Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.4 L+₹96,089.07 (2.50%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹39.4 L+₹98,868.20 (2.57%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹40 L+₹1.6 L (4.12%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹42.9 L+₹4.5 L (11.7%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Jul 2020, 6:00 pmClosed
SH MV SANKAR CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO SHIPS GALLEY BUILDING NO P 118 AT INS MANDOVI UNDER AGE I MANDOVI
2020_MES_345829_1
85264/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
AGE I MANDOVI
₹90,000
Yes
12 Oct 2020
19 May 2020
16 Jul 2020
19 May 2020
14 Jul 2020
30 Jun 2020
Amount
Schedule 'A' -Part I ( B&R Works)
Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 part of water and allow to dry for 04 hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat/ Waterseal concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as specified and as directed.
M&L for rendering 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement. Note :- Integral water proofing compound shall be measured and paid separately.
Supply only water proofing compound all as specified and as directed
M&L for chipping , removing carefullly the concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as specified and as directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc complete and applying two coats of alkaline rust converting primer FEOVERT conforming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB all as specified and as directed.
M&L for replacement of steel reinforcement with TMT CRS bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB all as specified and as directed.
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 mm center to center in staggered manner or as directed in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum of about 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for Injecting of site cement slurry grout, in the ratio 1:2 (1- Cement, 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs of cement mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled for repair to wall & slab all as specified and as directed.
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materials :mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching .Grouting maintain the pressure at exit 0.5 to 1.0 kg/cm2 by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements at the rate of 100ml per nozzle. Repeat the process for all the nozzles in beam and columns all as specified and as directed.
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all as specified and as directed.
M&L for building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5 Cement-15 sand) -in damaged areas in 30mm thickness including leveling profiling etc all as specified and as directed.
M&L for providing and applying jacketing around columns with micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specifications complete. Notes: (i) Reinforcement shall be measured and paid separately. (ii) Quoted rates shall include for jacketing, formwork and micro concrete.
M&L for rendering 5mm thick over gunniting / concrete surface and finished the surface even and smooth without using extra cement in cement mortar 1:4 all as specified and as directed
M&L for pre - cast cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate block masonry with solid blocks exxceeding 10 cm built in cement mortar 1:6 all as specified and as directed
M&L for TMT steel bars CRS 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M & L for TMT CRS bar 5mm dia and over upto and including 10 mm cut to length, bend to shape required including cranking bending & hooking ends & binding with mild steel wire (annealed) not less 0.9mm dia for stirrups/binders all as specified and as directed.
M&L for TMT CRS bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc all as specified and as directed.
M & L for nominal mix of concrete for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like type B1 ,1:2:4 using 20 mm graded stone aggregate all as specified and as directed.
Dismantling PCC Floor, hearth or wall tiling including cement mortar Bedding, removing serviceable tiles to stores and removing debris to a distance exceeding 250 m and not exceeding 1000 m spread and levelled all as specified and as directed.
M&L for screed bed or bedding layer of mortar 20 mm thick cement plaster 1:6 for laying floor finishes to receive floor tiles all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:4 to receive tiles in vertical surfaces as a backing coat all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for makrana white Marble tiles 30cmx20cm x 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing all as specified and as directed.
M & L for granite tiles 20mm thick of any type machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surfaces / skirting 350 x 250 x7 mm / 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour as specified and as directed.
M & L for non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sq m in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour all as specified and as directed.
M&L for chamfering and rounding the straight cut edges of stone slab such as in steps , cooking platform and other similar situations complete all as specified and as directed.
Taking down chowkats or frames not exceeding 1.5 sq.m. each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 sq.m and not exceeding 4 sqm each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed.
S & F Second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
S & F 40 mm thick second class hard wood plain,framed,panelled shutters (any number of panels), with panels of timber flat on both sides, (feather edged ), or of veenered particle board medium density, wood particle board with commercial face veeners; fitted to chowkats complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description over 10cm width or girth all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on old wooden surfaces of any description over 10cm width or girth including preparation of surfaces all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on old steel surfaces of any description over 10cm width or girth including preparation of surfaces all as specified and as directed.
S&F 100mm X 63 mm size factory made FRP door frame , fixed with 3.Nos on either side with MS flat iron 25 mm x 3 mm cut to size & made to shape & fixed as in hold fast after necessary tarring , sanding and fixed as per manufacturer’s instructions. Thickness of FRP lamination shall be 2 mm. Core shall be polyurethane foam/ high density (more than 40kg per cubic meter) cellular foam done in situ. Second class wooden blocks shall be provided to hold the fittings .The size of the chowkats shall be inclusive of 2mm thick FRP lamination all as specified and as directed.
S &F Factory made paneled FRP door shutter , 30 mm thick with 2 mm FRP lamination top rail of size 30 x 150 mm , lock rail & bottom rail of size 30 x 150 mm with 12 mm thick panels of FRP section of box type construction as per IS 4020 core shall be polyurethane foam / high density ( more than 40 Kg per cubic meter ) cellular foam done in situ & fixed in position as per manufacturer’s instructions all as specified and as directed.
S&F Stainless steel butt hinges medium weight of 100 mm size all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 150 mm all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified and as directed.
S & F 125 mm long extruded aluminium alloy handles, fabricated type, anodized all as specified and as directed.
M&L for forming jambs etc to openings including cuttings toothings and bondings into old work including facing and pointing to match existing work complete in cement mortar 1:6 all as specified and as directed
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squared exceeding 0.5 sqm each pane all as specified and as directed.
S&F 4mm thick figured glass ,pin head type and glazing with oil putty in squared exceeding 0.5 sqm each pane all as specified and as directed.
S & F Aluminium alloy wire cloth, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and as directed.
Taking down 15 mm bore steel tubing and connections all as specified and as directed.
Taking down 20 mm bore steel tubing and connections all as specified and as directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm all as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25 mm all as specified and as directed
S & F in repair stop valve of PTMT of any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms/ 20mm- 92gms) in dia 15 mm pipe all as specified and as directed
S&F in repairs pillar taps of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-110gms) 15mm bore dia all as specified and as directed
S & F in repairs bib tap standard of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms/20mm- 125gms).15 mm bore pipe all as specified and as directed
S & F PVC Connection of size 15 mm ,450 mm long with PTMT nuts all as specified and as directed
S&F in repair PTMT soap dish approximate size 160 x 160 x 90 mm embedded in wall all as specified and as directed
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and as directed
Dismantling water tanks of capacity execeeding 500 Ltr and not execeeding 1000 Ltr and removing to store all as specified and as directed
S & F 1000 Litre rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed
S & F in repairs wash basins, Vitreous China (flat back, white) 550 mm x 400 mm size, including cutting for and pinning in ends of brackets or erecting stand, fixing of CP waste fitting and waste pipe all as specified and as directed
S & F Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat cover all as specified and as directed
S & F in repairs 10 litres Capacity PVC valveless ,syphonic action type, flushing cistern ,low level,white with inlet,ball valve,float and handle including brackets & Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern & fixing in repair high or low level flushing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any all as specified and as directed
S & F in repairs 5 litres Capacity PVC valveless,syphonic action type,flushing cistern,low/high level,white with inlet,ball valve,float and handle including brackets & Flush pipe of polyethylene of low or high density and connections to pipes and fixing of chain and pull, or lever, if any for urinals all as specified and as directed
S&F Vitreous China urinal , full stall type ,white (excluding flushing cistern, flush pipe and waste pipe ) & fixing of vitreous china urinals , bowl type (back or corner wall type) complete including providing and fixing plugs, bedding urinals against wall in cement mortar 1:2 securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with brackets , flush pipe grating and union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern trap and waste pipe) all as specified and as directed
S&F in repairs swivel shower of PTMT any colour for fixing with 15 mm pipe. (Minimum weight 40gms) & Shower arm 15 mm size, 195 mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) all as specified and as directed
S&F in repairs ball valves 25mm bore dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms) all as specified and as directed
S&F 25 mm bore CPVC ball valve all as specified and as directed
S&F 25 mm CPVC tank adaptor all as specified and as directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed
S&F 110 mm bore PVC (SWR) pipes single socketed in any length solvent cement jointed fixed to wall / column all as specified and as directed
M&L in repairs for 75 mm PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and as directed
S&F 50mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc all as specified and as directed
S&F 110 mm bore PVC (SWR) bends of any radius with access door all as specified and as directed
S&F 75 mm bore PVC (SWR) bends of any radius with access door all as specified and as directed
S&F 110 mm bore PVC (SWR) junction single .single T equal or unequal with access door all as specified and as directed
S&F 75 mm bore PVC (SWR) junction single .single T equal or unequal with access door all as specified and as directed
S&F 75 mm PVC(SWR) vent cowl all as specified and as directed
S&F 110 mm PVC(SWR) vent cowl all as specified and as directed
S & F PVC (SWR) floor trap 75 mm with grating including jointing with solvent cement all as specified and as directed
S&F 19 mm dia decorative aluminium anodized alloy curtain rod fixed with two brackets in each window length all as specified and as directed
Taking down cement plaster of stone /PCC block /brick wall / top of chajja, or concrete surface of any description including raking out joints hacking for key securing down with water etc and removal of debris to outside of INS Mandovi Area including filling of open joints in cement mortar 1:6 all as specified and as directed
M&L for 5 mm thick plastering in cement mortar 1:3 finished even and smooth without using extra cement on ceiling all as specified and as directed
M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces with liquid WPC as per manufacturer instruction complete all as specified and directed finished even and smooth without using extra cement all as specified and as directed Note - WPC will not be measured and paid separately
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even and smooth without using extra cement all as specified and as directed
M&L for preparing new plastered surface of wall of any description preparatory to distempering, applying 1mm thick acrylic wall care putty on wall, Priming plastered and other surfaces with alkali resistant priming paint, & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed
M&L for complete removal of existing treatment for preparation of old plastered surfaces of wall preparatory to distempering, applying two coats of distemper oil emulsion, white or tinted, over 1 mm thick wall care putty all as specified and as directed
M&L for applying two coats of 100% anti fungal acrylic emulsion exterior grade paint (white & blue) (make Asian/Berger/Nerolac/Dulux) over a coat of acrylic primer in approved shade and as per manufactures instruction including necessary scaffolding etc complete and directed by Engineer-in-charge on newly plastered surfaces including preparation of surfaces on external surfaces (wall facia comices etc) by applying ready mix 'Birla White' white cement based wall care putty ( where required ) all as specified and as directed.
M&L for complete removal of any existing treatment by scrapping/rubbing & finally washing down with water and freeing the surface from all loose dirt, chalk, grease, fungi, algae, flakes,etc and making suitable for Apex painting on external surfaces (wall facia comices etc) and applying 2mm true care wall putty of ASIAN Paints/Equivalent and applying two coat of 100% ant fungous acrylic emulsion exterior grade paint (white & blue) (make Asian /Berger/ Nerolac/ Dulux) over a coat of acrylic primer in approved shade and as per manufactures instruction & including necessary scaffolding etc all as specified and as directed.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash all as specified and as directed.
M&L for preparation of new plaster surface of ceiling of any description and apply three coats of white wash all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position such as in plinth protection all as specified and as directed.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 using 40mm graded stone aggregate as in plinth protection all as specified and as directed.
M & L for sand filling in floors and proper levelling to required gradient and thickness all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
S & F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets all as specified and as directed.
M&L for appying two coats of painting with synthetic enamel paint on new steel surfaces of any description, not otherwise described, over 10cm width or girth including preparation of surfaces and priming with red oxide all as specified and as directed.
M&L for treating the existing surface of kota stone with grinding by machine including beewax polish all as specified and as directed.
Excavation in trenches not exceeding 1.5 deep and not exceeding 1.5 m wide in soft/disintegrated rock for foundations etc and getting out all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm in soft/disintegrated rock all as specified and as directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Demolition and breaking up of 150mm/160mm drain pipes (Salt glazed ware/AC/PVC) set in cement mortar all as specified and as directed.
Demolition and breaking up of 100mm drain pipes (Salt glazed ware/AC/PVC) set in cement mortar all as specified and as directed.
Demolition and breaking up of 75mm drain pipes (Salt glazed ware/AC/PVC) set in cement mortar all as specified and as directed.
M&L for concrete bed to drain pipe of 160mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete type C2 , 1:3:6 all as specified and as directed.
M&L PVC (SWR) pipes 160mms ingle socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
All as per Item No.107 here in before but for 110 mm dia all as specified and as directed.
All as per Item No. 107 here in before but for 75 mm dia all as specified and as directed.
Demolition of brick work or stone / boulder masonry built in cement mortar all as specified and as directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 using 20 mm graded stone aggregate with solid blocks exceeding 10 cm in width and set in cement mortar 1:6 complete except block all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surface, finished even and smooth using extra cement including mixing of water proofing compound at the rate of 3% by weight of cement or as per manufacturer's instructions for internal surfaces of manholes all as specified and as directed. Note:Water proofing compound shall be measured and paid separately.
M&L for providing cement concrete type B1, 1:2:4 using 20mm graded crushed stone aggregate in, copings, benching to manholes, water troughs and like including weathering slightly rounded or chamfered angles and throating, and including necessary form work complete all as specified and as directed.
M&L for pre cast cement concrete type B1,1:2:4 using 20mm graded crushed stone aggregates in cover slabs, set in cement mortar 1:4 with plain faces, complete all as specified and as directed Note: - Reinforcement steel shall be measured and paid separately under appropriate item of Schedule 'A'
M/S NAGINENI RANGA RAO
Raja Enterprises
Ramesh Enterprises
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
Super Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .