Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 1 UPON 18 JAGDAMBA NAGAR FIROZABAD FIROZABAD FIROZABAD UTTAR PRADESH 283203 | FIROZABAD | UTTAR PRADESH | 283203 | Admitted-Finance |
Tender Value
₹8.3 L
EMD Value
₹8,300
Closing Date
31 May 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EUDC FIROZABAD
SE EUDC FIROZABAD
For The Work of Making line for new electric connection under full deposit scheme head at Municipal Corporation Firozabad Site- Swargashram (Cremation Ground) Charbagh under the jurisdiction of EUDD-Chandra Nagar, Firozabad.
2025_DVVNL_1036657_2
EUDC/F/T-09/2025-26
Open Tender
Electrical Works
Lump-sum
60 days
Firozabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer EUDC Firozabad
₹8,300
2 Jun 2025
26 May 2025
31 May 2025
26 May 2025
31 May 2025
26 May 2025
Amount
Carriage following material from Centre Stores, Asfabad to site of work (Distance 00-15 Kms.) through the Kacha and Pakka road including the work of its loading and unloading at the respective ends as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work in the area of EUDC, Firozabad (Material shall be provieded by Department)
Cable 11 Kv (E) XLPE 3x70 mm2 three core Alluminium conductor
STP 11 Mtr. Long
Top Channel 125x65x3200 mm with clamp -2 Nos. Droper Channel 100x50x2600 mm -2 Nos. ACSR Dog Conductor - 35 Mtr. 11 kv Disc Insulator - 06 Nos. 11 kv Disc Fitting - 06 Nos. 11 Kv Insulator - 06 Nos. 11 Kv Pin with Nut -06 Nos. T-off Channel - 04 Nos. Stay set Complete - 04 Nos.
11 kv Pilfer Proof Metering Cubicle
3 Ph-4 W Static TVM 11 kv
11 kv CT/PT Metering Pole Mounted Unit (30/1)
250 Kva, 11/0.4kv Transformer New
11KV VCB for O/G CTR 200/100/5A, 350 MVA
Supply of the Following Material.
140 mm OD PN-4- 80 Grade UV stabilized HDPE Pipe as per Is 4984
Cable jointing Kit suitable for 3x70 mm2 XLPE Cable
G.I. Pipe 6 dia
G.I. Pipe Holding Clamp and Bolt & nut
MS Angle 75x75x6x2028 mm
Stone pad
Earh Wire clamp with bolt & nut
Number Plate
Danger Board With Clamp
Barbed Wire
Alluminium Tape
Alluminium Paint
Red Oxide Paint
Clamp and Bolt & Nut
Only Erection Of Following material
3 Ph-4 W Static TVM 11 kv
11 kv Pilfer Proof Metering Cubicle
11 kv CT/PT Metering Pole Mounted Unit (30/1)
11KV VCB for O/G CTR 200/100/5A, 350 MVA
Cable jointing Kit suitable for 3x70 mm2 XLPE Cable
Laying of following.
Laying of 140 mm OD PN-4- 80 Grade UV stabilized HDPE Pipe as per Is 4984 for laying of 11KV, 3x70 Sqmm, XLPE Cable with HDD (trenchless) method.
Cable 11 Kv (E) XLPE 3x70 mm2 three core Alluminium conductor
Cable 11 Kv (E) XLPE 3x70 mm2 three core Alluminium conductor (Use/Double Riser+Looping+50m for Metering.)
Installation of the new 250 kva transformers at 11/0.4 KV substation Ram Nagar, under the jurisdiction of Electricity Urban Distribution Division [Chandra Nagar] Firozabad, in proper alignment and direction and making proper HT/LT connection as per instruction of Supervising Engineer after carriage the same from Centre Stores, Asfabad including the work of safe loading and unloading at the respective ends and also including the cost of arrangement of laborer, T&P, carrier etc required for proper completion of work.
Erection of 11 M long STP Double Pole Structure including duly grouted in cement, sand and brick ballast in ratio 1:2:4, including work of fitting of all accessories, stone pad and clamps suitable for AB cable. Work will be carried out as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Chemical Earthing of Distribution T/F (Body & Neutral) by GI stipp patti as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
Construction of 250 kva Distribution Transformer plinth of size 5’x6’x5’. The size of plinth shall be of 4’ above the ground level. At the bottom there shall be brick ballast pad of size 5x6’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast properly hammered and rammered as per direction of supervising engineer. On the top of the wall there shall be mesh of 12 mm thick iron rod at distance of 9’’ and RCC work in ratio 1:3:6 [Cement, Sand and grit stone] There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of supervising engineer., and also including the cost of arrangement of labourer, T&P etc required for proper completion of work.
Erection and grouting of stays as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Raod restoration charges for pakka road
M/s APOORWA ELECTRICALS (BID ID -5220909)
M/s ARTI ELECTRICALS (BID ID -5224461)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .