engineer in charge .(Relevant document proofs should be submitted and got approved from the Engineer Incharge before engaging the above staff. ( Data Enclosed)
Supplying and Terminating the ends of the following 11kV XLPE sheathed alu stranded conductor armored under ground cable with suitable lug / Ferrules socket and using necessary jointing materials with RPG make heat Shrinkable Joint Kit.
3C x 120 Sq.mm
3C x 240 Sq.mm
3C x 300 Sq.mm
Supplying and making Straight Through Joint for the following 11kV XLPE sheathed alu stranded conductor armored under ground cable with suitable lugs/Ferrules socket and using necessary jointing materials with RPG make heat Shrinkable Joint Kit.
3C x 120 Sq.mm 10.6.2
3C x 240 Sq.mm 10.6.3
3C x 300 Sq.mm 10.6.4
Supplying and replacing of following ratings of the HRC DIN Type Fuse links in the distribution pillar-boxes. The rate should be inclusive of making holes on the existing copper bus bars and removal of terminations for the existing cable if necessary when attending fault.
63 A DMC HRC Fuse Link
125A DMC HRC Fuse Link
250A DMC HRC Fuse Link
400A DMC HRC Fuse Link
Supplying and replacing of following ratings of the HRC DMC Fuse bases in the distribution pillar-boxes. The rate should be inclusive of making holes on the existing copper bus bars and removal of terminations for the existing cable if necessary when attending fault.
63A DMC HRC Fuse base
125A DMC HRC Fuse base
250A DMC HRC Fuse base
400A DMC HRC Fuse base
Removing the following sizes LT UG cable of size up to 3.5c x400 sq.mm from the trench of 75cm depth including earth work excavation in all soils and sub soils for identifying the faults and relaying the same cable / other cable in the trench, sand filling and brick cover protection of the cable using existing burnt bricks/ removed RCC troughs etc and back filling. consolidated etc as required.
Supplying& Laying of following sizes PVC XLPE insulated alu. Conductor armored 11kV HTUG cable in a 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 100cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification.cable identification on both side with aluminium cable tags.
3C x 120 sqmm XLPE insulated armoured aluminium cable.
3C x 240 sqmm XLPE insulated armoured aluminium cable.
Supplying& Laying of following sizes PVC XLPE insulated alu. Conductor armored 1100V LTUG cable in a 50 mm to 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 75cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification.cable identification on both side with aluminium cable tags.
4c x 10 sq.mm XLPE insulated armoured aluminium cable.
3.5c x 35 sq.mm XLPE insulated armoured aluminium cable.
3.5c x 70sqmm XLPE insulated armoured aluminium cable.
3.5c x 150 sq.mm XLPE insulated armoured aluminium cable
3.5c x 240 sq.mm XLPE insulated armoured aluminium cable.
3.5c x 400 sq.mm XLPE insulated armoured aluminium cable
12 core x 2.5 sqmm copper armoured control cable
Supplying and making end termination for following sizes alu. Conductor LT UG cable using suitable compression gland with required copper ferulles / socket and other jointing materials
4c x 10 sq.mm
3.5c x 35 sq.mm
3.5c x 70sqmm
3.5c x 150 sq.mm
3.5c x 240 sq.mm
3.5c x 400 sq.mm
Supplying and making straight thro cable joint for following sizes aluminium or copper Conductor LT UG cable using Heat Shrinkable /cast resin materials ( M-Seal-3M or RPG) with required copper ferulles / socket and other jointing materials.
4 core 6 or 10 sq.mm ( cast resin)
3.5 core 35 sq.mm ( cast resin)
3.5 core 50 sq.mm ( cast resin)
3.5 core 70 sq.mm ( cast resin)
3.5 core 150 sq.mm ( Heat Shrinkable)
3.5 core 240 sq.mm ( Heat Shrinkable)
3.5 core 300 sq.mm ( Heat Shrinkable)
3.5 core 400 sq.mm ( Heat Shrinkable)
Labour charges for making temporary connections to pump motors / streetlights / Residential buildings in case of existing cable failure by laying copper / aluminium wires from the nearest source of supply. (Necessary wires has to be supplied by the contractors and removed after making permanent connections)
Supplying and fixing of the following MCCB's in the existing MV panel with necessary incoming and outgoing connections without enclosure and including extended bars /wires if required/ terminal spreaders.
200 A FP MCCB,36 KA Adjustable thermomagnetic release
250 A FP MCCB, 36 KA with Adjustable Thermal and Magnetic release
400A TP MCCB,35 KA with Adjustable thermomagnetic release
630A FP MCCB,50 KA with Adjustable thermomagnetic release
800A FP MCCB,65 KA with Adjustable Thermal and Magnetic release / Ajustable overload /Adjustable Short Circuit
250A FP MCCB,50 KA Adjustable Thermal and Magnetic release with enclosure
TAP OFF Box with 63A TPN 35kA MCCB
TAP OFF Box with 125A TPN 35kA MCCB
TAP OFF Box with 200A TPN 35kA MCCB
Earthing with copper earth plate 600x600x3mmthick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc with charcoal/coke and salt as required.
Earthing with GI earth plate 600x600x6 mmthick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc with charcoal/coke and salt as required.
SITC of Chemical Earthing -copper bonded solid rod 25mm dia earth electrode with ,3 metre length with 50Kg high conductive earthing compound including all acessories and providing HDPE round earth pit chamber and cover (300MMx350MM) with cover plate having locking arrangement as instructed by engineer incharge.(make: cikit,infinite, Ashlok).
Concrete earth chamber with cover plate inner size 350X350X350 mm including excavation and all masonary works. The work should be inclusive of white washing the masonary pedastals , paint marking for the earth values, date of testing done , due date for the next test and pit number on the enclosures and also inside the earth pit.
Supplying and laying of following size earth flats at 0.50 mt below the earth including soldering/welding as required
Single run of 16 sqmm multistranted copper wire in a suitable PVC pipe and clamps
25 x 5mm copper flat
25 x 5mm GI flat
50 x 6 mm GI Flat
Supplying and replacing of 110V AC/DC indication LED lamps as instructed by the Engineer incharge.
Supplying and replacing of 220V AC indication LED lamps as instructed by the Engineer incharge.
Testing of earth electrodes using necessary testing equipment and improve the earth by excavating the soil and sub soil and refilling the same with alternate layer of charcoal/coke and salt if required. The values are to be entered in a seperate register and submitted to the Engineer incharge . The work should be inclusive of replacement of bolts and nuts, white washing the masonary pedastals , paint marking the earth values, date of testing done , due date for the next test and pit number on the enclosures and also inside the earth pit.
Removing the existing LT panel with bus coupler from the foundation by removing the existing LT UG cable feeders of size varying from 70 to 400 sqmm (App. 12 terminations / Panel) and transport the LT panel to the other substation / Godown inside the premises.
Erection, testing and commissioning of the LT panel with Bus coupler on the existing trench with necessary channels. L angles, civil works, chipping and grouting etc. The rate should be inclusive of earthwork for removing the existing LTUG cable with suitable glands and sockets ( app 12 terminations/ panel with cable size varies from 70 to 400 sqmm) the tenderer should inspect the site before quoting.
Supplying and replacing of silica Gel for the Power/ Distribution transformer breathers
Supplying and replacing of mineral oil suitable Power/ Distribution transformer as per IS 335/1993
Painting of MV Panel Board by scrapping the Board using necessary scrapping material and painted with two coats of siemens grey colour enamel paint .Numbering of each timer box& in/out going cable identification for individual feeders on the door ( approximately 200 letters @ 1 inch Size per Panel Board ) has to be done as instructed by the Engineer Incharge. The rate should be inclusive of white washing the pedastal.
S. N. ELECTRIC & MAINTENANCE PRIVATE LIMITED
Gnosi Tech Services
Delhi Electrical Construction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .