| 1 | L1₹24.3 LAccepted-AOC C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L1 | Accepted-AOC Being 1st lowest bidder | |
| 2 | L2₹25.0 L+₹65,095.23 (2.68%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest bidder | |
| 3 | L3₹25.2 L+₹91,520.35 (3.76%)Rejected-AOC CHHURTA JHAJJAR KOTLI JAMMU J K 181222 | 181222 | L3 | Rejected-AOC 3rd lowest bidder | |
| 4 | L4₹27.4 L+₹3.1 L (12.7%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC 4th lowest bidder | |
| 5 | L5₹28.4 L+₹4.1 L (16.8%)Rejected-AOC VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L5 | Rejected-AOC 5th lowest bidder |
Tender Value
₹29.6 L
EMD Value
₹59,500
Closing Date
25 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(Army) Dhar Road
GE(Army) Dhar Road
PROVN OF 01XTOILET01XBATHROOM WITH ALLIED INFRASTRUCTURE NEAR GUARDPOST B15 ATTAWI VIHAR PROVNOF PAVERWAY IN FRONTOFOR MD ACCN BLOCK NO NP17 18 OF TAWI VIHAR AND PROVNOF 2XSEPTICTANK SEWAGELINE FOR QTR68 GOVT MDACCN AT PREM VIHAR UNDER GEARMYDHARROAD
2023_MES_627229_1
8069/NIT-61/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE(Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE(Army) Dhar Road
₹59,500
Yes
12 Mar 2024
7 Nov 2023
27 Dec 2023
8 Nov 2023
25 Dec 2023
11 Dec 2023
Amount
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth, for foundation, etc. or for shaft, wells, cespits manholes, piers holes, etc. nexc 10sqm on plan and getting out in any type of soil.
M&L cement concrete 1:4:8 type D2 (40mm graded stone aggregate) in foundations, filling and mass concrete.
M&L Brickwork with subclass ‘B’ bricks, (old size) straight or curved on plan exc 6m mean radius, buit in in CM (1:6) complete all as specified and directed.
M&L Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
Spreading and levelling in layers n.exc 25 cm thick for well ramming including watering as required floor filling
M&L for treating the top surface of filled earth with Pre construction ATT at the rate of 5 litre of emulsion per square metre of surface.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated meterials (soil) n.exc 50m and deposited where directed at alevel n.exc 1.5m above the starting points.
M&L Reinforced cement concrete M-25 using 20mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L Reinforced cement concrete M-25 using 20mm graded aggregatesas in slab supported on walls, beam and columns in floors, roofs , landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
All as per item No 11 above but in coloumns
All as per item No 11 above but in beams, cantilevers, bressummers, lintels over 1.5m span
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L formwork to soffits of suspended slabs such as roof slabs floor slabs, landings and similar work n.exc 200mm thick.
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of concrete square or ractangular.
M&L Form work to rough finished flat surfaces of chullah hoods, chajjas, troughs and similar items in- cluding edges
M&L mild steel TMT steel bars in reinforcement 10mm dia and over cut to length bent to shape required including cranking binding spirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia.
M&L mild steel TMT steel bars 5mm dia and over up to 10mm dia in stirups
Mild steel bars 6mm to 8mm dia (and flat iron where quered) ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips or welded to flat iron complete all as specified.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth withot using extra cement complete all as specified.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces with CM (1:4) finished even and smooth without using extra cement complete all as specified.
M&L for rendering 5mm thick on concrete surface with CM 1:3 in ceilings complete all as specified.
M&L 100mm thick PCC 1:4:8 type D2 (40mm graded aggregate) for floor sub base.
M&L 25mm thick PCC 1:2:4 type B0 (12.5mm graded aggregate) for floor sub base/leveling course complete all as specified.
M&L for coloured Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm , in floors etc. set and jointed in neat cement and including 15mm thick screed bed or bedding of cm 1:4 layer in floor finishes complete all as spd
M&L coloured Glazed ceramic tiles in vertical surface 300 x450x 7mm/ 600x 300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in CM 1:4.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, suppling and fixing in opening as per specification and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rail M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck in side with solvent cement of styles and plain colour of PVC sheet for top rail lock rail and bottom rail, on either side & gap insert for top rail bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed tohether with solvent cement, at site as per specification & drawing.
S&F 100mm long medium weight cold rolled mild steel butt hinges complete all as specified.
S&F Extruded Aluminium alloy handles, fabricated type anodised of 125mm long complete all as specified..
S&F Aluminium anodised barrel tower bolts of extruded section and fixed Of 100mm long complete all as specified..
S&F aluminium alloy, anodised sliding door bolts 200mm long with haps and staples ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F vitreous china white glazed orrisa pattern WC size 580 x 440mm with integral foot rests complete incld "P" or "S" trap but excl flushing cistrern and flush pipe complete all as specified.
S&F in repairs PVC Low level flushing cistern 10 ltr capacity incl internal fittings, sypons, handle, bend etc incl provision of 2 Nos brackets, PVC connection of 450mm long, flush pipe 32mm dia complete all as specified.
S&F vitreous china wash basin, counter top white, size 450x350mm including all fittings brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl cement screed over precast rcc platform complete all as specified.
M&L PVC (SWR) gully traps 125/110mm setting and jointed with solvent cement complete all as specified.
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement of 75mm dia.
M&L 15mm GI tubing 'Medium grade' with all fiting and fixed complete tom wall and celing or laid in floor of fllowing sizes complete all as specified
ditto as per item no above but 20mm bore.
S & F in repairs rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, 500 ltrs capacity complete all as specified.
S&F bib taps, cast copper alloy with crunch or butterfly handle screwed down, fancy type chromium plated screwed for iron pipe or for brass ferrule and fixed of 15mm bore size..
S&F pillar taps cast copper alloy with capston heads chromium plated screwed down high presure, with or without lettered 'Hot and cold' with long screwe shank and fly nuts, fo iron pipe and fixed for 15mm bore.
S&F 15 mm bore stop cock, fancy type, chromium plated with long shank and cup (concealed type), or angle cock screwed down, high pressure screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 15 mm bore stop cock, fancy type, chromium plated or angle cock screwed down, high pressure screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats complte all as specified.
S&F in repairs brass chromium plated 4" (Square) overhead shower with arm 195mm with with swivel joint including fixing to steel pipe or union.
S&F PVC(SWR) pipes, 75mm external dia double socketed in any length with rubber joints, fixed to walls/under floor with PVC brackets/clips including under floor will be coverd in PCC 1: 3:6 as complete all as specified(with epoxy joint)
S&F PVC (SWR) bends suitable for 75 mm external dia complete all as specified
S&F PVC (SWR) junction single, (single T) equal or unequal of 75mm dia
S&F PVC (SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls/ under floor with PVC brackets/clips including under floor will be coverd in PCC 1: 3:6 as complete all as specified.(with epoxy joint)
S&F PVC (SWR) bends suitable for 110 mm external dia complete all as specified
S&F PVC (SWR) junction single, (single T) equal or unequal of 110mm dia
S&F 110mm PVC (SWR) vent cowl.
S&F 100mm dia cast iron soil, waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in trenches or in floors
Preparing new plaster surface of wall and M&L for apply two coat of cement base paint over a coat of primer on external walls.
M & L for applying three coats of white wash on newly plastered surfaces of wall including preparation of new surfaces complete all as specified and directed.
M&L hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to atrue surface for plinth protection
M&L 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone agg )as in plinth protection finishing the cement concrete surface even and smooth without using extra cement.
S&F box type steel ventilator with top hung shutter including hinges steel peg stay complete all as specified
M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade E-165
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane
Supply and laying, jointing 150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed complete all as specified.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm).
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes omplete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes omplete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) in surface channels and drain finish surface even and smooth all as specified
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out any type soil.
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone complete all as specified.
M&L for Machine pressed precast concrete interlocking paver block any shape and size with gray cement and pigment confirming to IS 15658-2006 of 80mm thickness M-40 Grade with grey cement and pigment laying over and including 25mm thick sand cushion incl watter and ramming (Compacted) and joints filled with sand complete all as specified and directed.
M&L sand filling under floors including watering and consolidation
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed.
M&L 2 coats of synthetic enamel paint over a coat of primer including preparation of new stone or corcrete surfaces over 10cm girth or width, not otherwise described.
M&L for reinforced concrete pipes, class NP3, laid and jointed complete with collars 150mm bore laid in trenches complete all as specified.
All as per item No 1 above but exc 1.50m but not exc 3.00 mtr in depth and getting out in any type of soil.
M&L for concrete bed to drain for 150 dia pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) complete all as specified.
S&F Reinforced concrete pipes, class NP2, 150 mm bore laid and jointed complete with collarslaid in trenches and jointed Concrete bed to drain pipes all as specified.
M&L for concrete bed to drain for 200 dia pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2(Using 40mm graded stone aggt) complete all as specified.
S&F Reinforced concrete pipes, class NP2, 200 mm bore laid and jointed complete with collarslaid in trenches and jointed Concrete bed to drain pipes all as specified.
Cleaning of sludge from existing manholes etc of any capacity and depth by dewatering, taking out mud/ sludge/quid, getting out and removing & depositing the sludge, for new connection complete all as specified and directed. also dewatering/Sludge to be thrown away outside of defence area.
S&F salt glazed stoneware gully traps of size 150 x 150 mm, square or round mouthed, type "P" fixed in CM 1:6 and cover with RCC cover slab of size 200 x 200 x 50 mm complete all as specified.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM(1:4) finished even and sooth w/o using extra cement
Supply only liquid water proofing compound
M&L for RCC type B-1 (1:2:4), using 20 mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Framed work as in opening of manhole of angle or other section with gusset plates, also fastening and fixing conforming to Fe-410 W Gide E-290, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, incl forms, moulds,mitred/stopped ends etc complete all as specified and directed
Construction of septic tank for 100 users (Brick constructions) complete all as specified and as shown on drawing No. CE/TD-1202/2003 sheet 1/2 & 2/2 respectively.
Construction of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed with brick masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 3.0 M effective depth as shown on drawing No. CE/TD-1202/2003 sheet 1/2 & 2/2 respectively.
M & L for concealed point wiring on wall and in existing conduit or on surface conduit on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.2 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and finishing new surfaces complete all as specified and directed by Engineer-in-Charge for the following:-
One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
One switch socket outlet point 3 pin 5 Amps on Independent board.
One switch socket outlet point 3 pin 5 Amps on same board.
Material and labour for Point wiring complete with 2 run of 2.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including suitable size of PVC white non metalic conduit with all accessories like tee, straight joint, L Bend etc., concealed on wall surface on ceiling / roofs etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 2.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.2mm thick fixed and flushed inside the walls, with 3mm thick bakelite laminated sheet top cover for housing the switches/socket outlets 15 Amps.complete all as specified and directed by Engineer-in-Charge
Supply and fix LED mirror wall light/Mirror light fitting 10 watt , 230 volt, 50 Hz complete with LED light complete all as specified and directed by Engineer-in-Charge
S&F Wall mounted LED batten 18 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv fittings any type complete all as specified and directed by Engineer-in-Charge
Supply and fixing PVC body ventilating fan with louvers fan AC single phase 230 volts for size 250 mm sweep, PVC body 250mm sweep RPM not less than 1100, air delivery not less than 720 cubic meter per hour, power consumption not more than 45 watt complete all as specified and directed.
S&F LED building security light 30/35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 1.2 mtr and fixed to wall with 2 Nos MS Clamp made out of 25mm x4mm flat iron and fastener complete all as specified and directed by Engineer-in-Charge
Supply & fix Electric Storage water heater of capacity 25 Ltr , 230 V BEE star rating 5 complete all as specified and directed by Engineer-in-charge.
S & F ceiling rose Ceiling rose, 3 terminal/PVC/polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge
Supply and fixing socket outlet 5/6Amp 230 volt ISI Mark complete all as specified and directed by Engr-in-Charge.
Supply and fixing Switch , single pole, one way 5/6 Amp 230 Volt ISI Mark complete all as specified and directed by Engineer-in-Charge
Supply and fixing socket outlet 15/16 Amp 230 volt ISI Mark complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch , single pole, one way 16 Amp 230 volt ISI Mark complete all as specified and directed by Engr-in-Charge.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 42 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed by Engr-in-Charge.
Supply & Fixing MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed by Engr-in-Charge.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed by Engr-in-Charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nuts, bolts, reducers, nipples, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB compete all as specified as shown in electrical plateNo. 3 of SSR Part-I and testing of earth resistance as required complete all as specified & directed by engr-in-charge.
Supplying ,Laying and testing complete GI tube medium grade 20 mm bore with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of Gate valve 20 mm bore complete all as specified and directed by Engineer-in-Charge.
Cutting/making conection into CI/DI/MS pipes upto 80mm/100 mm carefully and insertion of new tee incl clamping with suitable size clamp for taking small branch connection upto 25 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core complete all as specified and directed by Engineer-in-Charge.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness shall be considerd for measurment purpose
S & L brick burnt for protection of cable sub class B bricks laid dry flat across the cable with length of whole brick complete all as specified and directed by Engineer-in-Charge.
JINDAL BUILDERS
MandeepConstructionCo
DAVINDER SINGH
NARESH KUMAR KHAJURIA
MAHADEV ENTERPRISES
sohtra and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .