Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC WARD NO 26 RCP TALL COLONY SURATGARH 335804 | GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC VALID | |
| 2 | L2₹8.1 L+₹18,285 (2.30%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹8.8 L+₹82,620 (10.4%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹9.0 L+₹1.0 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹9.3 L+₹1.4 L (17.6%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
11 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SURATGARH
GE (AF) SURATGARH
DAY TO DAY MAINTENANCE OF COMPLAINT OF BR SERVICES IN AKASH VIHAR ZONE A AT AF STATION SURATGARH
2022_MES_518251_1
8937/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹20,000
Yes
26 May 2022
13 Apr 2022
13 May 2022
13 Apr 2022
11 May 2022
27 Apr 2022
60 days
Amount
BOQ (DAY TO DAY MAINTENANCE OF COMPLAINT OF B/R SERVICES IN AKASH VIHAR ZONE ‘A’ AT AF STATION SURATGARH)
Petty repairs to leaking in bib tap, pillar tap, stop cock, Angle valve and low level flushing cistern etc of any description including changing the washer etc, complete all as specified and directed.
S&F in repairs spindles for 15 mm CP brass bib cock/stop cocks etc size 1 nos to 4 nos for full trun fittings/ half truns, complete all as specified and directed.
Removal of air lock/blockage of water in GI tubing 15 mm/20 mm bore cleaning the pipe or fittings etc and refixing the same in position, complete all as specified and directed.
Petty repairs to leakage in by refixing/resecuring in PVC (SWR) pipes/ CI pipes etc, complete all as specified and directed.
Easing of door/windows (Complete for one no of door or window) shutters of any size/any number of pannels for easy closing/opening tightning of hinges or changing the position of hinges adjustments of lower bolts, Sliding bolts etc, complete all as specified and directed.
Taking down shutters of any description etc exc 1 Sqm but nexc 2 Sqm & replacement of worn out damaged secondclass hardwood hanging styles etc & refixing in the same opening complete incl painting two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Dismantling of old U/S grating with trap and fixing new MS chromium plated grating 125mm dia with floor trap / Nahani trap after repair leakage, complete all as specified and directed.
M&L for welding of purpose to repair steel windows/door chowkhats any size to obtain smooth opening & closing complete including cutting existing hinge, complete all as specified and directed.
M&L CP cast copper alloy bib taps with wall flange fancy type of 15 mm bore quarter turn fixed in repair, complete all as specified and directed.
M&L CP Fancy type Pillar cock 15mm bore cast copper alloy with capstan heads rocket type with areator fixed in repair, complete all as specified and directed.
S& F in repair CP angle Valve screwed both end for iron pipe 15 mm bore .
S& F in repair 150 mm round Chromium plated Overhead Rain shower with relvoling joint and shower arm with wall flange 15 mm bore fancy type any colour and fixed in repair, complete all as specified and directed.
S&F in repairs 15 mm dia fancy type chromium plated stop valve, alloy screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F in repairs CP grating with or without hole 100/125 mm dia round fix on floor / nahani trap , complete all as specified and directed.
S& F as in repairs in 15 mm ball valve of PVC complete with aluminum rod with polyplast ball for 15mm dia iron pipe complete all as specified For low level flushing cistern.
S& F as in repairs PVC in connection 15mm dia 60cm long with 2 Nos PVC check nuts with washer , complete all as specified and directed.
S & F as in repairs internal assembly syphonic /non syphonic type for PVC flushing cistern of cap 9/10 Ltr, complete all as specified and directed.
S& F only in repairs 32mm dia PVC waste pipe flexible type for WHB or sink 80 cm long with union, complete all as specified and directed.
S& F in repairs waste coupling fittings brass chromium plated 32mm dia, complete all as specified and directed.
Taking up or down existing unserviceable steel tubing and connections, and S& F new steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc ) Bore of pipe 15mm, complete all as specified and directed.
Taking up or down existing unserviceable steel tubing and connections, and S& F new steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc ) Bore of pipe 20mm, complete all as specified and directed.
Taking up or down existing serviceable steel tubing and connections, including cleaning and refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc ) Bore of pipe 15mm, complete all as specified and directed.
Taking up or down existing serviceable steel tubing and connections, including cleaning and refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc ) Bore of pipe 20mm, complete all as specified and directed.
Cutting chases pinning in making good to facing where required and pointing in CM (1:3) for concealed water tubing etc as in brick walls exc 10 cm but not exc 20 cm girth, complete all as specified and directed.
S& F in repairs small fittings galvanised iron medium grade such as sockets, elbow , nipple up to size 200 mm , tee , union etc for 15mm bore pipe including opening the connected pipe and refixing in the same location (ISI Mark all as directed).
S& F in repairs small fittings galvanised iron medium grade such as sockets, elbow , nipple up to size 200 mm , tee , union etc for 20mm bore pipe including opening the connected pipe and refixing in the same location (ISI Mark all as directed).
S& F in repair 20 mm bore gun metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipe including opening the GI pipe and resecuring the GI pipe in the the same location. (no separate measurements for refixing of pipe will be given), complete all as specified and directed.
Dismantling existing water tank of capacity exceeding 250ltrs and not exc500 ltrs and removal to site, complete all as specified and directed.
Dismantling existing water tank of capacity exceeding 500ltrs and not exc1000 ltrs and removal to site, complete all as specified and directed.
S & F Rotational moulded polyethylene Triple Layer, white colour water storage tanks (cylindrical vertical with closed top) cap 500 Ltr hoisted and fixed in position, complete all as specified and directed.
S& F in repair Rotational moulded polyethylene Triple Layer white water storage tanks (cylindrical vertical with closed top) cap 1000 Ltr hoisted and fixed in position, complete all as specified and directed.
S& F in repair PVC Ball valves 20mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed.
Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipe etc for water tank exc 500 not exc 1000 ltrs capacity of tanks as directed by eningeer -in-charge. (Note: Date of cleaning to be written on the tank after cleaning)
Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipe etc for water tank exc 250 not exc 500 ltrs capacity of tanks as directed by eningeer -in-charge. (Note: Date of cleaning to be written on the tank after cleaning)
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, Type 'B', ISI marked of 110mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, Type 'B', ISI marked of 75 mm bore, complete all as specified and directed.
S& F as in repair PVC (SWR) bend with access door of any radius of 110mm bore, complete all as specified and directed.
S& F as in repair PVC (SWR) bend with access door of any radius of 75mm bore, complete all as specified and directed.
S&F of cantilever bracket for sink or wash hand basin, complete all as specified and directed.
Repairs and resecuring to cup boards including easing of CB shutters, tightning of hinges or handles/knobs hasp and staple etc, complete all as specified and directed.
S&F in repairs stainless steel curtain rod 20-25mm dia fixed with screws including bracket and side caps/knobs (Make : As per sample)
S&F in repairs aluminium handle,150mm size cast type, anodised, ISI marked, complete all as specified and directed.
S&F in repairs aluminium barrel tower bolts, 150mm size cast type, anodised, ISI marked, complete all as specified and directed.
S&F in repairs of mild steel barrel tower bolt 200 mm long stove enamelled black with bright bolt, complete all as specified and directed.
S&F in repairs of mild steel sliding door bolt 300 mm long stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate, complete all as specified and directed.
S& F in repairs Mild steel pressed handles 150mm size, oval type, stove enamelled black, pattern and design as approved by Engr-in-charge.
S&F as in repairs cast brass with mild steel med wt 100mm size Butt hinges including taking down door of any size and refixing in same opening, complete all as specified and directed.
S& F as in repairs Mild steel body window handles (Left or right) any size to steel windows & vents, complete all as specified and directed.
S&F in repairs 40 mm dia cup board knobs fixed with nuts, screws and washers of mild steel bright finish, complete all as specified and directed.(Make : As per sample)
S&F in repairs Galvanised mild steel wire cloth, 0.56mm nominal dia and avg width of apreature 1.18 with tinned tacks, or galvanised wire staples inlcluding cutting, shaping etc, complete all as specified and directed.
Hacking out old broken glass any thickness size, quality or description from wooden/steel frames fixed with wooden beads/metal pinning and S&F 3 mm thick sheet glass in squares not exc 0.50 sqm in each pane fixed with wooden beads or putty (in metal frames etc), complete all as specified and directed.
S&F in repair PVC valve less syphonic action type low level duo flushing cistern coloured with inlet ball valve float and handle incl bracket 10 Liter capacity or equivalent) fixed in repair, complete all as specified and directed.
S&F in repairs Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern , complete all as specified and directed. ( Make : as per sample)
S&F in repairs plastic water closet seat cover white /colour ,closed pattern with flat bottom end cover and mild steel chromium plated hanging device, complete all as specified and directed.
S&F in repairs CP pressure JET for EWC including flexible pipe for 15 mmdia bore, complete all as specified and directed.
S&F in repairs Bib tap 15mm dia standard of PTMT any colour high pressure screwed for iron pipe & fixed, complete all as specified and directed.
Renewing tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles, complete all as specified and directed.
S&F as in repair aluminium door stopper, complete all as specified and directed.
Taking down of existing unsv Seal Door and S&F 4-5mm thick and 50 to100mm width PVC/rubber door seal, complete all as specified and directed.
Supply and fixing in repair 15mm Brass CP wall mixer non telephonical for mixing hot & cold water screwed down for iron pipe and fixed , complete all as specified and directed.
S& F in repair health faucet shower chromium plated with 1.5 mtr flexible pipe and wall hook fixed with EWC suitable for 15mm dia pipe , complete all as specified and directed.
Supply and fixing in repair 15mm Brass CP centre Hole Basin mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
Supply and fixing in repair 15mm Brass CP Sink Mixer for mixing hot & cold water screwed down for iron pipe and f, complete all as specified and directed.
Supply and fixing in repair 15mm Brass CP wall mixer telephonical with L bend for mixing hot & cold water screwed down for iron pipe and, complete all as specified and directed.
S&F, mild steel 150mm, ordinary rat tail door spring etc , complete all as specified and directed.
M & L in repair 18/19 mm Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed.
Notes :- (a) The under mentioned works will be carried out in Zone A Domestic area (OMQ;s) under the area of AGE B/R-II suratgarh (b) All complaints recieved through IVRS , ARMAN App ,telephonically or physically at the Service centrs shall be required to be attended /rectified within the period as specified herein after. (c) Cost of T&P (Incl Ladders) , misc sundry materials , Labours , dresses for labours ,& other safety gears as required shall be deemed to be included in the quoted rates by the contractor for the respective items. (d) The following workers are required per day to address the day to day maintenance works. ( at 09 AM to 05 PM). (i) Highly Skilled Plumber/Pipe Fitter - 01 Nos (ii) Highly Skilled Carpenter _ 01 Nos (iii) Mazdoor/Helper for Pipe Fitter & Carp - 02 Nos (iv) Highly Skilled Mason with one Helper -01 No Each (As & when required) (v) Highly Skilled Welder with one Helper -01 No Each (As & when required).
Notes :- Contd/-- (e) The priority & Duration of complaints to be attended by the contractor shall be as under Priority -I :- To be attended within 24 Hrs ( Complaints Like Leakage in Bib taps ,stop cock , water overflow ,removal of Air Lock ,repairs to door locks . Priority -II :- To be attended within 72 Hrs (Leakage of pipe lines ,flushing cisterns etc & replacement of iron mongery etc , easing of doors & windows etc. Priority -III :- To be attended within 7 Days (Replacement of glass panes , doors & windows parts , PVC connection.flushing cisterns ,cup board repairs , replacement of kitchen sink,plate rack .curtain rods etc If in case a complaint is not resolved within the specified time period the contractor shall be liable for a penalty as under. Rs 250.00 Per Complaint per day after the specified period. In case of any dispute regarding the penalty the decision of the Accepting Officer shall be final conclusive & binding .
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17(R) of tender documents.
M/S Shree Ram Enterprises
GURUJI ENTERPRISES
H S BUILDERS
M/s JUGAL KISHORE MISHRA AND SONS
M/S VISHNU ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .