Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹21.5 L+₹26,196 (1.23%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹45,600
Closing Date
30 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
GE Faridkot-151203 Punjab 01639-264982
Provn of 01x Guard room with toilet alongwith hard standing at A Arty Bde and certain revenue/minor works under AGE B/R (M) at Faridkot Mil Stn
2020_MES_372307_1
GE FRD-51/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹45,600
Yes
9 Nov 2020
26 Aug 2020
2 Oct 2020
26 Aug 2020
30 Sept 2020
16 Sept 2020
60 days
Amount
Surface excavation in soft/loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed by Engr-In-Charge.
Excavation in trenches in soft loose soil not exceeding 1.5m deep and 1.5m wide, for foundation etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed by Engr-In-Charge.
M & L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, sub base & mass concrete complete all as specified and directed by Engr-In-Charge.
M&L for providing Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in foundation including rafts, footings, foundations beams; plinth beams, bases for column etc; basement slabls, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in column, pillars, piers, posts and sturtscomplete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in lintelts upto 1.5 mtr clear span, siesmic band and similar works including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in slab supported on walls, beams, columns,landings,balconies, canopies,deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding. 25cm thick each complete all as specified and directed by Engr-In-Charge.
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr-In-Charge.
M&L for broken brick hard core of gauge not exceeding 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge
M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M&L for use and waste of form work to sides of columns for fair finished surfaces complete all as specified and directed by Engr-In-Charge.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs not exceeding 200mm thick horizontal or sloping complete all as specified and directed by Engr-In-Charge.
Use and waste formwork to sides and soffits lintels with chajja over 1.5m clear span complete all as specified and directed by Engr-In-Charge.
M&L for Use and waste of form work to edges of concrete flats, treads, window, Cills, etc exceeding 10cm but not exceeding 20cm wide complete all as specified and directed by Engr-In-Charge.
M&L for TMT bars 10mm dia and over cut to length bent to shape as required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr-In-Charge.
All as per item No 16 but 6 to 8mm dia as in stirrups complete all as specified and directed by Engr-In-Charge.
M&L for brick work with fly ash bricks of old size straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engr-In-Charge.
M & L for cement Concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in coping, bed block of hold fast and splash stone complete all as specified and directed by Engr-In-Charge.
Material and labour for providing 50 mm thick cement concrete (1:3:6) type C1 using 20mm graded aggregate as in plinth protection, foot path, drains surfaces even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 10mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces mixed with WPC @ 3 % by weight of cement and surface finished even and smooth without using extra cement complete all as specified (WPC willl be measured & paid for separately) complete all as specified and directed by Engr-In-Charge.
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engr-In-Charge.
M & L 20-25mm thick Kota stone slab over 15mm thick screed bed of CM (1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of slab in including rubbing and polishing complete all as specified and directed by Engineer in Charge.
All as per Srl item No 25 but but as in riser of step / skirting / dado and pillar complete all as specified and directed by Engr-In-Charge.
Material and labour for 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor etc laid down in panels and finished even and smooth with using extra cement complete all as specified and directed by Engr-In-Charge.
S&F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint, hinges, hold fasts / lugs etc complete all as specified and directed by Engr-In-Charge.
Framed work such as grills, gratings,etc., with ends of bars shoulderd and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe290, Gde-E-165 complete all as specified and directed by Engr-In-Charge.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as per SSR Part-II complete all as specified and directed by Engr-In-Charge. (Note : The material shall be of make Sintex/ Rajshri duly fabricated by thier authorised fabricator)
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stick inside with solvent cement for stile and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the style and rail with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specifications & drawings as mentioned on Page 146 of SSR Part-II. (Note : The material shall be of make Rajshri/Sintex duly fabricated by their authorised fabricator.)
S&F 35mm thick factory made 2nd class hard wood plain framed panel shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering both faces. The size of rail and style shall be as per IS:1003 (Part-I), klin seasoned and chemically presuure treated complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick second class Hard Wood glazed and skeleton shutters confirming to IS-1003 (Pt-1) offer rebated and prepared to receive glass/gauze etc (without sash bars) edges of forming plain chamfered or rounded fixed and mitered beads for securing glass etc size of members of shutter shall be as per SSR Pt –I section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified & directed by Engineer-in-Charge.
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified & directed by Engineer-in-Charge.
Supply only 100mm butt hinges medium weight, cold each rolled, mild steel complete all as specified and directed by Engineer-in-Charge.
S&F factory made mild steel ventilators box type with sash bars dovetailed or welded ready for wire mesh/glass pan including one shop coat of red oxide primer, complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long mild steel ordinary rat tail rod pattern springs (Helical door spring) including roller and roller plate fixed or welded to steel frame complete all as specified & directed by Engineer-in-charge.
S&F aluminium anodized tower bolts 150 mm long of extruded section fixed to doors with screws complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodized cast type handle 125 mm size complete all as specified and directed by Engr-In-Charge.
S&F 250 mm long aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- charge.
S&F Mild Steel tower bolts 200 mm long stove enamelled black fixed to doors with screws complete all as specified and directed by Engineer-in-Charge.
S&F 125mm size mild steel bow handle oval type stove enamelled black complete all as specified & directed by Engineer-in-Charge.
S&F MS fan hook made out of 16mm dia round MS bars at approx design complete all as specified & directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.45mm nominal dia of wire average width of aperture not more than 1.25mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick plain sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick figured glass pin head type and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
M & L for 25 mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregates finished rough to receive glazed tiles complete all as specified and directed by Engr-In-Charge.
S & F Non skid ceramic coloured tiles light colour (as approved) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
S&F Glazed ceramic coloured tiles 250mmx300mmx7 mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry over & including 10mm thick rendering in cement mortar 1:3 and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
S&F sand casted cast iron soil, waste and vent pipe 100mm bore in any length without ear with cement joints laid in trenches or in floors complete all as specified and directed by Engr-In-Charge.
All as per Serial item no 51 here-in-before but 75 mm bore complete all as specified and directed by Engr-In-Charge.
All as per Serial item 51 here-in-before but 50 mm bore pipe fixed to walls complete all as specified and directed by Engr-In-Charge.
S&F cast iron cowl 50mm size complete all as specified and directed by Engineer in Charge.
S&F Cast iron bend 100mm bore any radius complete all as specified and directed by Engr-In-Charge.
All as per Serial item No 55 here-in-before but 75 mm bore complete all as specified and directed by Engr-In-Charge.
S&F CI branch piece single (equal or unequal) spigot or socket type 100mm bore complete all as specified and directed by Engr-In-Charge.
M & L for cast iron nahani/ floor trap of 75mm dia of outlet with grating jointing to waste pipe in run lead complete all as specified and directed by Engr-In-Charge.
S&F ball brass valve high pressure, with polythene float and fly nut complete screwed for iron or brass ferrule of 20mm bore complete all as specified and directed by Engr-In-Charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe and dismantling of old water tank complete all as specified and directed by Engineer in Charge.
S&F vitreous china ware glazed wash hand basin white, flat back of size 550mm x 400mm including CI brackets, CP brass waste coupling with rubber washer and galvanized mild steel waste pipe 32mm bore complete all as specified and directed by Engr-In-Charge.
S&F Salt-glazed stoneware gully traps, size 150mm x 150mm, square or round mouthed, type 'P' complete all as specified and directed by Engineer-in-Charge.
M&L for Cutting holes into through brick walls built in cement mortar and making good in cement mortar 1:3 or PCC 1:2:4 type B1 as required superficial area not exceeding 150 Sqcm complete all as specified and directed by Engineer-in- charge.
S&F GI tubing medium grade 15mm bore with all fittings and fixed to wall/ceiling and laid in floors complete all as specified and directed by Engr-In-Charge.
S&F GI tubing medium grade 20mm bore with all fitting and fixed to wall/ceiling and laid in floor complete all as specified and directed by Engr-In-Charge.
S&F bib tap CP brass with crutch or butter fly handle screwed down screwed for 15mm bore pipe & fixed complete all as specified and directed by Engr-In-Charge.
S&F Cast copper alloy stop valve/angle ball screwed down for high pressure with crutch or butter fly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed by Engr-In-Charge.
S&F CP pillar tap cast copper alloy of 15 mm size with capstan heads screw down for high pressure fixed to iron pipe complete all as specified and directed by Engr-In-Charge.
S&F PVC connection 15mm dia 45 cm long with brass nut and washer both side complete all as specified and directed by Engr-In-Charge.
S&F PTMT shelf fixed with and including Chromium plated brass screw and plastic cleat complete all as specified and directed by Engr-In-Charge.
S&F PTMT towel rail 20mm dia, 450 mm long including brass screw and plastic cleat (Minimum weight 170 gms) complete all as specified and directed by Engr-In-Charge.
S&F 100mm dia grating of PTMT complete all as specified and directed by Engr-In-Charge.
S&F Vitreous china bowl urinal flat back, size of 465mm x 355mm x 265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete with flush pipe and half turn valve 15mm bore all as specified and directed by Engineer - in - Charge.
S & F Vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing and provision of PVC 10 ltrs symphonic action type flushing cistern including flush pipe of PVC and connection to WC pan complete all as specified and directed by Engr-In-Charge. .
Supply and fix PVC low level flushing cistern white 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and 15mm bore PVC connection complete all as specified and directed by Engineer-in-Charge.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated,fancy type screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-In-Charge.
S&F Reinforced concrete pipes class NP-2 / NP-3 laid, jointed and tested complete with collar of size 150mm (internal dia) all as specified and directed by Engineer in Charge.
Extra for forming fair finish to drain or channel exc 20cm PCC 1:2:4 type B1 using 20mm graded stone aggregate as PCC benching for manholes, bands, coping, bed plates including slightly rounded or chamfered angles including necessary form work complete all as specified and directed by Engr-In-Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid & tested for 150mm bore of pipes NP-2/NP-3 complete all as specified and direced by Engineer in Charge.
M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in benching for manholes cover, bands, coping, bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed by Engineer in Charge
M&L Precast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in coping of manholes, benching for manholes, bands, coping, bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed by Engineer in Charge
Cutting into existing manholes for connecting new drains, making good to pipe and ren-dering, cutting out existing benching for and forming branch channel (1/2) round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming bench-ing as required (Internal Dia of pipe in 150mm) complete all as specified and directed by Engr-In-Charge.
M & L 75 mm thick cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engr-In-Charge.
M&L machine pressed precast concrete interlocking coloured paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling under floors in layers n.exc 25 mm thick complete all as specified and directed by Engr-In-Charge.
M&L Painting to plastered /concrete surface with two coats of Road marking paint white or golden yellow including priming coat complete all as specified and directed by Engineer-in-Charge.
M&L for (Factory casted , rubber moulded) Pre-cast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in kerb stone (of size 300 x 100 x 200mm or as per site requirement) with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4 including necessary form work and excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 Mtr and depositing where directed complete all as specified and directed by Engineer in Charge.
M&L for Roof treatment to RCC roof as specified below as directed :- (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brusing or high speed water jet, surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, dmanged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Apllying one coat of prime seal / Epoxy Primer/ Shaili Urethane BTD white diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg/Sqm (0.20 Kg BTD + 0.20 Kg water) (d) Laying polyster reinforced fiber net / 50gsm Geotextile mesh upto 300mm on walls. (e) Applying three coat of Hydro Shield PUD micro fibre reinforced UP resistent polyurethane (solid content 68%) / Damp proof ultra UV stable fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers (Solid content 55%) / Smart care PU magnum elastomeric water proofing coating based on hydrophobic plyuethane (Solid content 85%) / Single component elastomeric Liquid Membrane Shali Urethane BTD white/ coloured (Elongation 400% + 50, Solid contents > 80% & Specific gravity @ 30 OC 1.5 + 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush / roller upto 300mm on walls. Make : Dr Fixit/ Asian/ STP Limited Note : The complete treatment to be carried out through authorised applicator of water proofing manufacturers.
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified & directed by Engr-In-Charge. (Payment for providing grooves shall be made separately).
M & L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
M & L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer in Charge.
M & L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer in Charge.
M&L preparation of newly plastered surfaces of walls etc., and applying two coats of oil bound distemper including one coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or unplastered wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engr-In-Charge.
Preparation of new wooden or wood based primer surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-In-Charge.
S&F gypsum board 12mm thick in ceiling fixed with screw as per manufacturer's instructions, plain / coloured fixed on steel snap grid (Powder coated bottom side) with 'T' and 'L' (25mm x 30mm x 1mm thick) size of grid 600mm x 600mm placed in ceiling 'L' section fixed with wall using PVC rawl plugs and steel screws @ 600mm centre to centre and suspended / provided 5.0mm dia galvanised bars @ 1.00 Sqm hanging arrangements and level including adjustable clips all as specified and directed. in clause 10.38 of MES Sechudle Part-I complete all as specified and directed by Engineer in Charge. (Note : If any minor electrical fittings and fixture disturbed there in will be match and fixed as existing)
S&F PVC hollow wall lining interlocking type of 7mm thick plain/coloured fitted into the wall with PVC rawal plugs and steel screws including fillets to joints as per manufacturers instruction etc.complete all as specified and directed by Engineer-in-Charge. Note:- If any minor electric fittings and fixtures disturbed there will be match and fixed as existing.
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed by Engineer-in-Charge.
S &F Vitrified ceramic coloured (Coloured & shade as approved) tiles (square/rectangular) polished area of each tile of size 600x600x10mm as in floors etc set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
S &F Vitrified ceramic coloured (Coloured & shade as approved) tiles (square/rectangular) polished area of each tile of size 600x600x10mm as in vertical surfaces such as skirting / dado etc set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
Taking down & Supply, laying, jointing and testing and commissioning of cross sectional area 10 sqmm, 2 core XLPE insulated screened PVC bedded galvanised steel strip wire, armoured electric cable heavy duty multi stranded aluminium conductor PVC sheathed LT cable 1100 volts grade conforming to IS-1554 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supply and fix GI pipe 40mm bore light grade with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, nuts, bolts and washers complete all as specified and directred by Engineer-in-Charge.
M&L for MS clamp fabricated from MS flat of size 40mmx6mm including nuts, bolts, washers, bending cold or hot drilling holes for bolts in any shape or size for holding GI pipe with pole and wall complete all as specified and directed by Engineer in Charge.
Cutting the existing CI pipes in trenches 100/80mm dia from making connection to proposed 25mm dia DI pipe including provision of CI/GI Tee of size 80x80x25mm collar lead joints etc as required at site complete all as specified and directed by Engr-In-Charge.
S&F GI tubing medium grade 25mm bore with all fittings and fixed to wall/ceiling and laid in floors/trenches complete all as specified and directed by Engr-In-Charge.
S&f Gun Metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 25mm dia of pipe complete all as specified and directed by Engr-In-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover sheet of required colour fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for One light point/call bell point/fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
All as per Srl item No. 113 here-in-before but Switch socket combination (multi purpose) 5 Pin 5 Amps 230 volts point to be controlled by one switch and wiring with 1.5Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board.
All as per Srl item No. 113 here-in-before but on same board.
All as per Srl item No. 113 here-in-before Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm PVC unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed by Engineer in Charge.
S&F switch Piano type single pole one way 5 Amp, 230 VAC supply complete all as specified and directed by Engineer in Charge.
S&F socket two in one, 5 Pin 5 Amps 230 VAC supply, complete all as specified and directed by Engineer in Charge.
S&F switch piano flush type single pole one way 15 Amps, 230 volts on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.(Note:-Sheet top cover included in point wiring)
S&F socket piano flush type 6 pin 16 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F 5 speed electonic regulator suitable for ceiling fan 1200mm/ 1400mm sweep,socket, electronic type 230 Volt complete all as specified and directed by Engineer-in-Charge.
S&F PVC /Polycarbonate Lamp holder with back plate suitable for batten fittings and including LED Lamp 9 Watt complete all as specified and as directed by Engineer-in-Charge.
S&F complete set of tube light fitting, 1x18/20 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, decorative bipin holder, LED tube internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge. Make: Bajaj cat No.BCLSB 18W LED or Havells/Phillips
S&F 1X10 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed by Engineer-in-Charge.
S&F compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps 1x 12 watt fitting including LED lamp 12 watt complete all as specified.
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultrathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 3 star rating including fixed along walls including grouting fastening & fixing nuts/bolts of sitable size (04 Nos) and connecting up inlet/ outlet with cold water and hot water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed by the Engr-in-charge.
Supply, install, testing and commissioning of evaporative air cooler in steel body (desert cooler) made out of hot dip galvanised steel plain sheet thickness 1mm body and 2mm thick removable sides and back panels, single phase 230 volts of exhaust fan size 450mm sweep with submersible pump of suitable size / capacity (ISI marked) (maximum power consumption 250 watts), PVC grills, conecting copper cable with three pin length not less than 2.0 m, PVC connecting pipe of suitable length, BEE approved, having normal air flow 4000 cum per hour conforming to trade pattern including arrangement for fixing 15mm bore float valve, stop valve & PVC connection, leakage proof joints complete all as specified and directred by Engineer-in-Charge.
S&F ceiling fan (white colour) 1200mm sweep, 380 RPM, air delivery 220 cmm, single phase 220 volts with electronic (socket) type fan regulator, down rod & other accessories, three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose/connector to ceiling fan complete all as specified and directed by the engr-in-charge .
S&F MCB distribution board double door of sheet metal single pole and neutral 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F MCB ,SPN 240 volt 40 Amp breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge. Make-Havells/Siemens/Legrand /Indo Asian.
S&F MCB single Pole 240 Volts 6 to 32 Amp breaking capacity 10 KA complete all as specified and directed by Engineer in Charge. Make-Havells/Siemens/Legrand /Indo Asian.
Supply, fixing and testing LED street light fitting of 25 Watt including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/ Havells/Philips or equivelant Note :- (a) Bidder shall submit rest report of LED street light fitting from accredied test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M & L Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C2 using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion complete all as specified and directed by Engineer in Charge. Note : The unit rate including earthing lead & protection pipe upto 7.5 meter from top to earth plate.
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .