Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹3.8 L+₹14,768.34 (4.09%)Rejected-Finance V P O SANGHOLE TEH JAISINGHPUR DISTT KANGRA H P | MANDI | HIMACHAL PRADESH | 175013 | L2 | Rejected-Finance Highest |
Tender Value
₹3.6 L
EMD Value
₹8,000
Closing Date
16 Apr 2021, 5:00 pmClosed
Amit Manuja
Executive Engineer, Provincial Division No.1, PWD B and R, Kurukshetra
Special repair /Renovation of Sub Health Centre at village Bhagthala in District Kurukshetra (under Health Wellness Centre Scheme) (Excluding EI)
2021_HRY_166282_2
PWD/AMB/KKR-1/110125
Open Tender
Construction Works
Works
60 days
Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹8,000
4 Dec 2021
10 Apr 2021
19 Apr 2021
10 Apr 2021
16 Apr 2021
10 Apr 2021
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)
Excavation of trenches in street lanes or in open areas for sewer, running by gravity and man holes to full depth as shown in drawing in cluding shoring, timbering of the poling boards frame system type and removal of surplus soil from site of work, upto a lead of 1 km in ordinary soil for depth of excavation not excceding 3.00 mtrs below ground level. [HSR 6.10(a)].
Scraping white wash and colour wash (HSR 8.32) (a)
Cement concrete 1:8:16 with stone aggregate 20mm nominal size in foundatin & plinth (HSR 10.29)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation & plinth. (HSR 10.39)
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)].
First class brick work laid in cement sand mortar 1:6 in foundation and plinth . (HSR 11.2)
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. Make:- Supreme, Finolex or Prince. [HSR 13.89].(a) 100 mm dia PVC pipe 6 kg. pressure.
12 mm thick cement Plaster 1:4. (HSR 15.5)
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall (HSR 15.10)
Applying pink primer or aluminum priming coat on wood work including preparation of surface, Knotting and stopping etc. + Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.2+16.3)
Distempering with washable oil bound distemper (of approved manufacture ) two coats over one priming coats on new work. (HSR 16.58)
Providing two coats of exterior acrylic emulsion paint. 2nd Quality (HSR 16.79) (a)
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (JK/Birla Make) (HSR 16.81)
Wire gauze commercial hard wood such as hollock, champ, chikrassy etc. (non-coniferous timber other than teak conforming to I.S. specification No. 1003 kiln seasoned) door and window shutters without springs housed in chowkats including chocks, iron hinges and screws, etc., complete fixed in position (excluding the cost of tower bolts and handles but including the labour for fixing the same). 30 mm thick (HSR 17.31) (i)
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ,chikrassy and chaplash,etc.,(non-coniferous timber other than teak,conforming to I.S.specification No.1003,kiln-seasoned),with 100 mm wide verticle styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges,screws,chocks/cleats,stops,nails etc., complete,fixed in position (excluding the cost of any fittings,other than specified above,but including labour for fixing the same in position). 30 mm thick (HSR 17.90) (i)
Factory manufactured solid flush door shutters, with block board core as per I.S.No.1659- 1969 bonded with water proof type phenol formaldehyde synthetic resin,hot- pressesd, conforming to I.S.2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc.(excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- (a) commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges.) 35 mm thick (HSR 17.93)
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22 )
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete: -door and window frame size 127 mm X 50 mm with 40 mm wide double rebate (HSR 18.34) (C)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: (HSR 28.50) (a) Filter media fine graded 1.5 mm to 3 mm 1 x 3.2 x 1.6 x 0.5 = 2.56 cum
Filter media course sand 3 mm to 6 mm 1 x 3.2 x 1.6 x 0.5 = 2.56 cum
Filter media course Bajri 6 mm to 20 mm 1 x 3.2 x 1.6 x 0.5 = 2.56 cum
(d) Filter media boulders 50 mm to 75 mm 1 x 3.2 x 1.6 x 1.0 = 5.12 cum
Constructing brick masonary inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cenent concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1mm thichk of neat cement RCC 1:2:4 slab 100 mm thick/c.C topping 50mm thick with 455mm x 455mm/455mmx610mm inide light duly C.I inspection chamber cover and frame weight as per ISI specification painted with 3 coats of black bitumastic superior paint complete as per standred design. (HSR 29.84) (a) Size 450 mm x 450 mm inside
Size 600 mm x 900 mm inside
Extra for over 0.30 metre depth of inspection chamber. (HSR 29.85) (a) 450 x 450 mm
Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (a) 200 mm dia (RCC NP2). (HSR 29.93).
Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. Type: Extra heavy duty set (MD-10) 560 mm clear opening. (HSR 29.94)
Providing & fixing PVC pipe (10kg/cm2) duly slotted IS-4985:1988 including cost of adhesive, carriage, loading, unloading,Filter mesh etc. complete in all respects to the satisfaction engineer incharge. Make:- Supreme, Diplast or any reputed make as approved by Engineer-Charge. (i) 160 mm i/d (NS)
Boring for hand-pump in clay, fitting strainer and pipe (b) above 160 mm dia bore, but not exceeding 300 mm dia (i) from 0 to 100 meter. [N S].
rajinder kumar govt contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .