Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹16.5 L+₹3.2 L (24.3%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹16.7 L+₹3.4 L (25.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹19.1 L+₹5.8 L (43.7%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹21.5 L+₹8.3 L (62.2%)Rejected-Finance BHU | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Dec 2021, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
REPAIR MAINTENANCE / REPLACEMENT OF U/S LT PANELS/FEEDER PILLAR BOX, U/S UNDER GROUND CABLE, RE-ROUTING OF CABLES AND OTHER CONNECTED WORKS AT 7AFH KANPUR CANTT
2021_MES_489055_1
GE(AF)/CHK/T-32 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
7AFH Kanpur Cantt
Class D and cat b(i)
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹50,000
12 Jan 2022
18 Nov 2021
22 Dec 2021
18 Nov 2021
15 Dec 2021
3 Dec 2021
18 Nov 2021 - 27 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding1.5 m in depth for laying of UG Cable including getting out in soft/loose soil complete all as specified & directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and directed.
M & L for spreading & leveling dry clean Ganga sand in trenches for cushioning of UG cable complete all as specified and directed.
M & L for sub class old size Brick in trenches laid across the cable for cable protection complete all as specified and directed.
M & L for boring through existing road with trench less method for passing of UG cable complete all as specified and directed.
S & F XLPE insulated cable of size 300 Sqmm cross sectional area 3.5 core, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable/OH conductor complete all as specified and directed.
Ditto all as per item No.7.00 here-in-before but of size 150 sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 120 sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 95 Sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 70 Sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 50 Sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 25 Sq mm 3.5 core.
Ditto all as per item No.7.00 here-in-before but of size 16 Sq mm 4 core.
S & F 80 mm bore GI pipe of light grade, conforming to IS-1239 laid in trenches/fixed on pole/wall with required size of flat iron clamp duly painted with two coats of super enamal paint over a coat of red oxide primer complete with bolts, nuts and washers complete all as specified and directed.
Ditto all as per item No.15.00 here-in-before but for 50 mm bore pipe.
Supply, Jointing, commissioning and testing Cold Shrinkable end termination joint out door type and suitable for cable of size 120 sq mm 3 core with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable complete all as specified and directed.
Supply, Jointing, commissioning and testing Heat Shrinkable straight though joint out door type and suitable for cable of size 120 sq mm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 25 mm x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point complete all as specified and directed including testing on completion including PCC type C-2 pit of (1:3:6) using 40 mm graded stone aggregates, RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip of size 32 mm x 6 mm protection etc (Earthing result not more than 2 ohm and test result duly signed) complete all as specified and directed. ( Note : Earth strip having length 7.5 Mtr per earthing shall deemed to be included in unit quoted rates).
M & L for laying earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 25mmx4 mm galvanised iron strip complete all as specified and directed.
M & L for replacement of out door type HT Feeder pillar box made out from 3.15 mm MS sheet and angle iron frame, dust and vermin proof, including provision of aluminium bus bar fixed on HT bushing and having suitable provision for connecting up to cable size 120 sq mm 3 Nos complete including necessary earth work/foundation work and making cable connection with suitable size of cable glands complete all as specified and directed.
M & L for Lightning arrestor non lineor resistor type conforming to IS, complete line discharge class -3 nominal discharge current 65 KA and high discharge with stand 100 KA assembly suitable for 33 KV and mounted on existing structure including replacement all clamp nuts, bolts and washer etc complete all as specified and directed.
M & L in replacement of unserviceable existing VCB charger with battery back up system with new consisting sealed maintenance free dry batteries, 15 Nos of Cap 2 Volts, 65 AH, Make : Exide /Amaron/Quanta, complete with batteries stand for mounting of batteries and connecting lead with panel etc complete all as per sample and as specified and directed by Engr-in-Charge.
S & F in replacement heat shrinkable type end termination joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade complete all as specified and directed.
Ditto all as per item No.27.00 here-in-before but for cable size 70 to 150 Sqmm, 3.5 Core.
Ditto all as per item No.27.00 here-in-before but for cable size 185 to 240 Sqmm, 3.5 Core.
Ditto all as per item No.27.00 here-in-before but for cable size 300 to 400 Sqmm, 3.5 Core.
M & L for providing highly skilled mechanic / specialist in power factor / capacitor bank panel to carryout the repair / servicing / overhauling, testing and calibration including test of capacitor, well cleaning with petrol and CRC-226, replacement of unserviceable parts / accessories, like capacitor, coil, relay and other connected captive synthetic current injection test as per IS 14658 : 1999 or IS 13516 : 1993 to check to power improvement system complete all as spefified and directed. (Note :- Spare parts shall be measured and paid seperately under relevant items of Sch 'A').
Supply only spare parts for maintenance of item No.31.00 here-in-before given as under :-
Capacitor 10 KVAR
CT coil
APFC Relay
Digital display meter
Indicator lamp
S & F in repair bacalite fuse grip with HRC fuse of capacity 400 to 630 Amps all as per existing type complete all as specified and directed.
M & L for welding works for unserviceable doors of LT panels / Generator canopy, fixing of hinges etc. at various locations complete all as specified and directed.
M & L for applying two coat of superior quality synthetic oil paint on all exposed surface and internal portion of LT distribution panels including necessary surface preparation of old painted surface complete including marking stencil letter writing with highly fluorescent sheet best quality directly stick to panel as marking / identification of circuits / Area of supply height between 15 mm to 20 mm group of letter not more than 15 letters in each incoming and outgoing MCCBs or distribution cables complete including cleaning the bushes and cleapers all over the panel not less that 1.5 m radius complete all as specified and directed.
M/S Asian Engineers
Preetpowercontrol
Bharat Sales Corporation
Lalta Prasad vijay kumar Forwarding Agency
U K Enterprises
M/S B.S ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .