EE( Elec plng and Tender)
BSNL EC-II, Kellys, Chennai
EA set repairs and reinstallation works in GSM North OA
2025_BSNL_222810_1
NIT No. 01 / EE-T/EC-II/CH/2024-25
Open Tender
Electrical Works
Works
60 days
various BTS stations in North BA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
BSNL Chennai telephones
₹49,034
Yes
18 Feb 2025
4 Jan 2025
15 Jan 2025
4 Jan 2025
14 Jan 2025
4 Jan 2025
4 Jan 2025 - 14 Jan 2025
Identifying the faults & parts to be replaced for the existing 15 KVA E/A set i/c arranging the skilled / semiskilled labourer to the site, Cleaning the E/A set , removing the dust, Arranging the suitable capacity Lead Acid Battery on rental basis for kick starting the E/A set and diesel of sufficient quantity in a separate container with diesel hoses for temporary connection and pumping the diesel to the Engine Fuel pump etc .i/c attending very minor faults if any relevant to the E/A set etc as reqd.
Oil servicing the existing 15 KVA Air cooled E/A set comprising of replacement of suitable luboil filter, diesel filter,air filter, lub oil of required quantity, radiator coolent in case of water cooled EA sets etc i/c removing and disposing off old oil/coolant, filters etc complete as required.
Providing and fixing of following items in the existing EA set i/c removing the wornout items , deassembling / assembling , testing and commissioning etc as reqd
i)Dynamo/Radiator belts
ii)Diesel Hose including banjo bolt and clip
iii)Radiator fan /blower bearing pulley assembly
iv)LLOP Sensor switch
v)Oil inlet breather hose arrangement
Servicing the Radiator of 15KVA Engine including dismantling, transportation, servicing, fixing, testing etc. as required.
Servicing of the faulty Fuel injection pump of the 15KVA EA set by disconnecting from the Engine and taking to workshop and bringing back to site after rectification of fault and fixing in the Engine and testing, commissioning etc as reqd.
Servicing the existing self motor of 15KVA Engine including dismantling, transportation, servicing, fixing, testing etc. as required.
Providing and Fixing self motor suitable for the existing 15KVA Engine including dismantling, transportation, servicing, fixing, testing etc. as required.
Replacing the battery lead cable of suitable size for the existing 88AH Battery ( Pre-terminated with copper lugs with insulation between Battery and E/A set i/c giving connections etc as reqd ( 2 Nos of 1 mtr length - 1 set )
Providing and Fixing 12volt/10 A Capacity Battery Charger suitable for the existing 15KVA Engine including dismantling, transportation, servicing, fixing, testing etc. as required.
Supplying and Fixing of AVR in the Alternator including giving connections,testing and commissioning etc as reqd
Supplying and fixing of following items in the existing EA set - Alternator & Control Panel i/c making connections , testing and commissioning etc etc as reqd
i) Push buttons
ii)Contactor coil for GE make Model CL07 3POLE
iii) LED - Indication Lamps
Attending the following faults/ replacement of worn out items in the existing E/A set Canopy door etc as reqd
Replacement of EA set Door hinges-(1 Set- 5 Nos doors,10 Hinges)
Replacement of Door Lock set - 1 nos each for 5 doors
Replacement of net type mesh sheet made of Aluminium to cover the glass wool for the sound proof arrangement etc as reqd
Painting the existing 15 KVA set canopy basechannel, exhaust pipe line & Silencer , Doors & MS supporting arrangements inside the canopy etc as reqd
Conducting load test for the existing 15 KVA E/A set with available load for 20 Minutes i/c topping up of diesel for testing ( approx : 20 Ltrs) Checking the general operations of E/A set such as monitoring the electrical parameters, taking the readings , observing any abnormal sound / vibrations / oil/diesel leakage etc.
Attending minor fault in EA set control panel with suitable spares i/c modifications in the wiring and testing etc complete as required
Replacement of complete AMF/Manual control panel suitable for 15 KVA EA set complete with all required switch gears , controllers ete as required
Shifting and reinstallation of EA sets from standalone BTS sites to HUB/Sharing/Super critical sites in the following specified location / Floor / Terrace of the building ( Upto to 3 rd Floor Terrace) etc i/c transportation ( Approx Distance upto 50 Kms ), Dismantling with suitable tools & skilled manpower etc., complete as required
Ground Floor of the existing site to Ground floor of the New site
Terrace of the existing site to Ground Floor of New site
Ground Floor of the existing site to Terrace of the New site
Terrace of the existing site to Terrace of New site
Supplying and Fixing the 12V,88 AH Heavy duty lead acid Battery i/c mounting on the existing stand ,giving connections , testing and commissioning etc as reqd
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .