Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.8 L
Closing Date
4 Nov 2019, 1:00 pmClosed
Joint Registrar
Joint Registrar, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi - 110007
General work for cleaning and disinfecting of drinking water tanks at VPCI
2019_DU_510862_1
MC/JE/Civil/eT-63(WTC)/19-20/
Open Tender
Civil Works
Works
60 days
Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹150
Yes
Director-VPCI
Exempted
7 Feb 2020
15 Oct 2019
5 Nov 2019
15 Oct 2019
4 Nov 2019
15 Oct 2019
15 Oct 2019 - 4 Nov 2019
Mechanized cleaning of underground & RCC/PVC OH tank with six stages process mentioned as under:- a)Mechanical Dewatering b) Desilting and removal of let over dirty water and sludge wit sludge removal pump. c) Cleaning of walls, ceiling and floor by high pressure water jet with the help of equipment which create a pressure of 100 to 150 bat with antibacterial agent license from food and drugs administration (FDA) and certificate by a govt. Approved laboratory for non-toxicity of antibacterial for tank cleaning as per OECD guidelines for disinfecting the tank from all harmful Bacteria, Fungi, Algae & Protozoan. The active ingredient shall be Benzalkonium chloride solution IP 4% W/V/Equivalent similar compound as per the directions & approved by the Engineer-in-charge. d) Removal of remaining sludge from the floor with the help of industrial vacuum cleaner. e) Spraying of non-toxic, bio degradable eco friendly antibacterial agent for tank cleaning certificate by Govt. Approved laboratory as per the OECD guidelines 423 adopted on 17th December, 2001 for disinfect the tank from all the harmful pathogens. f)Treatment of Inside the tank by exposing U.V Radiation to kill further suspended or floating bacteria if any. (1) 50000 Litres Capacity (UG Tank) - 07 nos.
Mechanized cleaning of underground & RCC/PVC OH tank with six stages process mentioned as under:- a)Mechanical Dewatering b) Desilting and removal of let over dirty water and sludge wit sludge removal pump. c) Cleaning of walls, ceiling and floor by high pressure water jet with the help of equipment which create a pressure of 100 to 150 bat with antibacterial agent license from food and drugs administration (FDA) and certificate by a govt. Approved laboratory for non-toxicity of antibacterial for tank cleaning as per OECD guidelines for disinfecting the tank from all harmful Bacteria, Fungi, Algae & Protozoan. The active ingredient shall be Benzalkonium chloride solution IP 4% W/V/Equivalent similar compound as per the directions & approved by the Engineer-in-charge. d) Removal of remaining sludge from the floor with the help of industrial vacuum cleaner. e) Spraying of non-toxic, bio degradable eco friendly antibacterial agent for tank cleaning certificate by Govt. Approved laboratory as per the OECD guidelines 423 adopted on 17th December, 2001 for disinfect the tank from all the harmful pathogens. f)Treatment of Inside the tank by exposing U.V Radiation to kill further suspended or floating bacteria if any. (2) 10000 Litres Capacity (UG at Patel Niwas) - 03 nos.
Mechanized cleaning of underground & RCC/PVC OH tank with six stages process mentioned as under:- a)Mechanical Dewatering b) Desilting and removal of let over dirty water and sludge wit sludge removal pump. c) Cleaning of walls, ceiling and floor by high pressure water jet with the help of equipment which create a pressure of 100 to 150 bat with antibacterial agent license from food and drugs administration (FDA) and certificate by a govt. Approved laboratory for non-toxicity of antibacterial for tank cleaning as per OECD guidelines for disinfecting the tank from all harmful Bacteria, Fungi, Algae & Protozoan. The active ingredient shall be Benzalkonium chloride solution IP 4% W/V/Equivalent similar compound as per the directions & approved by the Engineer-in-charge. d) Removal of remaining sludge from the floor with the help of industrial vacuum cleaner. e) Spraying of non-toxic, bio degradable eco friendly antibacterial agent for tank cleaning certificate by Govt. Approved laboratory as per the OECD guidelines 423 adopted on 17th December, 2001 for disinfect the tank from all the harmful pathogens. f)Treatment of Inside the tank by exposing U.V Radiation to kill further suspended or floating bacteria if any. (3) 2000 Litres Capacity (OHT) - 23 nos.
Mechanized cleaning of underground & RCC/PVC OH tank with six stages process mentioned as under:- a)Mechanical Dewatering b) Desilting and removal of let over dirty water and sludge wit sludge removal pump. c) Cleaning of walls, ceiling and floor by high pressure water jet with the help of equipment which create a pressure of 100 to 150 bat with antibacterial agent license from food and drugs administration (FDA) and certificate by a govt. Approved laboratory for non-toxicity of antibacterial for tank cleaning as per OECD guidelines for disinfecting the tank from all harmful Bacteria, Fungi, Algae & Protozoan. The active ingredient shall be Benzalkonium chloride solution IP 4% W/V/Equivalent similar compound as per the directions & approved by the Engineer-in-charge. d) Removal of remaining sludge from the floor with the help of industrial vacuum cleaner. e) Spraying of non-toxic, bio degradable eco friendly antibacterial agent for tank cleaning certificate by Govt. Approved laboratory as per the OECD guidelines 423 adopted on 17th December, 2001 for disinfect the tank from all the harmful pathogens. f)Treatment of Inside the tank by exposing U.V Radiation to kill further suspended or floating bacteria if any (4) 1000 Litres Capacity (OHT) - 98 nos.
Mechanized cleaning of underground & RCC/PVC OH tank with six stages process mentioned as under:- a)Mechanical Dewatering b) Desilting and removal of let over dirty water and sludge wit sludge removal pump. c) Cleaning of walls, ceiling and floor by high pressure water jet with the help of equipment which create a pressure of 100 to 150 bat with antibacterial agent license from food and drugs administration (FDA) and certificate by a govt. Approved laboratory for non-toxicity of antibacterial for tank cleaning as per OECD guidelines for disinfecting the tank from all harmful Bacteria, Fungi, Algae & Protozoan. The active ingredient shall be Benzalkonium chloride solution IP 4% W/V/Equivalent similar compound as per the directions & approved by the Engineer-in-charge. d) Removal of remaining sludge from the floor with the help of industrial vacuum cleaner. e) Spraying of non-toxic, bio degradable eco friendly antibacterial agent for tank cleaning certificate by Govt. Approved laboratory as per the OECD guidelines 423 adopted on 17th December, 2001 for disinfect the tank from all the harmful pathogens. f)Treatment of Inside the tank by exposing U.V Radiation to kill further suspended or floating bacteria if any (5) 500 Litres Capacity (OHT) - 71 nos.
Providing and fixing of synthetic sheet with gumming size 7” X 5” of required with date of cleaning written on them as directed by Engineer-in-charge.
Bharat Construction And Tank Cleaner
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .