Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.6 L+₹1.8 L (8.36%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹25.8 L+₹4.1 L (18.6%)Rejected-Finance | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹27.6 L+₹5.9 L (26.9%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF EM NATURE OF WORKS IN PIRU VIHAR UNDER GE WEST DELHI CANTT 10
2022_MES_520772_1
GE/DW-51/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹80,000
10 Sept 2022
1 Jul 2022
29 Jul 2022
2 Jul 2022
27 Jul 2022
15 Jul 2022
Amount
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at Piru Vihar for collection of complaints from the concerned JE in charge. 7 Job slip as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,ceiling light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacity shall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site shall be deposited to MES store Yard.
S&F in Replacement of MS down rod 300 mm for fixing of ceiling fan all as specified and directed
S&F in Replacement of MS down rod upto 1200 mm for fixing of ceiling fan all as specified and directed
S&F in Replacement of Ceiling fan blade 1200mm sweep for fixing of ceiling fan all as specified and directed.
S&F in Replacement of inner shell Copper body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of inner shell Stainless steel body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of Copper Heating Element 1500 watt suitable for Geyser of 25 Ltr capacity complete all as specified and directed.
S&F in Replacement of thermostat suitable to work at water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed.
S&F in Replacement of copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
M&L Replacement of MS outer shell suitable for geyser of capacity 25 ltr complete all as specified and directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) and all fitting fixtures deposited to MES store Yard complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 42 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S & F in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
S & F in Repair of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S & F in Repair of Bell push single pole one way complete all as specified and directed.
S & F in Repair of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S & F in Repair of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F in Repair of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 4.00 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
M&L for rewinding exhaust fan of 300mm/450mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
M&L in repair lower shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
M&L for scarapping/cleaning to rusted/pealing area on surface of ceiling fans including sweeps,down rod,fan Hook after cleaning applied two coats of spray painting and numbering complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, ladder and safety measures to make it functional complete all as specified and directed.
M&L for scarapping/cleaning to rusted/pealing area surface of Meter panel after cleaning applied two coats of spray painting by approved colour and numbering also cleaning area of Meter Room dust and unwanted material to be thrown out at out side of defense permises area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, ladder and safety measures to make it functional complete all as specified and directed.
S&F in Replacement of of Desert Cooler copper fan motor upto cap - 1 to 2 HP complete all as specified .
S&F in Replacement of of Desert Cooler Fan blade suitable for 1 to 2 HP motor including all new nut & bolts complete all as specified .
S&F in Replacement of of Desert Cooler water pump upto cap 20 LPM and 6 mtr head complete all as specified .
S&F in Replacement of of Desert Cooler water PVC tubing 10 mm dia complete all as specified .
M&L removing rusted iron particles by scrapping and applying two coats of aluminum spray painting to desret cooler inner and outer body including S&F in Replacement of of Air Cooler Cooling Pads set of three (conform to sample) with good holding of GI ties & PVC electric 1.5 sqmm copper cable jointing from motor and pump to panel board of cooler complete all as specified .
S&F in Replacement of Halozen Heating element Rod 400 watt capacity for Room heater (Make : Maharaja white line (lava)), including electric connections & testing complete all as specified .
S&F in Replacement of relay assembly/autocut for 1200 watt capacity Room heater (Make : Maharaja white line (lava)), complete all as specified.
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 1200 watt capacity (Make : Maharaja white line (lava))
S&F in Replacement of Halozen Heating element Rod for Room heater 1000 watt capacity (Make : Baltra ) including electric connections & testing complete all as specified .
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 2000 watt capacity (Make : Baltra ) including electric connection and testing complete all as specified .
S&F in Replacement of Halozen Heating element Rod for Room heater 1000 watt capacity (Make : Gopi Heat pillar) including electric connections and testing complete all as specified .
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 2000 watt capacity (Make : Gopi Heat pillar)including electric connections and testing complete all as specified .
S&F in Replacement of Compressor for Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Primary filters Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Secondry filters Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Minarals filter Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Condenser Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Drain tray Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Primary filters Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Secondry filters Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Minarals filter Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Primary filters Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
S&F in Replacement of Secondry filters Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
S&F in Replacement of Minarals filter Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
Deduct Credit: for demolished/dismantled material of (-) Rs 225549.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/s Adhikari construction co.
GAUTAM ELECTRIC WORKS
SETHI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .