Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.2 LAccepted-Finance | L-1 | Accepted-Finance Admitted | |
| 2 | L-2₹9.4 L+₹1.2 L (14.1%)Accepted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L-2 | Accepted-Finance Admitted |
Tender Value
₹9.9 L
EMD Value
₹10,000
Closing Date
9 Jun 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle Pathrahiya Road, Mirzapur
Construction of 132 KV and 33 KV Transformer bay for 40 MVA T/F at 220/132/33 KV S/S Mirzapur under ETD, Mirzapur
2021_UPTCL_584006_1
01/2021-22/ETC/Mzp
Open Tender
Electrical Works
Fixed-rate
60 days
Mirzapur
as per tender specification
2 documents required · 2 mandatory
₹1,180
Executive Engineer, ETD, Mirzapur
₹10,000
23 Jun 2021
22 Apr 2021
10 Jun 2021
23 Apr 2021
9 Jun 2021
23 Apr 2021
180 days
Amount
DESCRIPTION OF MATERIAL
Bolted type single tension fitting along with 5 G.I.U bolt suitable for ACSR Zebra conductor
Single Suspension fitting made of LM-06 Aluminium alloy suitable for ACSR Zebra conductor
Single Pilot Suspension fitting made of LM-06 Aluminium alloy suitable for ACSR Zebra conductor
PG Clamp made of LM-06 Aluminium alloy alongwith four galvanised nut & bolts suitable for ACSR Zebra to Zebra conductor.
PG Clamp made of LM-06 Aluminium alloy alongwith four galvanised nut & bolts suitable for ACSR Tarantulla to Zebra conductor.
PG Clamp made of LM-06 Aluminium alloy alongwith four galvanised nut & bolts suitable for ACSR Moose to Zebra conductor.
PI Clamp made of LM-06 Aluminium alloy alongwith four galvanised nut & bolts suitable for ACSR Zebra conductor.
220KV 70KN Composite silicon Rubber Polymer Insulator with Grading Rings
132KV 70KN Composite silicon Rubber Polymer Insulator with Grading Rings
75x10 mm MS Flat
50x6 mm MS Flat
DESCRIPTION OF WORKS
Complete installation, commissioning & cable connection of following equipments as per instruction mannual of various equipments and technical specifications of UPPTCL including shifting of materials/equipments from store to erection site and including all other associated work to complete the job.
Circuit breaker
132 KV SF6 Circuit Breaker
33 KV Vaccum Circuit Breaker
Current Transformer
132 KV Current Transformers
33 KV Current Transformers
132 KV CT Juction Boxes
33 KV CT Juction Boxes
Bus Isolators
132 KV Bus Isolators Without E/S
33 KV Bus Isolators Without E/S
Tendom Isolators
132 KV Tandem Isolators with post insulator
Post Insulators for support
132 KV Post Insulators
Surge Arrestors
132 KV Surge Arrestors
33 KV Surge Arrestors
132/33 KV T/F control & Protection panel SAS based
Laying of following sizes of control cable in cable trench from various equipments to control panel/ Junction box with proper dressing and saddling of cable at every 75 mm distance with MS Saddle of size 25x3 mm including carriage of cable drums from store to site and shifting back to store and fixing of cable tray as per cable schedule as per lay out and technical specifications of UPPTCL and all other associated work to complete the job.
2 Core X 2.5 Sq .mm
4 Core X 2.5 Sq .mm
6 Core X 2.5 Sq .mm
10 Core X 2.5 Sq .mm
For construction of 132 KV & 33 KV bay termination of all Control Cable as per cable schedule including making necessary hole in gland required. Supply and fixing of suitable cable gland of appropriate size, supply and providing ferrules in each core of cable and its termination with Lugs and all other associated work to complete the job.
Erection of Lattice Type main and Auxillary Structures (ATMS-05 set,AXM-08 set,ALP-11 set, BCT-03 set,BBL-02 set,ABL-01 set,BTI-01 set, XMM-05 set,YPM-05 set) including shorting , shifting ,Cutting , bending ,matching of hole where necessary ,streightening and other associated work to complete the job. As per technical specifications of UPPTCL including shifting of materials/equipments from store to erection site and including all other associated work to complete the job.
Stringing of Jack bus bar upto 36 mtr. long 3-phase above 132 KV main & Transfer bus with Zebra conductor including fixing of 120/70 KN Disc insulator/Tension/suspension fitting/ PG Clamp etc. Cutting of conductor and also shifting of all material from store to site of work and all other associated work to complete the job satisfactory.
Stringing of Jack bus bar upto 24 mtr. long 3-phase (in three sections) from 132 KV main bus to newly erected BTM Gantry with Zebra conductor including fixing of 120/70 KN Disc insulator/Tension/suspension fitting /PG Clamp etc.Cutting of conductor and also shifting of all material from store to site of work and all other associated work to complete the job satisfactory.
In newly constructed 132 KV & 33 KV bay proper Earthing of various Equiptment by MS Flat of following size including painting with standard quality primer then two coat of green paint.
75 x 10 mm MS Flat
50 x 6 mm MS Flat
Bay wise interconnection of equipments with Zebra conductor (jumpering) of 132 KV feeder bay.
Jumpering between Main bus to BSI including PG clamp.
Jumpering between BSI to Jack bus including fixing of 120/70 KN Disc insulator/Tension/Suspension fitting/ PG Clamp etc.
Jumpering between CB to Jack bus including fixing of 120/70 KN Disc insulator/Tension/Suspension fitting/ PG Clamp etc.
Jumpering between CB to LSI.
Jumpering between LSI to CT across Tandom isolator including PI/PG/Isolator clamp.
Jumpering (dropper ) between Transfer bus to tandem isolator including PG clamp.
Jumpering (dropper) for LA making Y-Shape from jack bus by PG clamp.
Jumpering (dropper) for T/F HV making Y-Shape from jack bus by PG clamp.
Jumpering (dropper ) for CT including fixing of 120/70 KN Disc insulator/Suspention fitting/ PG/CT Clamp etc. .
Jumpering (dropper ) between jack bus to Transfer bus including PG clamp.
Bay wise interconnection of equipments with Zebra conductor (jumpering) of 33 KV bay.
Jumpering between T/F LV to CT across LA.
Jumpering between CT to CB.
Jumpering between BSI to 33 KV Main bus.
Earthing of 132 KV & 33 KV LA consisting of 40 mm dia,3 meter long Electrodes which is to be febricated and piercing inside the ground and connecting all the electrodes with 75x10 mm MS Flat below 700 mm from ground level including excavation, back filling and levelling of earth.
Dismentaling, shifting , erection and re-connection of all cable as usual in LDB no-2 & 3 at 132 KV side after pulling/dragging or re-laying of fresh cable if found short and re-termination of control/power cable as per requirement for satisfactory completion of work.
Erection of all three phases 132 KV post insulators upon Upper AXM beam (at height of 12 meter) for maintaining clearance from jumpering of T/F Jack bus to Lower AXM beam (at height of 8 meter) by making platform for post insulator including fabrication of AXM beam, Cutting, Drilling,applying Zinc rich Alluminium paint on effected area (only old tower parts shall be provided by UPPTCL, if required).
Hi-tech power transmission
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .