| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.4 LAccepted-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | ₹5.4 L | 1 | Accepted-Finance 1 |
| 2 | 2₹5.7 LRejected-Finance D 981 ASHOK NAGAR GALI NO 12 SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110031 | ₹5.7 L | 2 | Rejected-Finance 2 |
| 3 | 3₹6.1 LRejected-Finance SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | ₹6.1 L | 3 | Rejected-Finance 3 |
| 4 | 4₹6.1 LRejected-Finance H NO 732 BURARI VILLAGE DELHI 110084 | NORTH | DELHI | 110084 | ₹6.1 L | 4 | Rejected-Finance 4 |
Tender Value
₹6.7 L
EMD Value
₹13,300
Closing Date
6 Mar 2026, 11:00 amClosed
EEE/KPZ
EEE/KPZ
Upgradation of Electrical and other allied works in MCD Schools -MCPS Shakti Nagar Girls School in ward-69 / KPZ.
2026_MCD_268936_1
TC/ENGG./EEE/KPZ/2025-26/55.1
Open Tender
Electrical Works
60 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹13,300
6 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI. box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as reqd. Group-C
Supplying and fixing following modular type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch
3 pin 5/6 amp socket out let
Supplying and fixing following size / modular, GI box alongwith modular base & cover plate for modular switches in recess etc as reqd. 3 Module (100X75 mm)
6 Module (200mmX75mm)
Supplying and fixing modular blanking on the existing modular plate & switch box excluding modular plate as reqd.
Supplying and fixing suitable size box with modular plate in front on surface or in recess including providing and fixing 3 pin,5/6 amps modular socket outlet and 5/6 amps modular switch connection etc as required.
Supplying and fixing suitable size box with modular plate in front on surface or in recess including providing and fixing 6pin,5/6 amps and 15/16amps modular socket outlet and 15/16amps modular switch connection etc as required.
S&F extra conduit down rod of 20 cm length GI pipe 15 mm dia , heavy gauge i/c painting etc as required. (note: more than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.
Supplying and fixing PVC batten /angle holder including connection etc. as reqd.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5 sq. mm + 1x2.5 sq. mm earth wire
4x2.5 sq.mm + 2x2.5 sq.mm earth wire
2x4 sq mm + 1x4 sq.mm earth wire
4x4 sq mm + 2x4 sq.mm earth wire
2x6 sq. mm + 1x6 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole and neutral
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
Supplying and fixing following Rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), Having a sensitivity current 30 mA in existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size in the existing masonry open duct as required. Upto 35 sq.mm
Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size on wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle)
Supply of XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1KV grade conforming to IS-7098 (b) 2x6 sqmm
Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 0.5mm) 18 - 22 watt
LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >-120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 watt
P&F of water/weather proof junction /pole box made out of hot press moulded sheet moulding (SNC) compound fire retaradant (temp. resistance upto 200 C) of size 200 X 160 X 98 mm (NS) complete with Suitable arrangement for fixing of 2 nos of 6 to 32 amp one No SP-MCB(6to32Amp) & 63 amp Double pole Isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channel with 2 nos of MS clamp with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
S & F of compartmentalized cubical panel board duly powder coated made out of 16 SWG MS sheet with Al. bus bar i/c interconnection copper wiring arrangement for mounting for switchgears, change over switches ,MCCB i/c making the foundation brick work /angle iron frame on floor/wall with proper locking arrangement etc complete as required at site. upto depth 30 cm
Supply of 12" ( 300mm sweep) exhaust fan heavy duty complete with shutter, blades etc as required
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*16 sqmm
SITC of wall mounted fan 400mm sweep 1400 rpm rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan i/c external connectionswith 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supply of 9 Watt LED retrofit lamp suitable for B22 holder
Supplying and fixing of full stainless steel body self contained drinking water cooler with cooling capacity 150 ltr/ hr, storage capacity 150 ltr and suitable for 230V supply as required.
Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required.
SITC of Single phase monoblock pump set complete with all accessories workable on 240/415 volts 50 Hz ac supply (a) 1 HP (0.75 kw) single phaase pump set head from 12-30 mtr suction and delivery 25x25 mm
supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender_condition.pdf
Tender Documents • 0.43 MB
MCD_GCC_Circulars_2025.pdf
Tender Documents • 12.97 MB
BOQ_313016.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid