Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.6 L+₹2.6 L (43.2%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
6 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIRS TO 11 KV HT SUPPLY NETWORK AT 58 SU AF STATION CHIMNEY HILLS
2021_MES_495424_1
8488/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I AF CHIMNEY HILLS BANGALORE
₹12,000
Yes
25 Apr 2022
17 Dec 2021
8 Jan 2022
17 Dec 2021
6 Jan 2022
24 Dec 2021
17 Dec 2021 - 21 Dec 2021
60 days
Amount
Supply, jointing and testing out door type HT cable end termination joint "push on type" heat shrinkable suitable for aluminum conductor XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, and over all PVC sheathed cable 11000 volts grade 3 core 120 to 185 sqmm nominal size all as directed.
All as per item ser No 1 above here in before but indoor type joint
Supply, jointing and testing out door type HT cable end termination joint "straight through" heat shrinkable suitable for aluminum conductor XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, and over all PVC sheathed cable 11000 volts grade 3 core 120 to 185 sqmm nominal size all as directed.
Taking out the transformer oil sample from distribution/isolation transformers, indoor/outdoor type and testing the oil for dielectric strength/moisture content complete all as specified and directed by the Engr-in-Charge
Filtering the transformer oil having the dielectric strength below 40KV and testing of transformer oil after filtration as per IS-335-1972 and removing the moisture contents in the transformer cores/winding as directed by Engr-in-Charge.
Supply and filling top up new transformer oil in the transformer up to the marked level all as specified and directed by Engr-in-Charge.
Material and labour for lightning arresters for outdoor use expulsion type suitable for 11000 volts (HT) complete with all fittings, transmission class, discharge capacity 65 KA including taking down existing lightening arresters of any type and size complete all as specified and as directed.
Material and labour for fixing barrel fuse including fuse element suitable for HT 11 KV drop out fuse carrier up to 15 Amp rating all as directed after dismantling the exisiting out lived fuse barrel complete all as specified and as directed.
All as per item ser No 8 above here in before but upto 30 Amp
Material and labour for replacement of silica gel breather assembly for HT distribution transformers of 100 KVA to 750 KVA capacity including dismantling old one all as specified and as directed
Repair / service / overhauling of gang operating devices 11000volts upto 400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points, tightening all nuts and bolts and providing PG clamps, additional nut and bolts, commissioning and testing complete including dismantling and replacing all the unserviceable parts / spares all as specified and as directed. Note: Supply only of all the spares replaced shall be measured and paid separately.
Supply only moving contact blades
Supply only fixed contact jaw copper
Supply only Post insulator
Material and labour for pin type, porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for 11000 volts grade all as specified and as directed.
Material and labour for disc type, porcelain vitreous, 145 mm height and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified and as directed.
Dismantling insulators of any type and size complete all as specified and as directed.
Supply only for the Shunt trip coil 110 V DC/220 V DC /30 V DC suitable for upto 400 Amps 250 MVA to 450 MVA HT switch gear (OCBs/VCBs) and 11 KV HT panel repair work under above schedule items
Supply only the Spring charging motor suitable for upto 400 Amps 250 MVA to 450 MVA HT switch gear (OCBs/VCBs), 11 KV HT panel repair work under above schedule items, all as specified and directed.
Disconnection and taking out of the IDMT relay, three element type of any make or equivalent in model from HT panels consisting of the following :- (i) Cleaning of relay & contacts (ii) Calibration of relay by conducting secondary injection tests. (iii) Checking of CTs (iv) Rectification of defects in control wiring, if any (v) Adjustment/ setting of plug and time multiplier (vi) Setting of the relay to achieve the discrimination in tripping. (vii) Tuning of up stream breaks (viii) Re-installation of relays including testing.
Material & Labour for GOD / Switches air break ,Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps
Disconnection & Removing the unserviceable Aluminium conductor/jumper wires from the HT 4 Pole structure and M & L for New Aluminium overhead conductor jumpers sorrounded by PVC insulation sleeves with R,Y& B color code complete all as directed. Note : (1) All the jumper wires should be replaced with New jumper wires (2) Type of conductor used for jumper shhould be RABBIT. (3) Cost deemed to be include for all the misc work such as Nut,bolts, washers, welding etc. for satisfactory completion of job . (4) Min clearance should be maintained among the conductors as per the Electricity Regulations. (5) Zero percent Sag should be maintained for each jumper wire to avoid short ckts.
All as per item No.23 above but for 2 Pole structures
M/L for providing earthing complete with galvanised steel earth plate electrode 6o cm x 60 cm 6 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to galvanised earth strip 25 x4 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 5 of SSR Part I of 1991 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( Note1 :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ). Note 2: Qoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Dismantling and removing the u/s earthing from the 4 Pole/3Pole/2 Pole structure all as specified and as directed
devan enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .