Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC L1 and Accepted | |
| 2 | L2₹2.2 L+₹11,152 (5.30%)Rejected-Finance 9 9 SITALATALA 2ND LANE NONA CHANDANPUR BARRACKPORE PIN 700122 | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 700122 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.2 L+₹14,022.29 (6.67%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L3 | Rejected-Finance L3 |
Tender Value
₹2.2 L
EMD Value
₹4,480
Closing Date
16 Aug 2024, 12:00 pmClosed
AE,SKHESD I
O/o The Assistant Engineer South Kolkata Health Electrical Sub Division-I, P.W.Dte. K.S.Ray T.B. Hospital, Jadavpur, Kolkata - 700 032
Construction of District Drugs Control Office at Garfa PHC Kalikapur Matongini Hospital, South 24 Parganas.--------Electrical Installation Work.
2024_WBPWD_692518_2
WBPWD/AE/SKHESD-I/NIQ-01/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Garfa PHC
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,480
O/o The Assistant Engineer South Kolkata Health El
23 Oct 2024
15 Jul 2024
20 Aug 2024
16 Jul 2024
16 Aug 2024
24 Jul 2024
23 Jul 2024
Amount
S/F of 0.5 inch. Thick 'FR' Hylam (Phenolic laminated) sheet (2 ft x 3 ft) on wall with necessary nuts bolts etc. as required incl. S/F 1 nos. 230 Volt, 32 Amp cut out (approved make) & 2 x 6 sq. mm. insulated 'FR' copper wire ( 3 mtr. Approx) for meter loop for installation of 1 no. single phase meter as per direction of E.I.C.
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment, as directed by EIC.
a) S& F of DP 40A MCB. (Make-Legrand/ABB/Schneider)
b) S& F of DP 10A MCB. (Make-Legrand/ABB/Schneider)
S&F 415V 2+16 way double door SPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, as directed by EIC. . Incoming - 220V 40A DPMCB isolator(1no) Outgoing - 10KA 6-32A SPMCB-(16nos) (Make-Legrand/ABB/Schneider)
Distn. wiring in 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC in single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/ Finolex /Polycab/Havells/Mescab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make- Legrand, Arteor/Myrius) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish,as to GS. [Average run 10 mtr]
Distn. wiring in 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC in single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/ Finolex /Polycab/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Make- Legrand, Arteor/Myrius) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish., as to GS. a) On Board
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Make- Legrand, Arteor/Myrius), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as to GS.
Supply & laying of 1.1KV single core stranded FR PVC insulated & unsheathed copper wire (RR Kabel/ Finolex/ Polycab/ Havells/Mescab) in 19/25 mm dia polythene pipe after cutting channel of suitable size, concealed in wall, incl. mending good the damages, as directed by EIC. .
2x6sqmm + 1x4sqmm [Meter to SPNDB]
2x2.5sqmm + 1x1.5sqmm [for Power plug/Computer]
3x1.5sqmm
Finising the end of above PVC insulated & unsheathed copper wire.
2x6sqmm + 1x4sqmm [Meter to SPNDB]
2x2.5sqmm + 1x1.5sqmm [for Power plug/ Computer]
3x1.5sqmm
Supply of Endura LED Bulkhead light fitting (Philips cat. No. WT 202W LED 6S NCW PSU S2 PC) on surface on wall /ceiling etc. as per direction of EIC.
Supply of Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 502 1xT-LED 22W/ Crompton/wipro having similar specification). incl S&D 1x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 18W 2100 Lm 865 T8 (Pc) (1200 mm)/ Crompton/ wipro having similar specification ), as per direction of E.I.C.
Supply & delivery of 14watt LED Bulb. (Make: Philips/Crompton/Wipro)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length, as per G.S.
Fixing only bulk head ceiling fitting on wall by screws etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box, as to GS.
S & D 48″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. The capacitor of fan must be P-2 type brust proof. (Make - CG HS PLUS / Orient summercool having Similar Specification)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire, as to GS.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc., as per G.S.
Supply of 400 mm(16") dia double ball bearing full metal body wall bracket fan [Make: EPC/Cinni], as directed by EIC.
Supply of Heavy Duty Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Electrical Pvt. Ltd. ) 9"( 230mm ) Speed 920 RPM .
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter.
Fixing only 9"( 230mm ) louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long).
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level, incl. excavation of approx 1 m3 of soft soil for installation of Earth Electrode and filling & ramming, by ISI-Medium GI Pipe for soft soil.
Connecting the 1X10SWG equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. as per GS.
GUHA ENTERPRISE
MAA TARA ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .