Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being as lowest tender | |
| 2 | L2₹21.0 L+₹27,890 (1.35%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.2 L+₹56,755 (2.74%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) DELHI CANTT -10
GE (N) DELHI CANTT -10
REPAIR MAINT OF EXTRNAL ELECTRIC SUPPLY SYSTEM WITH CONNECTED WORKS AT OD SHAKURBASTI AND HIRAN KUDNA AREA UNDER GE NORTH DELHI CANTT-10
2020_MES_370577_2
GE/NORTH-46/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT -10
as per nit
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT -10
₹50,000
Yes
2 Nov 2020
19 Sept 2020
12 Oct 2020
19 Sept 2020
10 Oct 2020
26 Sept 2020
60 days
Amount
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil complete
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete
M & L for sand cushioning for proctection of cable with screen wash river sand complete
M&L for boring/ making hole under road by drilling machine or hand drill without damaging of road for laying U/G cable for size 40/50/80 mm bore of GI pipe complete all as specified & directed
M&L (in replacement) for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes :-
(a) 40 mm bore
(b) 50 mm bore
(c) 80 mm bore
Labour only for taking out and relaying/ re-routing old/existing PVC/XLPE armoured aluminium conductor cable after repair complete of following sizes (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :-
Upto size 25 sqmm 2/3.5/4 Core
Size 35 sqmm to 70 Sqmm 3.5 Core
Size 95 sqmm to 150 sqmm 3.5 core
Size 185 sqmm 3.5 core and above
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :-
(a) 10 Sqmm 2 core
(b) 16 Sqmm 4 core
(c) 35 Sqmm 3.5 core
(d) 50 sqmm 3.5 core
(e) 70 sqmm 3.5 core
(f) 95 sqmm 3.5 core
(g) 120 sqmm 3.5 core
(h) 185 sqmm 3.5 core
(j) 240 sqmm 3.5 core
Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete
Dismantling & taking out defective LT PVC/XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes :-
(a) 25 sqmm 3.5 core to 50 sqmm, 3.5 core
(b) 70 sqmm 3.5 core to 120 sqmm, 3.5 core
(c) 150 sqmm 3.5 core to 400 sqmm 3.5 core
S&F in repair of 1100 volt grade, heavy duty cable PVC insulated aluminium conductor, multistranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as directed
(a) 16 Sqmm, twin core, flat or circular
(b) 10 Sqmm, twin core, flat or circular
Checking all incoming & outgoing connections and Mechanism, cleaning, servicing, overhauling, testing it for proper tripping system complete of 11 KV VCB of Make Crompton Greaves/AREVA/Siemens, installed at sub-station bldg, inspecting, servicing and testing all the connections of control wiring availability of proper DC supply and AC supply, cleaning of contacts, & terminals, using the blower for dusting, servicing of gears, including replacement of faulty control fuses, faulty wiring & faulty indication lamp, checking & closing of tripping system, taking out relay (over current relay and earth fault relay) from the 11 KV VCB and calibrating the relay and proper setting of relay and refixing back in existing position & testing for proper tripping/functioning system complete all as specified & directed [Note : (i) Necessary certificate for calibration of relay with setting detail shall be submitted by the contractor. (ii) Spare parts will be measured and paid separately]
S&F charging handle rod suitable for existing 11 KV VCB 630 amps capacity of make Crompton Greaves/Areva/ABB/Siemens complete all as directed
S&F in repair Charging Motor assembly set in existing VCB panel of existing make incl all connections & fixing arrangement and testing complete all as directed
S&F in repair Spring charging gear assembly (big size) for VCB upto 630 Amp as per existing make of VCB complete all as directed
S&F in repair Spring charging gear assembly (small size) for VCB upto 630 Amp as per existing make of VCB complete all as directed
S&F in repair power pack unit suitable for 220 volts AC input & 110 volts DC output complete with 12 volts, 7 AH sealed lead acid batteries and suitable voltmeter etc suitable for operation of HT Panel complete all as specified and directed
S&F in repair Tripping coil assembly 24 V DC for VCB 11 KV as per existing make of VCB complete all as directed
S&F in repair Closing coil assembly 24 V DC for VCB 11 KV as per existing make complete all as directed
S&F in repair TNC switch (Trip Neutral Close), with 2 NO + 2 NC suitable LT/HT Panel any type/size as per existing complete all as directed (Make- As per sample of make Vaishno/Kaycee/AE/Siemens/Schneider/Rishabh)
S&F in repair heater, 230 Volt, as per existing wattage suitable for 11 KV HT VCB panel including electric connection complete all as specified & directed (Make - As per sample of)
Disconnection of all electric connection & taking out old/defective Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, comprising of 3 Nos single phase resin cast CTs of 100-50/5+5 amps ratio, Class 5P-10 with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection incl disconnection & taking out old/faulty current transformers (CTs) from 11 KV VCB panel complete all as specified & directed (Make-ABB/Crompton/Schneider/Siemens/Pactil/AE)
Disconnection of all electric connection and taking down defective/unsv 11 KV PT and Supply, fixing, installation & testing of Potential transformer (PT) 3 phase, dry and draw out type 11 KV/110 Volt, with suitable VA burden per phase, accuracy class 1.0 complete with HT & LT HRC fuses for primary & secondary in VCB complete all as specified & directed (Make-ABB/Crompton/Schneider/Siemens/Pactil/AE)
(i) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates.
(ii) The all above checking, inspection, installation & testing work shall be performed by HT expert/engineer.
M&L for on line Dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 50 to 60 KV breaking capacity by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as directed Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. (ii) Oil required for topping up the transformer will be measured & paid separately
M&L (in replacement) of Silica Gel (Blue colour) in breather of transformer after cleaning of breather
M&L (in replacement) of breather of transformer of any make/capacity upto 630 KVA with exising size
Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed (Make- Savita/apar/Powerlink/Powerzone/HP/arihant//zebron/apolo/indotech)
M&L for replacement of fibre gasket sheet 3 mm thick to prevent leakage from transformer 11/0.433 KV ratio, upto 630 KVA capacity complete
S&F in repair LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 630 KVA complete
S&F in repair HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 630 KVA complete
M&L for replacement of porcelain insulator with suitable rubber 'O' ring for HT side bushing of transformer upto 630 KVA complete
All as per item 33 above but for LT side bushing
M&L for painting of transformer of capacity upto 400 KVA, outside portion only with one coat with spray painting with synthetic enamel paint after preparation of surface neat and clean for painting including numbering SM/MES No. with white paint complete all as directed
M&L (in repair) cable jointing kit for 11 KV cable for end termination cold shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:-
(a) Size 70 sqmm to 95 sqmm, Indoor type
(b) Size 120 sqmm to 185 sqmm, Indoor type
(c) Size 70 sqmm to 95 sqmm, outdoor type
(d) Size 120 sqmm to 185 sqmm, outdoor type
M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified & directed of following size :-
(a) Size 70 sqmm to 95 sqmm
(b) Size 120 sqmm to 185 sqmm Note for item No 36 and 37 : Make - Raychem/Cabseal/M-Seal/Denson
Supply & laying in trenches/through pipes/ducts or on poles XLPE armoured cable of following sizes with aluminum conductor, 11 KV `E’ complete all as specified & directed of follwing sizes (Note :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :-
(a) 95 Sqmm 3 core
(b) 120 Sqmm 3 core
M&L for chequered plate 5mm thick of required size for cable duct cover as required at site incl cutting & welding including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed
Supply, installation, testing & commissioning (in replacement) of Gang operated air break switch with drop out fuse unit complete with 12 insulator set, HT 11 KV triple pole, 200 amps current rating complete with drop out fibre glass tube fuse, mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrengment, flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers incl jumper connection with copper flexible designed jumper complete all as specified and directed
Cutting/pruning of tree branches along/around over head line at places within a radius of 2 mtr from fasted conductor and removing from site complete all as directed
M&L for painting of steel tubular poles 9 mtr to 11 mtr length with applying two coats of aluminium paint including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and two coat for making colour band/strip 30 CM with synthetic enamel paint of approved/yellow & black colour up to 1.2 mtr from coping level including numbering of poles complete all as directed
M&L for painting of RCC poles 8.5 mtr to 11 mtr long with two coat of cement based paint and two coat of synthetic enamelled paint in yellow & black stip 30cm up to 1.5 mtr above the ground level including preparation of surfaces complete and painting of connected cross arms, clamps with aluminium paint all as specified and directed.
M&L for spray painting of old/existing LT panel/feeder piller box any size/type with powder coated paint withsmoke grey paint in outer/inner side of complete panel after cleaning and preparing surface complete all as specified & directed
M&L for replacement of door/MS sheet of old/existing LT panel board any type/size with cutting, welding & bend to shape and spray painting with powder coated paint with smoke grey paint in outer/inner side over one coat of primer after complete all as directed
M&L for replacement of lock assembly with key of old/existing LT panel board any type/size complete all as directed
M & L for repair/overhauling of old LT panel board of any size/type, cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning andpreparing surface incl sign writing complete all as directed
Supply, installation and connecting to electrical system in repair, LT distribution switch board panel cubical type for out door use, double door, with rigid hinges, door handles locking arrangement back side openable, compartmentalized design, mounted on suitable PCC blocks, fabricated out of CRCA sheet 3mm thick, suitably spaced, totally enclosed in chamber for reception of 3 phase, 440 V, 50 HZ, AC supply including all connection with aluminum strips, internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire with lugs. Panel shall be effectively PVC gasketed and sealed, glands to be provided at cable entries, powder coated painting and sign writing for in/out going connections all as specified & directed and comprising of following as under :-
(a) 4 Nos bus bars of high conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 400 amp rating and 1 No for neutral rating 200 amp, mounted on DMC support with heat shrink sleeve - 01 set.
(b) MCCB 4 pole, 250 amp, 415 volts, 25 KA - 01 No ( Incoming)
(c) MCCB 4 pole 125 amp, 415 volts, 16 KA - 04 Nos. (outgoing)
(d) MCCB 4 pole 63 amp, 415 volts, 25 KA - 01 No. (outgoing)
(e) MCB SPN 63 amp, 240 volts, 'C' series,10 KA - 02 Nos. (outgoing)
(f) Voltmeter (0-500V) digital type -01 No
(g) Ammeter (0-300 amps) digital type with CT's - 01 No
(h) Indication lamp (R,Y,B), LED type - One set of three
(j) Grouting of panel including PCC work (Note :- Make of MCCB/MCB - Schneider/ABB/L&T/Legrand)
Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system incl replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed (Note :- Spare parts will be measured and paid separately under respective item)
Supply only following item/spares for Air Circuit Breaker (ACB) :-
(a) Closing release of air circuit breaker
(b) Shunt release of air circuit breaker
(c) Under voltage release with time relay
S&F in repair Air Circuit Breaker (ACB) 630/800 Amp, 3 pole, 50 KA breaking capacity, 415 volt, electric drawout version, high short time fault withstanding capacity ICU=ICS=ICU for 1 second for total sensitivity, high mechanical and electrical operating life, protection through microprocessor release self diagnostic microprocessor based release with under voltage relay, short circuit relay, overload relay as per EMI/EMC standard with ON load testing through test button, inbuilt memory conforming to IS/IEC 60947-2 & IEC 60947-2 including making necessary arrangement/ hole in existing busbars for proper fixing of new ACB in existing frame of LT panel board and electric connection complete all as specified and directed (Make - Merlin Gerlin/Schneider/L&T/Havells/ABB/Siemens/Crompton)
S&F in repair 3 pole Power Contactor, MNX type of rating 32/40 amp AC3, closing coil 220 volt with auxiliary block (1 NO + 1 NC ) including electric connection in existing panel complete (Make- Hager/L&T /Siemens/Havell/Schneider)
S&F (in replacement) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 volts & 50 Hz system for permissible non- linear load 15% and connection in existing APFC panel complete of following capacity (Make-Schneider/L&T/Havells) :-
(a) 5 KVAR
(b) 10 KVAR
(c) 25 KVAR
M&L (in replacement) danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for HT/LT 20 x 15 cm size complete all as directed
S&F (in replacement) following items in the existing panel / location and connection with using aluminum lugs incl making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed :-
(a) MCB 4 pole 63 amps, 10 KA breaking capacity, B'' Series, 415 Volt
(b) MCB 4 pole 100 amps, 10 KA breaking capacity, B'' Series, 415 Volt
(c) MCCB 3 pole 63 amps, 16 KA breaking capacity, 415 Volt
(d) MCCB 3 Pole 100 amps, 16 KA breaking capacity, 415 Volt
(e) MCCB 3 Pole 125 amps, 25 KA breaking capacity, 415 Volt
(f) MCCB 4 Pole 200 amps, 25 KA breaking capacity, 415 Volt
(g) MCCB 4 Pole 250 amps, 35 KA breaking capacity, 415 Volt
(h) Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm
(j) Amp meter (0 to 300 amps) digital type, three phase of size 96mm x 96mm with suitable CTs
(k) Indicator lamp, LED type
(l) Multifunction Meter, digital type, three phase, size 80mm x 80mm, accuracy class 1.0 for monitoring of various electric parameters such as voltage, current, wattage, frequency, power factor etc. (Make : Schneider model No EM 6436H or equivalent in L&T/Siemens) Note :- (i) MCCB should be properly fited in existing compartment and operating handle of MCCB should be proper in opening existing cover/door of compartment of LT panel board. (ii) Make of MCCB/MCB/Contactor - Schneider/ABB/L&T/Legrand)
S&F (in replacement) lightning arrester, metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements, transmission class, discharge capacity 65 kilo amps, suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to earth wire 4mm dia GI with manufacturers test certificate complete all as specified & directed (Make : Rashtriya/Jaipuria Bros/OBLUM/GE Power/BHEL)
Transporting of serviceable transformer of capacity up to 630 KVA, ratio 11 KV / 0.433 from sub-station to any other sub station and mounting it in another sub station and making all necessary cable and earthing connections incl replacement of worn out nut & bolts as required and testing at site complete all as specified and directed.
S&F steel tubular electric pole, swaged, type 410 SP-31 (9 metre long) complete with CI base plate, bolts, nuts & screws all as specified including the following:-
(a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres.
(b) M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL
© M&L for Providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia
(d) M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands/strip 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above coping level
Dismantling and taking out unsv / damaged PCC pole any size/type complete
Taking down defective/damaged ACSR conductor of any size and supply, fixing and stringing ACSR conductor including provn of binding wire etc for LT distribution line and replacement of all wornout nut bolts and washers complete all as specified and directed.
Taking down defective/damage GI earth wire and supply, fixing and stringing of galvanised steel wire 4 mm dia for continuous earthing complete all as specified and directed
S&F (in replacement) pin insulator of 100 mm height, 65 mm dia for 1100 volt grade porcelain vitreous white brown or green including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut all as specified and directed.
Dismantling & taking down defective stay asembly and S&F stay assembly compring of 7/10 SWG galvanised stay stranded wire of reqd length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 16mm dia 180 cms, long stay rod with threded ends, GI nut & washers GI stay plate 230 x 230 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6mm flat iron loop insulator 90mm x 140mm dia, hole 25mm porcelain complete all as specified and shown in electrical plate No 1 of SSR Part I including cost of the following:-(a) Excavation in post holes in any type of soil, returning filling and well ramming including disposal of surplus soil to distance n.exc 50mtrs from starting points. (b) PCC (1:3:6) type C2, using 40mm graded stone aggregated as in foundation.
M&L in repair for cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed after dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / pole structures complete all as directed.
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete
M&L in repair for loop junction box, outdoor type, size 30cmx20cmX15cm, made out of engineering plastic one piece moulding type, bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colout, shock proof, rust proof, fire retardant, having front opening and locking arrangement with MCB SP 10 amps - 01 No, box duly fixed on the pole with flat iron clamp of size 25 mmX3mm with nuts & bolts complete all as specified and directed (Note : Cost of incoming& outgoing cable lugs & glands of suitable size deemed to be included in the quoted rate) (Make : Unilac / Universal Switch Gear Control / Sintex / Tricolite)
M&L (in replacement) for LED street/security light fittings 45 watt, made up of of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection, to be mounted on existing/ new GI bracket and connecting the street light fitting using 1.5 Sqmm PVC insulated copper cable complete all as directed. (Note - New GI bracket with clamp shall be measured & paid seperately) (Make of LED light fitting :- Havells/Philips/Wipro/GE)
All as above but LED light fitting 60 watt
All as above but LED light fitting 90 watt
M&L for LED Flood Light luminaire, energy saving & enviornmental friendly, long life diecast aluminium, IP65, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed for following wattage (Make : Havells/Philips/wipro/GE) :-
(a) 70 Watt
(b) 100 Watt
S&F (in replacement) LED Post top lantern luminaire 40 Watt, 5700 K, energy saving, environmental friendly, long life aesthetically designes with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source, clear acrylic cover, IP-65 incl connection using 1.5 Sqmm PVC insulated copper cable complete complete all as directed (Make: Havells/Philips/Wipro/GE)
S&F (in replacement) LED Landscape bollard light 10 watt , 230 volt, inverted pyramid tripod type with soft 360 deg light distribution, IP65 protection and fixed on existing foundation all as specified and directed [Make- crompton(LBLSN-10-CDL) or equivalent in Havells/GE/Wipro]
Checking & locating of fault in underground HT/LT cable of any size by cable fault locator machine complete all as directed
M&L for replacment of double compression stainless steel gland for power cable incl electric connection complete with new lugs/thimble complete all as directed (Make- Jainson/Dowell/Action/3M) of following sizes :-
(a) Size 22.9 mm dia suitable for 16 sqmm 4 core LT cable
(b) Size 28.9 mm dia suitable for 25 Sqmm 3.5/4 core LT cable
(c) Size 32.1 mm dia suitable for 35 to 50 sqmm 3.5/4 core LT cable
(d) Size 37.7 mm dia suitable for 70 sqmm 3.5/4 core LT cable
(e) Size 41.7 mm dia suitable for 95 sqmm 3.5/4 core LT cable
(f) Size 47.1 mm dia suitable for 120 sqmm 3.5/4 core LT cable
(g) Size 51.4 mm dia suitable for 150 sqmm 3.5/4 core LT cable
(h) Size 56.6 mm dia suitable for 185 sqmm 3.5/4 core LT cable
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
Supply & installation of display sign board, box type of size not less than 200cm x 150cm x 25cm with acrylic sheet cover in aluminium frame on front side and GI sheet on rear side and housing with LED light fitting 4 Nos of 20 watt for proper illumination incl necessary wiring arrangement & connection, display sign board should be marked with flow diagram of HT network with alumination sticker/ painting, fixing of board at wall with suitable fixing arrangement complete all as specified and directed
Supply of HT electric Rubber Mat sheet of size 1m x 2 m x 25 mm thick, ISI marked
All as item No 80 above but for LT 15 mm thick
Taking down defective street light fitting any wattage from pole and repair the same including replacement of defective/faulty LED driver and re-fixing the same incl connection complete all as directed
Schdule of Credit - 61060.00)
NEETU TRADERS (INDIA)
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .