| 1 | L1₹10.3 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.8 L+₹18,181.20 (1.72%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.3 L+₹73,331.70 (6.93%)Rejected-Finance 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
20 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF), BHISIANA, BATHINDA-151201
Replacement of double layer tinted glass of main ATC Tower at AF Stn Bhisiana
2020_MES_363527_1
GE/BHI-20/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹24,000
Yes
13 Oct 2020
23 Jul 2020
24 Aug 2020
23 Jul 2020
20 Aug 2020
6 Aug 2020
60 days
Amount
Taking down wooden/frames including glasses of any description, size, thickness at any height and removing to store complete all as specified.
M&L for complete removal of existing treatment including preparation of surfaces of wall and applying wall putty on plastered surfaces and two coats of oil bound distemper (OBD) complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on any faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for preparation of new plastered/unplastered or concrete/brick surfaces and other surfaces, applying two coats of oil bound distemper (OBD) with one coat of wall putty as in walls complete all as specified.
M&L for preparation of previousely treated or untreated concrete/plastered surfaces or any other surfaces of any description over 10 cm width or girth and applying two coats synthetic enamel paint complete all as specified and directed.
M&L for powder coated anodised aluminium frame for double layered tinted glass windows, ventilators with one or more rebates including joining cleat for fixing in slant slope outwards with RCC walls etc complete all as specified.
S&F powder coated air tight anodised aluminium sliding door shutters, aluminium section including necessary joining cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, railing, tower bolts, mortiselock etc complete all as specified.
S&F sound proof double layer 8mm thick clear toughened glass with 12mm air gap/vaccume pressure (8mm CTG + 12mm Air Gap + 8mm) with degree of clear visibility fixed with aluminium section for ATC at any height in single panel of each size 3.25 mtr width and 2.15 mtr height with slant slope of 15 degree, fixed with frame including all necessary fixing materials as per sample approved by user/GE complete all as specified. Note : Measurement of Double Layer Will be consider as Single Side.
M&L for excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface (soft/loose soil) complete all as specified and directed by Engr-in-Charge.
M&L for PCC type B-1, 1:2:4 (using 20mm graded stone aggregate) for foundation filling, mass concrete and etc complete all as specified and as directed.
S&F mild steel tube pipe (Hollow Section as Rectangular, Square, Circular etc) of medium grade for structural purpose as in column, purlins, rafters etc welded complete all as specified and as directed.
S&F MS plates (Plain or chequered) channels, square cut or notched (Ordinay and counter sunk) forming holes, without any attachment with riveted, bolted or welded complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or grith and applying two coats of synthetic enamel paint over a cost of red oxide primer over new surfaces complete all as specified and as directed.
M&L for cutting opening in cement concrete walls (where reinforcement is also cut through & any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to received rendering etc complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars but excluding ashlar facing dressed stone and removing the rubbish out side MD land complete all as specified and as directed.
M&L brick work sub class 'B' brick old size bricks straight or curved on plain exceeding 6 mtr mean radius built in CM 1:6.
S&F LED security light fitting 45 watt high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia (as per requirement) GI pipe medium grade 1.5 mtr long bent to shape and fixed on wall with flat iron clamp, but, bolts washer etc all as specified and directed by Engr-in-Charge. Note : (a) Make of Luminaire and Driver shall be same. (b) CRI of luminaire should be more than 80%. (c) Lumen afficacy shall be minimum 100 lumens/watt. (d) THD shall be less than 20%. (e) P.F. shall be minimum 0.90. (f) LM 79 & LM 80 report for fixture & LED shall be produced by the Contractor.
M&L for conduit point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated and sheathed cable 1100 Volts grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 19/20/25 mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisioning of 1.5 Sqmm PVC insulated sheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the folling:
One Light point controlled by one switch 5/6 Amp one way.
M&L switch piano flush type single pole, one way 6 Amp.
M&L for submain wiring with two single core of 2.5 Sqmm and one single core of 1.5 Sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 Volts grade drawn through in PVC conduit (ISI marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubbed surface to match the existing surface.
M/s Vee Kay Associates
M/s Kamal Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .