Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.1 LAccepted-AOC | 1 | Accepted-AOC awarded | |
| 2 | 2₹22.9 L+₹8,250 (0.36%)Rejected-Finance | 2 | Rejected-Finance high bidder | |
| 3 | 3₹23.3 L+₹51,333 (2.25%)Rejected-Finance | 3 | Rejected-Finance highh bidder |
Tender Value
₹20.3 L
EMD Value
₹40,600
Closing Date
12 Apr 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
CANAL DIVISION FARIDKOT
Reconstruction of Bridge at RD 39360 of Sibian Disty
2023_WR_98366_1
Reconstruction of Bridge at RD 39360 of Sibian Dis
Open Tender
Civil Works - Canal
Item Rate
90 days
GHOLIA
Qualification Details
2 documents required · 2 mandatory
₹5,000
Yes
₹40,600
Yes
Faridkot
19 Jul 2024
7 Mar 2023
13 Apr 2023
7 Mar 2023
12 Apr 2023
7 Mar 2023
9 Mar 2023
Amount
Dismanteling of old bridge CC 1:4:8
Dismanteling of old bridge Brickwork
Dismanteling of old bridge RCC
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (Depth upto 3 m)
PCC 1:3:6 (M-10) nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by viberation i/c curing for 14 days as per drawing and technical specification.
PCC 1:3:6 (M-15) nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by viberation i/c curing for 14 days as per drawing and technical specification.
Laying RCC M-30 with using batching plant, transit mixer and concrete pump in Sub structure, complete as per drawing and Technical specifications. (Height upto 5 m)
Laying Reinforced cement concrete (M-25) with using batching plant, transit mixer and concrete pump in Sub structure, complete as per drawing and Technical specifications. (Height upto 5 m)
Laying RCC M-30 for solid slab superstructure using batching plant, Transit mixer and concrete pump including cenetering & shuttering laid in position complete in all respects. (upto 5 m height)
Providing and fixing drainage spout complete as per drawing and Technical specification.
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe-500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete. (Foundation & sub structure)
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe-500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete. (Super structure)
Providing weep holes in brick masonry/Reinforced concrete abutment, wing wall/return wall with 100 dia PVC pipe,
Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ 1 Litre for 2 sqm.
Cautionary sign board 600 x 600 x 600 mm triangular as per IRC 67 - 2012 with high intensity microprismatic grade retro reflective sheeting as per ASTM D 4956-09 and as per IRC 67-2012 fixed over 3mm thick aluminium composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both side and fixing the same with suitable size aluminium alloy rivets @ 200 mm C/C to badck support frame of 25 x 25 x 3 mm angle iron frame supported on square hollow steel saction post 60 x 60 x 3.2 mm Conforming to IS 4923 without cost of definition platge firmlyh fixed to ground in foundation concrete M-25 of size 0.45*0.45*0.60 m for vertical post complete as per clause 801 of MORT&H specification supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retero reflective sheeting & a certifide copy of test reports from an independent test laboratory conforming to Clause 6.7 of IRC 67-2012 Using high intensity Microprismatic grade retro reflective sheeting type X1 as per ASTM D 4956 09 and as per IRC 367 2012
Mandatory sign board 600*600*600 mm circular as per IRC 67 - 2012 with high intensity microprismatic grade retro reflective sheeting as per ASTM D 4956-09 and as per IRC 67-2012 fixed over 3mm thick aluminium composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both side and fixing the same with suitable size aluminium alloy rivets @ 200 mm C/C to back support frame of 25 x 25 x 3 mm angle iron frame supported on square hollow steel saction post 60 x 60 x 3.2 mm Conforming to IS 4923 without cost of definition platge firmlyh fixed to ground in foundation concrete M-25 of size 0.45*0.45*0.60 m for vertical post complete as per clause 801 of MORT&H specification supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retero reflective sheeting & a certifide copy of test reports from an independent test laboratory conforming to Clause 6.7 of IRC 67-2012 Using high intensity Microprismatic grade retro reflective sheeting type X1 as per ASTM D 4956 09 and as per IRC 367 2012
Informatory sign board 600 x 600*600mm squareas per IRC 67 - 2012 with high intensity microprismatic grade retro reflective sheeting as per ASTM D 4956-09 and as per IRC 67-2012 fixed over 3mm thick aluminium composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both side and fixing the same with suitable size aluminium alloy rivets @ 200 mm C/C to badck support frame of 25 x 25 x 3 mm angle iron frame supported on square hollow steel saction post 60 x 60 x 3.2 mm Conforming to IS 4923 without cost of definition platge firmlyh fixed to ground in foundation concrete M-25 of size 0.45*0.45*0.60 m for vertical post complete as per clause 801 of MORT&H specification supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retero reflective sheeting & a certifide copy of test reports from an independent test laboratory conforming to Clause 6.7 of IRC 67-2012 Using high intensity Microprismatic grade retro reflective sheeting type X1 as per ASTM D 4956 09 and as per IRC 367 2012
Hazard maker sign board 300 x 900 mm rectangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Providing and fixing tar paper bearing on abutment cap rubbed smooth.
Providing and filling joint sealing compound as per drawing and Technical specifications.
Providing fitting and fixing mile steel railing complete as per drawing and technical specifications
Provision of an Reinforced cement concrete crash barrier at the edges of the Bridge,road, approaches to bridge structures and medians, constructed with M-40 grade concrete using cement , as per dimensions in the PWD stanadard drawing No 7.Section 3,Including form work but excluding steel reinforcement-and at locations directed by the Engineer, all as specified-with concrete mixture.
Any other Item
THE GIDDERBAHA CO OP L and C SOCIETY LTD.
THE GORAN GATE CO OP L AND C SOCIETY LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .