Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.2 L+₹1.3 L (14.8%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.8 L+₹1.9 L (21.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹13.0 L+₹4.1 L (46.7%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
29 Oct 2020, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
REPAIR/ MAINTENANCE OF FIRE ALARM, FIRE HYDRANT SYSTEM AND CONNECTED WORKS POCKET I AND II AT CHAF BANGALORE
2020_MES_380094_1
87401CWEAFNBAN
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF BANGALORE
₹27,000
Yes
31 Dec 2020
23 Sept 2020
31 Oct 2020
23 Sept 2020
29 Oct 2020
16 Oct 2020
24 Sept 2020 - 3 Oct 2020
Amount
Excavating in trenches n.exc 1.5M wide and n.exc 1.5M depth for getting out for taking out/laying of UG cables in soft or loose soil complete all as specified and directed by Engineer-in-charge.
Returning filling in including spreading levelling watering well ramming in layers no exceeding 25 cm thick complete all as specified and directed by Engineer-in-charge.
Removal of excavated material not exceeding 50 mtr and depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and spread riddled earth soil is as permitted by IS1255 for cushioning top and bottom of the cable complete all as specified and directed by Engineer-in-charge.
Material and Labour Burnt bricks, sub class 'B' of designation 75, standard size laid in trenches as in protection of UG cables complete all as specified and directed by Engineer-in-charge.
Laying only Burnt bricks, sub class 'B' of designation 75, standard size as obtained against item No. 1 in trenches as in protection of UG cables complete all as specified and directed by Engineer-in-charge.
Taking down old u/s LT UG cable of any type any size complete all as specified and directed by Engineer-in-charge Note - Excavation shall be measured and paid separately under relevant item.
Material & Labour for LT UG Cable XLPE insulated , armored, heavy duty with multistranded aluminium conductor , 1100 volts grade , cross -sectional area 4 core x 25 Sqmm laid in trenches or fixed to walls/ poles or passing through pipes with and including lugs/ thimbles/ ferrules including connecting, testing complete all as specified and directed by Engineer-in-charge.
Material & Labour for LT UG Cable XLPE insulated , armored, heavy duty with multistranded aluminium conductor , 1100 volts grade , cross -sectional area 4 core x 16 Sqmm laid in trenches or fixed to walls/ poles or passing through pipes with and including lugs/ thimbles/ ferrules including connecting, testing complete all as specified and directed by Engineer-in-charge.
Taking down old un-serviceable GI tubing of any size complete all as specified and directed by Engineer-in-charge
Material & Labour GI tubing, medium grade, 50 mm bore, as in cable protection fixed to poles/walls or laid in trenches / under roads / crossing etc. fixed in repairs, all as specified and as directed Engineer-in-charge.
Material & Labour for Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of Adjustable Over load Bi-metalic thermal relay of size 20 to 32A , three phase 415V , fixed on existing fire pump starter panel and testing complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of single phase preventer suitable for 10/12.5 HP pump sets, connecting on existing starter panel complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of power contactor ,continous current rating 40A ,3 phase, 440V on existing fire pump control panel complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of push switch with NO/NC auxilary contacts, rated 230V 6A complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of LED indicator rated 230V , fixed in existing starter panel complete all as specified and directed Engineer-in-charge.
Material & Labour for Rewinding of motor up to 10 HP capacity with best quality new enameled copper winding wire of suitable gauge, providing insulating materials such as fibre glass, tape,varnishing ,heating up the assembling, including replacement of bearings/bushes by using hydraulic press, commissioning complete testing to full load all as specified and directed including dismantling & taking to work shop and bring back and fixing complete all as specified and directed Engineer-in-charge. Note : The motor to be issued to contractor to taken into workshop as and when necessary through gate pass duly signed by Garrison Engineer and enclose the same with RAR while claiming payments.
Material & Labour for Servicing of existing 6/8/10/12 zone fire alarm panel ,re-wiring defective connection, changing defective minor spare parts such as relays, connectors, electronic components etc and testing the panel on every zone complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement power supply transformer of rating 24V, 5 Amps,120 VA for fire alarm panel ,including fixing and connecting on existing control panel and testing complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement power supply SMPS of rating 24V, 5 Amps for fire alarm panel ,including fixing and connecting on existing control panel and testing complete all as specified and directed.
Supply & Fixing in replacement of rubber gasket for pipe flange/pump connections with exsiting suitable side complete all as specified and directed Engineer-in-charge.
Material & Labour for dismantling the existing centrifugal pump set (Terrace pump) from position by disconnecting the electrical connections and taking down the centrifugal pump set complete along with motor of capacity 10/12.5HP, 3 phase and transporting to workshop for servicing/overhauling and greasing, incl painting with two coats of synthetic enamel paint (Post box Red colour) and replace the following worn out parts, and reinstallation, testing and commissioning etc complete all as specified and directed Engineer-in-charge. (a) Bearings for Motor – 02 Nos. (b) Bearings for pump – 02 Nos. (c) Gland packing – 01 Set. (d) Bolts, nuts and washers – 01 Set.
Supply & Fixing in replacement of Gun Metal single way fire hydrant landing valve of size 63mm dia ISI marked with instantaneous coupling complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Gun Metal double way fire hydrant landing valve of size 63mm dia ISI marked with instantaneous coupling complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Gun Metal Bonate of size 63mm dia with spindle assembly ,Gland nut ,Operating CI Wheel for hydrant valve complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Gun Metal Coupling Assembly of size 63mm dia with Lug (Locking Pin) for hydrant valve all as specified and directed by Engineer-in-Charge
Supply & Fixing in replacement of Hydrant valve wheel of size 63mm dia complete all as specified and directed Engineer-in-charge.
Supply & Fixing of replacement of manual call point with glass cover and connected items complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of Fire Alarm sounders / electronic hooter / sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 dB to 120 dB measured at 1.5 Mtr with sound output variation of + 5 dB, 500 mtrs range with connected items complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of Automatic star delta starter panel for Terrace pump 12.5 HP 3 phase 415V, with MCB, Power Contact, OLR , Single phase preventer , timer with connected accessories and conecting the incomming and outgoing cables with proper lugs/glands etc , testing complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of pressure gauge of size 4" dia, 0-21 Kg/cm2 rating complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of sealed maintenace free lead acid battery of capacity 12V, 7/7.5AH battery, including connecting the wire with proper lugs,nuts bolts etc and testing the changing system to ensure the battery get charge complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of 63 mm dia, 15 mtr long rubberized fabric reinforced rubber lined canvas hose conforming to 15636-1988 including gun metal male & female instantaneous coupling hose and coupling conforming to IS 903-1975 all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of 20 mm dia, 30 mtr long rubber hose reel conforming to IS 444-1987 with gun metal nozzle complete all as specified and directed Engineer-in-charge.
Material & Labour for fabrication of fire hose cabinet box for keeping 2 No's hose pipe of size 63mm and length 15 meter each including branch pipe nozzle, coupling etcbox made up of MS sheet 800mm x 600mm x 250mm and thickness 2 mm with double leafed glazed shutters (glazed with 4mm thick glass) secured with rubber lining and locking arrangements including painting with 2 coats of synthetic enamel paint (post box red colour) over a coat of red oxide primer complete all as specified and directed Engineer-in-charge.
Material and Labour for fabrication of fire hose cabinet box for hose reel of size 20mm.and 30 meter length complete with coupling branch pipe and nozzle , MS sheet 450mm x 450mm 250mm. and thickness 2mm with double leafed glazed shutters (glaged with 4mm thick glass) secured with rubber lining and locking arrangements including painting with 2 coats of synthetic enamel paint (post box red colour) over a coat of red oxide primer complete all as specified and directed Engineer-in-charge.
Supply & Fixing hose reel drum suitable for 63 mm.dia and 15mtr length conforming to IS 884-1985 complete all as specified and directed Engineer-in-charge.
Supply & Fixing hose reel drum suitable for 20 mm.dia and 30 mtr length conforming to IS 884-1985 complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of brass nozzle 20mm dia and complete all connected items complete all as specified and directed Engineer-in-charge
Supply & Fixing in replacement of brass nozzle 63 mm dia and complete all connected items complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of MS sheet enclosure of 3.15mm thick for pump set of overall size 2.0m x 1.5m x 1.0m factory made with opening in both ends for entry exit for pipe with locking arrangements including two coats of synthetic enamel paint (post box red colour) over a coat of red oxide primer complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of GM gate valve of size 65mm dia after dismantling the existing union, nipple and cutting out rusted threaded portion and making new thread for inserting new GM gate valve (heavy duty) of ISI marked complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of GM gate valve of size 80mm dia after dismantling the existing union, nipple and cutting out rusted threaded portion and making new thread for inserting new GM gate valve (heavy duty) of ISI marked complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of foot valve CI with ISI marked heavy duty conforming to IS 4038 of rubber ball lock type including all accessories regular little rubber gasket, nut & bolts, washers etc complete of size 150mm dia complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of butterfly Valve 100 mm dia cast copper alloy screwed down high pressure with iron wheel screwed both sides for iron pipe confirming to IS 13095 and complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of butterfly Valve 80 mm dia cast copper alloy screwed down high pressure with iron wheel screwed both sides for iron pipe confirming to IS 13095 and complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of NRV sluice valve, 100 mm bore cast iron body with brass spindle, class-1 ISI marked, PN-1.6, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of NRV sluice valve, 80 mm bore cast iron body with brass spindle, class-1 ISI marked, PN-1.6, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of MS pipe carefully and supply, laying and connecting heavy grade ERW steel pipe of 100 mm NB, 6 mm thick as per IS 3589 (1981) including cutting / welding / grinding etc. and painting with two coats of synthetic enamel paint (post box red colour) over a coat of red oxide complete all as specified and directed Engineer-in-charge.
Refilling, Servicing and pressure Testing of ABC type Fire extinguisher of 04 Kg Capacity complete all as specified and directed Engineer-in-charge.
Refilling, Servicing and pressure Testing of CO2 type Fire extinguisher of 04 Kg Capacity complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of 1.5 Sq mm 4 core copper cable complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of 2.5 Sq mm 4 core copper cable complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of Fixing Two way Fire Brigade inlet connection adaptor complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of Water Tank inlet connection pipe made of MS pipe 100mm dia appx.1.5mm length vertical & 63mm dia MS pipe apprx 1metre length including 4 No 63mm dia outlet connection fabrication cutting, threading,welding,jointing,painting and making good to distrubed surface complete all as specified and directed Engineer-in-charge.
Material & Labour for cement concrete in foundations, filling and mass concrete (PCC) in CM of (1:2:4) with type B2 using 40mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of fire hook confirming to IS 927- 1981,hook head is made up of forged carbon steel duly painted with anti-corrosive paint, handle shall made of bamboo of length not less then 3 mtr, hook should marked with ISI marked complete all as specified and directed Engineer-in-charge.
Supply & Fixing in replacement of fire beater confirming to IS 8096-1992 ,beater blade is made out of steel wire mesh of size 452 x 352 mm. with fire resistant frame and handle is made out of solid bamboo of length 1.8 mtr, dia 30+ 5 mm. complete all as specified and directed Engineer-in-charge.
Material and Labour in replacement mild steel fire bucket confirming to IS 2546-1974, body made out of minimum 1 mm. Thickness, of capacity min 10 ltr and bucket is duly painted and marked as per fire standard complete all as specified and directed Engineer-in-charge.
Material & Labour for fabricating outdoor fire bucket stand made out off 50mm x 50mm x 6mm angle iron and MS sheet top roof made out of mimimum 3mm thickness for hanging 04 Nos of fire bucket and extingusher with proper foundation and placing the stand whenever specified by engineer -in-charge. including necessary welding ,cutting etc.and painting with post box red color complete all as specified and directed Engineer-in-charge.
Material and Labour for Painting of entire fire Hydrant system of each building with two coat of synthetic enamal red colour paint complete after scrubing,removing of old painted surface and preparing the surface.It also includes painting of electric panel and all marking with white colors,(valve pipeline,hydrants,tank,lid etc.) all as directed by Engineer-in- charge.Loc : P-226, P-227, P-228 ,P-229,P-265,P-231,P-230,Ankur Bldg,Airmen Mess,P-266,P-267,P-164,P-165,P-166, P167,P-223,P-224,P-225
Material and Labour for De-watering, removing all dirty, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead tanks (Fire tanks) by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank using synthetic enamel paint of white colour over black background with letters of size 50mm height x 50mm breadth for OH Fire tank upto 5000 litres capacity complete all as directed by Engineer-in- charge.
Material & Labour for testing of fire hydrant system of building at each floor by cheking serviceability of water pressure, hydrant valve, pumps, wheel, spindle assembly, Coupling , Assembly with Lug, canvas hose, MS pipe, brass nozzle, pressure gauge etc. complete all as directed by Engineer-in- charge.Note : The contractar shall maintain a register of seriviceability state of each fire hydrant system of each building and obtain a users signature (building inventory incharge), JE concerned and Engineer-in-charge. Note: 1. Item no 1 to 64 i.e motor or pumps or any connected items of fire fighting / fire alaram items become breakdown, the contractor shall locate the problem/fault at site within 24 hours on intimation by JE/Engineer-In-Charge and ensure that the fault rectified within 48 Hours on locating the fault, failing which an amount Rs 300.00 per hour will be recovered as penality from contractor dues after expiry of 48 hours 2. The firm is responsible all spares/items as applicable shall be purchased from original manufacturers/auth distributor/dealer only and GST vouchers shall submit to Deptt while claiming payments 3. The firm is responsible to carry out check of all the fire fighting/fire alaram system at least once in month to ensure serviceabilty and effectiveness of the complete system round the clock 24 X 7 for which a maintenance record/certificate duly signed by contractor and concerned JE E/M and Engineer-in-Charge seperately to be maintained. Note : The Engineer-in-charge is responsible to submit functional cert of fire alarm and fire hydrant system in respect of pocket I & II duly signed by users to Garrison Engineer for issuing of completion of the subject maint works.
Pacific Enterprises
B5BUILDING SOLUTIONS
GKR and CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .