Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹27.8 L Quoted ₹31.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹32.9 L+₹98,520 (3.09%)Rejected-Finance | ₹32.9 L+₹98,520 (3.09%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹32.9 L+₹1.0 L (3.20%)Rejected-Finance | ₹32.9 L+₹1.0 L (3.20%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹36.8 L+₹4.9 L (15.4%)Rejected-Finance | ₹36.8 L+₹4.9 L (15.4%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹38.1 L+₹6.2 L (19.3%)Rejected-Finance | ₹38.1 L+₹6.2 L (19.3%) | L5 | Rejected-Finance Rejected |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 May 2024, 6:00 pmClosed
GE Faridkot
GE Faridkot Mil Stn
Repair maint of summer appliances including ceiling fans exhaust fans wall mounting fans and allied works at Faridkot Mil Stn
2024_MES_651396_1
GE FRD-10/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE Faridkot
CLASS D b i
9 documents required · 9 mandatory
₹500
GE Faridkot
₹1 L
20 Jun 2024
27 Apr 2024
29 May 2024
27 Apr 2024
27 May 2024
13 May 2024
Amount
Taking down unserviceable compressor of any make/model of Water Cooler of capacity 40/80 litres and S&F new sealed unit compressor as per existing make, hermetically sealed including flushing out system,rectification of leakage by soldering/brazing, gas charging of adequate qty and testing on load complete all as specified and directed .
All as per Ser Item No 01 here in before but sealed unit compressor suitable for water cooler of capacity 60/120 Ltrs, complete all as specified and directed .
S&F in replacement Copper filter and capillary tube as per existing for water cooler complete all as specified and directed .
S&F in replacement for Relay with over load protectors for water cooler complete all as specified and directed .
S&F in replacement for Condensor fan motor of capacity 1/25 HP, 1400 RPM, 230 volts AC for water cooler complete all as specified and directed .
S&F in replacement for Thermostat switch with knob as per existing for water cooler complete all as specified and directed .
S&F in replacement for Drip tray made out stainless steel sheet(as per sample) for water cooler complete all as specified and directed .
S&F in replacement for Push tap, any colour, high pressure of PTMT, screwed for iron pipe of 15mm bore (as per sample) for water cooler complete all as specified and directed .
S&F in replacement for Running capacitor of 10 Mfd 240 volt AC Supply for water cooler complete all as specified and directed .
S&F in replacement for Starting capacitor 40/60 Mfd 240 volt AC Supply for water cooler complete all as specified and directed .
S&F in replacement for Fan blade for condensing fan motor for water cooler complete all as specified and directed .
S&F in repalcement of condensor unit with fixing arrangement of 40/80 Ltr water cooler complete all as specified and directed.
S&F in repalcement of condensor unit with fixing arrangement of 60/120 Ltr water cooler complete all as specified and directed.
M&L for charging of Gas of water cooler having cooling capacity 60/120 ltrs including flushing out system, checking and rectification of leakages, testing for satisfactory functioning complete all as specified and directed.
M&L for charging of Gas of water cooler having cooling capacity 40/80 ltrs including flushing out system, checking and rectification of leakages, testing for satisfactory functioning complete all as specified and directed.
M&L for cleaning the housing from inside & outside, cooling system, cooling coil, condenser, capillary tube complete washing by blower and carbon tetrachloride liquid and testing of water cooler of 40/80 litres and 60/120 litres capacity complete all as specified and directed.
Taking down unserviceable compressor of any make/model of AC 1.5 TR capacity and S&F new sealed unit compressor as per existing make,hermetically sealed including flushing out system, rectification of leakage by soldering/brazing, gas charging of adequate qty and testing on load complete all as specified and directed .
All as per Ser Item No 17 here in before but suitable for split type AC of 2.0 TR capacity complete all as specified and directed .
S&F in replacement for Condensor fan motor of outdoor unit as per existing capacity suitable for split type AC 1.5 TR capacity complete all as specified and directed .
S&F in replacement for Blower motor of indoor unit (AC/ DC type) as per existing capacity suitable for split type AC complete all as specified and directed .
S&F in replacement for Running capacitor clip type of capacity 36 MFD, 240 volts, 50 cycles suitable for split type AC complete all as specified and directed .
S&F in replacement for Running capacitor clip type of capacity 80-100 MFD, 240 volts, 50 cycles suitable for split type AC complete all as specified and directed .
S&F in replacement for Capacitor of capacity 50/45 MFD, 240 volts, 50 cycles suitable for split type AC complete all as specified and directed .
S&F in replacement for Capacitor of capacity 100-120 MFD, 240 volts, 50 cycles suitable for split type AC complete all as specified and directed .
S&F in replacement for Over load protector with relay suitable for split type AC complete all as specified and directed .
S&F in replacement for Thermostat switch suitable for split type AC complete all as specified and directed .
S&F in replacement for Condensing fan motor blade of outdoor unit of split type AC 2.0 TR capacity complete all as specified and directed .
S&F in replacement for Air filter 5 micron as per existing size & make of split type AC complete all as specified and directed .
S&F in replacement for Expansion valve as per existing size & make of split type AC complete all as specified and directed .
S&F in replacement for Blower for window type AC complete all as specified and directed .
S&F in replacement for Blower for split type AC complete all as specified and directed .
S&F in replacement for Sensor for indoor unit of split type AC complete all as specified and directed .
S&F in replacement for Evaporator Coil for AC complete all as specified and directed .
S&F in replacement PCB Card for split type AC of capacity 1.5 TR as per existing make and model complete all as specified and directed .
S&F in replacement PCB Card for split type AC of capacity 2.0 TR as per existing make and model complete all as specified and directed .
S&F in replacement PCB Card for inverter type AC as per existing make and model complete all as specified and directed .
S&F in replacement Remote hand set for split type/Window type AC 1.5/2 TR capacity complete all as specified and directed .
S&F in replacement Brass Valve 1/2 " ,1/4 " and 5/8 " for AC complete all as specified and directed .
S&F in replacement Connector unit for AC complete all as specified and directed .
S&F in replacement drainout pipe for AC complete all as specified and directed .
S&F in replacement Swing motor of existing make for AC complete all as specified and directed .
S&F in replacement Mounting stand for outdoor unit of split type AC complete all as specified and directed .
S&F in replacement Foam type insulating flexible pipe fitted on suction/ discharge copper tubes for AC complete all as specified and directed .
S&F in repair internal wiring kit of PVC insulated copper conductor wire for AC of any capacity , make and model complete all as specified and directed.
M&L in repair for cutting of burnt winding of blower/condensing motor of split type AC of any make and rewinding with super enamelled copper winding wire of existing size and weight including replacement of bushing complete all as specified and directed. .
M&L in replacement of condensing unit of AC of any type (as per existing) complete all as specified and directed.
M&L for charging of Gas of Split/Window AC of existing make and 1.5 TR capacity including flushing out system, checking and rectification of leakages, testing after completion for satisfactory functioning complete all as specified and directed
M&L for charging of Gas of Split/Window AC of existing make and 2.0 TR capacity including flushing out system, checking and rectification of leakages, testing after completion for satisfactory functioning complete all as specified and directed
Servicing and maintenance of AC of capacity 1.5 /2.0 TR (window type/split type) of any make with blower and chemical wash complete all as specified and directed.
M&L for replacement of copper pipe of size 1/4 " from outdoor unit to indoor unit of AC including soldering and brazing complete all as specified and directed.
M&L for replacement of copper pipe of size 1/2 " from outdoor unit to indoor unit of AC including soldering and brazing complete all as specified and directed.
M&L for replacement of copper pipe of size 5/8 " from outdoor unit to indoor unit of AC including soldering and brazing complete all as specified and directed.
Taking down existing split/window type AC of capacity 1.5/2 TR and refixing in other location including testing for satisfactory functioning complete all as specified and directed .
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 4 Sqmm for continous earth wire drawn into existing PVC concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor shall be measured as one length)
S&F in replacement Sheet Metal single pole and neutral Enclosures with a two pin and earth plug and socket with MCB SP 10 Amps suitable for working on 240 volts AC complete all as specified & directed.
Taking down unserviceable compressor of any make/model of refrigerator of capacity 286/310 Ltrs and S&F new sealed unit compressor as per existing make, hermetically sealed including flushing out system, rectification of leakage by soldering/brazing, gas charging of adequate qty and testing on load complete all as specified and directed .
All as per Ser Item No 56 here in before but for 180/210 Ltrs capacity refrigerator complete all as specified and directed .
Taking down unserviceable compressor of any make/model of deep freezer of capacity 300 Ltrs and S&F new sealed unit compressor as per existing make,hermetically sealed including flushing out system, rectification of leakage by soldering/brazing, gas charging of adequate qty and testing on load complete all as specified and directed .
All as per Ser Item No 58 here in before but for 400 Ltrs capacity deep freezer complete all as specified and directed .
M&L for charging of refrigerant gas in refrigerator /deep freezer of 310 ltrs capacity including pressure/leak testing etc complete all as specified and directed .
M&L for charging of refrigerant gas in refrigerator of 210 ltrs capacity including pressure/leak testing etc complete all as specified and directed .
M&L for charging of refrigerant gas in deep freezer of 400 ltrs capacity including pressure/leak testing etc complete all as specified and directed .
S&F cooling coil of refrigerator of capacity 210/310 ltrs including connected works complete all as specified and directed .
S&F cooling coil of deep freezer of capacity 300/400 ltrs including connected works complete all as specified and directed .
S&F starting capacitor, 60-80 Mfd for refrigerator complete all as specified and directed.
M&L for replacement of relay suitable for refrigerator/deep freezer of capacity 280/310/ 400 litres complete all as specified and directed.
M&L for replacement of relay suitable for refrigerator of capacity 210 litres complete all as specified and directed.
M&L for replacement of thermostat automatic `R' frost with knob suitable for refrigerator complete all as specified and directed.
M&L for replacement of freezer assembly of refrigerator (any make) of capacity 280/310 Ltrs complete with screws, jointing of tubes etc and testing complete all as specified and directed.
M&L for replacement of freezer assembly of refrigerator (any make) of capacity 210 Ltrs complete with screws, jointing of tubes etc and testing complete all as specified and directed.
M&L for replacement of condensor unit of refrigerator/ deep freezer of capacity 280/310 Ltrs of any make including jointing of tubes and testing etc. complete all as specified and directed
M&L for replacement of condensor unit of refrigerator of capacity 210 Ltrs of any make including jointing of tubes and testing etc. complete all as specified and directed
M&L for replacement of condensor unit of deep freezer of capacity 400 Ltrs of any make including jointing of tubes and testing etc. complete all as specified and directed
M&L for replacement of fan blade for frost free motor of double door refrigerator/deep freezer of any capacity complete all as specified and directed
Attending complaints of AC, refrigerator, water cooler and deep freezer through skilled machanic and detecting fault including repairing minor defects such as leakage of water, faulty wiring etc complete all as specified and directed.
M&L for rewinding of fan motor,3 speed,1400 RPM, any make & of capacity 1/5 HP of Desert Cooler with super enameled copper wire of appropriate size complete all as specified and directed
M&L for removing old paint (internally and externally) of desert cooler of any capacity, preparing the surface by sand paper and applying two coats of synthetic enamel paint over a coat of red oxide primer using spray gun complete all as specified and directed .
S&F in replacement of Fan motor of capacity 1/5 HP, 1400 RPM, three speed,single phase, suitable for desert cooler complete all as specified and directed .
S&F in replacement of Fan blade of desert cooler complete all as specified and directed.
S&F in replacement of submersible water pump of existing capacity for desert cooler complete all as specified and directed.
S&F in replacement of wood /wool chipd pad set,superior quality for desert cooler of any type complete all as specified and directed.
S&F in replacement of supporting jali of wood/ wool chips pad set, made out of hard mild steel wire and fitted in side louvers for desert cooler of any type complete all as specified and directed.
S&F in replacement of PVC water distributor of 3 outlets with nuts & bolts of desert cooler of any type complete all as specified and directed.
S&F in replacement of PVC elbow suitable for desert cooler (as per sample) of any type complete all as specified and directed.
S&F in replacement of PVC flexible pipe 15 mm dia for desert cooler pump complete all as specified and directed.
S&F in replacement of 3 pin plug top of capacity 5 Amp, AC, 240 Volts complete all as specified and directed.
S&F in replacement of fan motor of 1/5 HP with fixing ring/mounting stand for desert cooler eight screw / clip type (as per sample) complete all as specified and directed.
S&F in replacement of Capacitor 4 mfd, 240 Volt complete all as specified and directed.
M&L in replacement of outer body of desert cooler of any capacity (minimum size of cooler 900x600x600mm) made out of 1mm thick GI sheet including side louvers and front grill complete all as specified and directed .
Taking down PVC/MS desert cooler of any size and make from bracket/ stand, spanning all three side shutters and taking out old wooden chips pad, cleaning outer and inner surface including water tank by rubbing with sand paper or wire brush and oiling/ greasing to motor and pump,refixing taken out parts properly and placing the desert cooler at the same place complete all as specified and directed .
S&F in replacement of voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 volt with accurcy of + 2.5% and of capacity 5 KVA with time delay relay & wall mounting bracket complete all as specified and directed
S&F in replacemet of PVC insulated and FRLS sheathed, circular, flexible, multi stranded copper cable, 3 core of size 1.5 sqmm complete all as specified and directed.
S&F in replacemet of PVC insulated and FRLS sheathed, circular, flexible, multi stranded copper cable, 3 core of size 2.5 sqmm complete all as specified and directed.
S&F in replacemet of metal clad industrial plug 2 Pole + Earth, 250 volts for AC & geyser complete all as specified and directed .
S&F in replacemet of metal clad industrial socket 2 Pole + Earth, 250 volts for AC & geyser complete all as specified and directed .
M&L for Repair/servicing to RO system of capacity up to 50 Ltrs per hour and any type/make by dismantling the accessories carefully after disconnecting the electric connections , taking out defective parts and fixing new parts in position ,assembling the RO system as per original, testing and re-fixing properly at the same place all as specified and as directed. Notes :- Note: Spare parts required for repair shall be measured and paid under relevant items as supply only.
Supply only Pre filter for RO system of capacity up to 50 Ltrs
Supply only Carbon block filter for RO system of capacity up to 50 Ltrs
Supply only UV for RO system of capacity up to 50 Ltrs
Supply only membrane for RO system of capacity 12 to 15 Ltrs
Supply only pressure pump for RO system of capacity 12 to 15 Ltrs
Taking down existing unserviceable ceiling fan 1200mm sweep 230V, AC single phase, cutting unserviceable winding from fan stator & rewinding same with super enameled copper winding wire of existing gauge size including thoroughly cleaning all the components, oiling, greasing etc and refixing in the same position complete all as specified and directed.
All as per Srl item No 103 here-in-before but of size 1400 mm sweep.
Taking down existing unserviceable Exhaust fan 400/450 mm sweep 230V, AC single phase, cutting unserviceable winding from fan stator & re-winding same with super enameled copper winding wire of existing gauge size including thoroughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws and refixing in the same position complete all as specified & directed.
All as per Srl item No 105 here-in-before but size 250/300/380 mm sweep complete all specified and directed .
Taking down existing unserviceable wall mounted fan of Offrs Mess / MES IB / Guest room, 400 / 450mm sweep 230 V, AC single phase, cutting unserviceable winding from fan stator & re-winding same with super enameled copper winding wire of existing gauge size including thoroughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws and refixing in the same position complete all as specified and directed.
Taking down existing unserviceable wall mounted fan of Workshop location 600 mm sweep 230 V, AC single phase, cutting unserviceable winding from fan stator & re-winding same with super enameled copper winding wire of existing gauge size including thoroughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws and refixing in the same position complete all as specified and directed.
Taking down ceiling fans,exhaust fans and wall mounted fans including fittings & fixtures and making good the disturbed area as per existing complete all as specified & directed.
Scraping down old paint of ceiling fan of any size 1200/1400mm sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying sand paper & painting the ceiling fan by means of spray gun/brush with synthetic enamel white paint , writing the MES No with letter of 20mm size on each fan with black paint complete all as specified & directed.
Supply and fixing flexible two core copper cable of size 23/0.0076 complete all as specified and directed.
Supply and fixing in repair Ball bearing Ser No 6201 & 6202 complete all as specified & directed. Make : NBC/SKF
Supply and fixing in repair Ball bearing Ser No 6203 & 6204 complete all as specified & directed Make : NBC/SKF
Supply and fixing in repair Gun metal bush of size as per existing specification Make : as per sample and conforming to ISI complete all as specified & directed.
Supply and fixing in repair Shackle type rubber reel,'U' clamps, bolts,split pin & washer complete all as specified & directed.
Supply and fixing in repair Condenser 3.15 Mfd complete all as specified & directed Make : Standard/Jyoti/Usha
Supply and fixing in repair Condenser 2.5 Mfd complete all as specified & directed Make : Standard/Jyoti/Usha
Supply and fixing in repair Canopy top/bottom suitable for 20mm dia ceiling fan down rod complete all as specified & directed.
Supply and fixing in repair Down rod 300mm long of size 20mm dia for ceiling fan complete all as specified & directed
Supply and fixing in repair Fan blades suitable for 1200mm sweep fan make & type as per sample and directed.
Supply and fixing in repair Fan blades suitable for 1400mm sweep fan make & type as per sample and directed.
Supply and fixing in repair Exhaust Fan blades suitable for 250/ 300 / 380 mm sweep exhaust fan make & type as per sample and directed.
Supply and fixing in repair Exhaust Fan blades suitable for 400/ 450mm sweep exhaust fan make & type as per sample and directed.
Supply & fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter,voltage 230 V,50 Hz,RPM 1200,copper winding of sweep 250mm complete all as specified and directed
Supply & fixing in repair stepped type electronic fan regulator, flush type 5 speed for ceiling fan 1200/1400 mm sweep on the existing phenolic laminated sheet etc complete all as specified and directed
Supply & fixing in repair single phase induction motor for non mettalic ventilating fan of sweep 250/300mm complete all as specified and directed Note :- A Sum of Rs. 4,05,270.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page Nos. 25 & 26 (Schedule of credit) of Tender Documents.
M/S BSS AND SONS
M/s Bansi Lal
NAV DURGA CONSTRUCTION CO
B D BATRA AND SONS
ASHWANI SETHI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .