| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹43.2 L+₹7.3 L (20.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.4 L+₹8.5 L (23.6%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | VEE KAY ENTERPRISES L2 | Charan sales and Service L3 | santosh electronics L1 |
|---|---|---|---|---|---|---|
| 1.00 | Complete general servicing of DG set of Capacity :- 5 KVA to 63 KVA of any make which include taking down and replacement / repairs of diesel filter, oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, gaskets, burnt parts & measuring earth resistance values (as required) etc. and tightening of nuts, bolts, washers, greasing, etc for proper running of DG Sets complete all as specified and directed.
Note for Ser No 1 to 5:-
(i) Cost of fixing charges, oiling, greasing, labour only replacement of engine oil etc. tightening of nuts, bolts and minor work extra are included in the unit rate quoted by the contractor.
(ii) Maintenance of Diesel Generating Sets will be carried out and Maintenance records shall be prepared by Contractor and signed by JE E/M & Engineer-in-Charge. All Maintenance register will be provided by the Contractor for record purpose.
(iii) The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other taken down unserviceable parts/spares shall be replaced and paid under relevant item of BOQ | 20 | Each Job | 500 ₹10,000 Lowest | 2,000 ₹40,000 | 1,890 ₹37,800 |
| 2.00 | All as per serial item No 1.00 above but capacity of DG Set 75 KVA to 100 KVA complete all as specified and directed. | 8 | Each Job | 500 ₹4,000 Lowest | 3,000 ₹24,000 | 3,000 ₹24,000 |
| 3.00 | All as per serial item No 1.00 above but capacity of DG Set 125 KVA to 250 KVA complete all as specified and directed. | 10 | Each Job | 500 ₹5,000 Lowest | 3,000 ₹30,000 | 4,000 ₹40,000 |
| 4.00 | All as per serial item No 1.00 above but capacity of DG set 320 KVA complete all as specified and directed. | 7 | Each Job | 500 ₹3,500 Lowest | 5,000 ₹35,000 | 5,000 ₹35,000 |
| 5.00 | All as per serial item No 1.00 above but capacity of DG set 500 KVA complete all as specified and directed. | 5 | Each Job | 500 ₹2,500 Lowest | 5,000 ₹25,000 | 6,000 ₹30,000 |
| 6.00 | Supply only Diesel filter for DG Set of following capacity capacity :- 5 KVA - 62.5 KVA | 20 | Each | 250 ₹5,000 Lowest | 500 ₹10,000 | 750 ₹15,000 |
| 6.10 | Supply only Diesel filter for DG Set of following capacity capacity :- 75 KVA to 250 KVA | 18 | Each | 250 ₹4,500 Lowest | 700 ₹12,600 | 1,200 ₹21,600 |
| 6.20 | Supply only Diesel filter for DG Set of following capacity capacity :- 320 KVA to 500 KVA | 12 | Each | 250 ₹3,000 Lowest | 2,000 ₹24,000 | 2,500 ₹30,000 |
| 7.00 | Supply only Lube filter for DG Set of following capacity:- 5 KVA to 62.5 KVA | 20 | Each | 250 ₹5,000 Lowest | 500 ₹10,000 | 750 ₹15,000 |
| 7.10 | Supply only Lube filter for DG Set of following capacity:- 75 KVA to 250 KVA | 18 | Each | 250 ₹4,500 Lowest | 700 ₹12,600 | 1,200 ₹21,600 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
14 Feb 2026, 6:00 pmClosed
GE(AF)EM Chakeri Kanpur
GE(AF)EM Chakeri Kanpur
COMPEREHENSIVE MAINT OF DG SETS OF TECH AREA AT AFS KANPUR AND REPAIR MAINTENANCE OF SECURITY LIGHT, PERIMETER LIGHT AND STREET LIGHTS AND CONNECTED WORKS AT 7 AFH UNDER AOR OF GE (AF) E/M CHAKERI KANPUR
2026_MES_749833_1
8817/E8
Open Tender
Civil Works
Item Rate
270 days
Area under GE(AF)EM Chakeri Kanpur
As per tender document
9 documents required · 9 mandatory
₹500
GE(AF)EM Chakeri
₹1 L
Yes
15 Apr 2026
23 Jan 2026
19 Feb 2026
24 Jan 2026
14 Feb 2026
7 Feb 2026
Complete general servicing of DG set of Capacity :- 5 KVA to 63 KVA of any make which include taking down and replacement / repairs of diesel filter, oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, gaskets, burnt parts & measuring earth resistance values (as required) etc. and tightening of nuts, bolts, washers, greasing, etc for proper running of DG Sets complete all as specified and directed. Note for Ser No 1 to 5:- (i) Cost of fixing charges, oiling, greasing, labour only replacement of engine oil etc. tightening of nuts, bolts and minor work extra are included in the unit rate quoted by the contractor. (ii) Maintenance of Diesel Generating Sets will be carried out and Maintenance records shall be prepared by Contractor and signed by JE E/M & Engineer-in-Charge. All Maintenance register will be provided by the Contractor for record purpose. (iii) The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other taken down unserviceable parts/spares shall be replaced and paid under relevant item of BOQ
All as per serial item No 1.00 above but capacity of DG Set 75 KVA to 100 KVA complete all as specified and directed.
All as per serial item No 1.00 above but capacity of DG Set 125 KVA to 250 KVA complete all as specified and directed.
All as per serial item No 1.00 above but capacity of DG set 320 KVA complete all as specified and directed.
All as per serial item No 1.00 above but capacity of DG set 500 KVA complete all as specified and directed.
Supply only Diesel filter for DG Set of following capacity capacity :- 5 KVA - 62.5 KVA
Supply only Diesel filter for DG Set of following capacity capacity :- 75 KVA to 250 KVA
Supply only Diesel filter for DG Set of following capacity capacity :- 320 KVA to 500 KVA
Supply only Lube filter for DG Set of following capacity:- 5 KVA to 62.5 KVA
Supply only Lube filter for DG Set of following capacity:- 75 KVA to 250 KVA
Supply only Lube filter for DG Set of following capacity:- 320 KVA to 500 KVA
Supply only Air filter for DG Set of following capacity:- 5 KVA to 62.5 KVA
Supply only Air filter for DG Set of following capacity:- 75 KVA to 250 KVA
Supply only Air filter for DG Set of following capacity:- 320 KVA to 500 KVA
Supply of Engine Oil of grade 20W40 in containers and topping up engine oil in DG sets of any capacity complete all as specified and directed. Make: Servo / Castrol / Veedol.
Supply only premixed coolant complete all as specified and directed
Supply only V Belt / Grooved for the DG Sets of capacity 5 KVA to 125 KVA
All as per item no 11 above but 160 KVA to 250 KVA
All as per item no 11 above but 320 KVA to 500 KVA
Supply only Oil pipe complete set for DG Sets of capacity 5 KVA to 500 KVA
Supply only diesel pipe complete set for DG Sets of capacity 5 KVA to 500 KVA
Supply only Rubber hose pipe complete set for DG set of capacity 5 KVA to 125 KVA
All as per item no 16 above but 160 KVA to 250 KVA
All as per item no 16 above but 320 KVA to 500 KVA
S&F Water pump for DG Set complete of capacity 5 KVA to 125 KVA complete all as specified & directed.
All as per item no 19 above but 160 KVA to 250 KVA
All as per item no 19 above but 320 KVA to 500 KVA
S&F Fuel pump for DG Set complete of capacity 5 KVA to 500 KVA complete all as specified & directed.
Taking out FIP (Fuel injection pump) along with its all accessories from DG set of Capacity up to 200 KVA, including transportation to authorised service centre for overhauling / repairs / re-calibration and re-fixing in DG set including replacement of necessary spare parts (as required) such as delivery valves, plungers ‘O’ ring spring, nozzel etc. complete all as specified and as directed.
All as per serial item No 23 above but DG set of capacity 250 KVA to 500KVA complete all as specified and directed.
Removal of radiator from engine of DG set for de-scaling and brazing as required for repairs of water leakage etc. and re-fixing the same properly of capacity upto 200 KVA complete all as specified and directed.
All as per serial item No 25 above but DG set of capacity 250 KVA to 500 KVA .
M&L in replacement of self starter 12 V of any type, capacity, complete all as specified and as directed.
M&L in replacement of self starter 24 V of any type, capacity, complete all as specified and as directed.
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Carbon brush
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Gear pinion assembly
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Carbon bush assembly
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Rocker plate
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Bendix device
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Sloenoid switch
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Armature
M&L in repair/ replacement of following parts of 12V/ 24V self starter :- Starter housing
M&L of removal of self starter of 12V/ 24V capacity, from DG set opening and rewinding of stator complete of existing CU wire guage complete all as specified and diurected
S&F in replacement AVR (Automatic Voltage Regulator) of existing make for DG Set of capacity upto 125 KVA complete all as specified & directed.
All as per item no 31 above but for 160 KVA to 250 KVA.
All as per item no 31 above but for 320 KVA to 500 KVA.
M&L in replacement turbo charger including its accessories of existing make suitable for upto 125 KVA capacity complete all as specified & directed.
All as per serial item No 34 above but capacity of DG set 160 KVA to 250 KVA.
All as per serial item No 34 above but capacity of DG set 320 KVA to 500 KVA.
S&F in replacement digital Microprocessor controller (EPD - Engine protection device) of existing size, make, model & type, having complete features and fixing in Control Panel of DG sets of capacity upto 100 KVA complete all as specified and directed.
All as per serial item No 37 above but capacity of DG set 125 KVA to 200 KVA.
All as per serial item No 37 above but capacity of DG set 250 KVA to 500 KVA.
M&L for programming of microprocessor controller complete as per DG set requirement all as specified and directed by Engr-in-charge'
S&F in replacement of battery terminal bolt type (heavy) suitable for existing AH battery complete all as specified and as directed.
S&F in replacement of battery lead of copper conductor PVC insulated fitted with lead terminal on one side and other side with brass or lead terminal 1.00 m long as per site requirement and connection complete all as specified and as directed.
M&L in replacement of automatic battry charger SMPS type of capacity 12 V
M&L in replacement of automatic battry charger SMPS type of capacity 24 V
S&F in replacement of battery 12 volts and upto 180 AH lead acid type including testing complete having min 36 month warrenttee as provided by manufecturer's complete all as specified & directed. Make : EXIDE / AMARON or other make as approved by GE. NOTE :- Old battery shall be deposite in to AGE E/M-II storeyard
S&F in replacement of battery 12 volts 150 AH lead acid type including testing complete having min 36 month warrenttee as provided by manufecturer's complete all as specified and directed by Engineer in Charge. Make : EXIDE / AMARON or other make as approved by GE. NOTE :- Old battery shall be deposite in to AGE E/M-II storeyard
S&F in replacement of battery 12 volts 90 AH lead acid type including testing complete having min 36 month warrenttee as provided by manufecturer's complete all as specified and directed by Engineer in Charge. Make : EXIDE / AMARON or other make as approved by GE. NOTE :- Old battery shall be deposite in to AGE E/M-II storeyard
S&F in replacement old /unserviceable Pad lock assembly complete, by disconnecting and taking out including replacement of nut, bolts etc. suitable for silent type DG set door for capacity upto 250 KVA complete all as specified and directed.
All as per serial item No 48 above but capacity of DG set 320 KVA to 500 KVA.
Material and labour for painting of DG Set, canopy and panel with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including writing i.e MES No, Capacity etc. as per existing pattern etc complete all as specified and directed. Capacity of DG Set 5 KVA to 63 KVA.
All as per serial item No 50 above but for capacity of DG Set 75 KVA to 200 KVA.
All as per serial item No 50 above but for capacity of DG set 250 KVA to 500 KVA.
M&L in replacement of door hinges suitable for silent type DG set, complete all as specified and directed
M&L in Repair/ repalcement of following parts of AMF panel suitable for DG set of capacity upto 500 KVA capacity including fixing arrangement complete all as specified and as directed for :- (a) Supply & fixing of HRC fuse complete with element 100 to 250 Amps
(b) Supply & fixing of Voltmeter 0-500 Volt square or otherwise flush pattern of existing make and size complete all as specified and directed.
(c) Supply & fixing of Ammeter any range flush pattern size as existing make and size complete all as specified and directed.
(d) Supply & fixing of Indicator Lamp (RYB) complete all as specified and directed.
(e) Supply & fixing of Ignition switch of 12/24 Volts complete all as specified & directed.
(f) Supply & fixing of CT 50/5 complete all as specified & directed.
(g) Supply & fixing of CT 500/5 complete all as specified & directed.
(h) Supply & fixing of Solenoid switch 12/24 Volts with relay of existing make and capacity complete all as specified & directed.
(j) Supply & fixing of voltage monotoring relay (VMR) complete all as specified & directed.
(k) Supply & fixing of display card
(l) Supply & fixing of power/ control card 12V / 24V , 70 Amp
(m) Supply & fixing of electronic speed controller (governor card) of cacpcity suitable for DG set from 10 KVA to 125 KVA
(n) Supply & fixing of electronic speed controller of cacpcity (Governor card) suitable for DG set from 160 KVA to 250 KVA
(n) Supply & fixing of electronic speed controller of cacpcity (Governor card) suitable for DG set from 320 KVA
(n) Supply & fixing of electronic speed controller of cacpcity (Governor card)/ double acutator suitable for DG set from 500 KVA
Supply and fixing in replacement of single phase preventer/phase sequencer relay suitable for upto 500 KVA DG Set AMF Panel all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MNX 650, 3 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MNX 110, 3 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MCX 45, 4 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MCX 41, 4 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MCX 33, 4 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power Contactor MCX 22, 4 pole , 415 volts, 50 Hz AC supply all as per sample and specified and directed by Engineer-in-Charge.
Receiving Electrical & Mechanical complaints related to DG sets installed at AFS, Chakeri & allied units from Complaint section / JE E&M / Engr-In Charge & attending the same within 2 hrs. This item is inclusive of all preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues, removing air lock (if any), reconnecting the DG set back for proper functioning.
Supply & fixing in replacement of alternator 12 volts capacity
Supply & fixing in replacement of alternator 24 volts capacity
M&L for repair/ replacement of DC canopy light 12/ 24V, complete with all wiring arrangemet of suitable size along with toggle switch complete all as specified and directed
M&L in replacement of emergency switch of mushroom type complete set
M&L in replacement of push button assembly complete with element
Collection of DHPP from Airforce MT Sec to MES MT Sec and Transportation of DHPP to any DG set in Air force station, Chakeri, Kanpur in containers of above 100 litres and pouring in tanks of DG sets complete all as specified and as directed. Note:-Transportation of One container duly filled with DHPP shall be considered as one Job for payment purpose.
S&F in replacement of on-load type change over switch on load front handle 4 pole 415 volt 50 Hz 63 Amps with enclosure including mounting arrangement of metallic frame work of appropriate section and size on walls or panels complete all as specified and as directed. Make:- Havells / L&T / Legrand. Note :- Making connections to the electric system including cutting of cables of any size and type, making and termination by using suitable lugs is included in the rate quoted under this item.
All as per serial item No 69 above but 4 pole 415 volt 50 Hz 125 Amps.
All as per serial item No 69 above but 4 pole 415 volt 50 Hz 200 Amps .
All as per serial item No 69 above but 4 pole 415 volt 50 Hz 250 Amps .
All as per serial item No 69 above but 4 pole 415 volt 50 Hz 400 Amps .
Supply, laying in ducts/trenches or fixing on wall/pole etc test and commissioning (in replacement) of LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable heavy duty with multi stranded aluminium conductor 1100 V grade cross sectional are 50 Sqmm 3.5 Core suitable for earthed system including taking out old unserviceable cable complete all as specified and directed.
All as per serial item No 74 above but size 70 Sqmm 3.5 Core complete all as specified and directed.
All as per serial item No 74 above but size 95 Sqmm 3.5 Core complete all as specified and directed.
M&L for complete overhauling Diesel Engine by opening top head, cleaning of engine of Generator and replace worned out parts of engine, Checking and setting right the alignment of Engine & Alternator, servicing of engine for smooth running, observing & setting correctly the unusual sound & color of smoke from exhaust (if any), repairing the leakage of fuel, lubricating oil & coolant, repairing of Accessories drive, Turbocharger and crankshaft endplay, rewinding of burnt armature of rotor / stator, greasing, cleaning, removal of carbon deposits and other unwanted reminants, re-assembling the complete engine, fixing it in position and testing on load complete all as specified & directed. Capacity :- 10KVA to 82.5 KVA DG Set. Note:- . The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other unserviceable parts/spares shall be paid under relevant BOQ Item
Supply only Piston Assembly including pistons ring set of existing make complete all as specified and directed. Note: Old unserviceable Piston Assembly will be deposited by the contractor in E/M store yard.
Supply only Cylinder liner ‘O’ ring kit of existing make of DG set complete all as specified and directed.
Supply only Main bearing set of existing make of DG set complete all as specified and directed.
Supply only Oil pump set of existing make of DG set complete all as specified and directed.
Supply only Valve (inlet and outlet valve) of exisiting make of DG set complete all as specified and directed.
Supply only Head Gaskets set of existing make complete all as specified and directed.
Supply only Connecting rod bearing kit of existing make complete all as specified and directed.
M&L for overhauling of complete diesel engine by opening top head , cleaning of engine of Generator and replace worned out parts of engine, Checking and setting right the alignment of Engine & Alternator, servicing of engine for smooth running,observing & setting correctly the unusual sound & color of smoke from exhaust (if any), repairing the leakage of fuel, lubricating oil & coolant, repairing of Accessories drive, Turbocharger and crankshaft endplay, rewinding of burnt armature of rotor / stator, greasing, cleaning, removal of carbon deposits and other unwanted reminants, re-assembling the complete engine, fixing it in position and testing on load complete all as specified & directed. Capacity :- 100 KVA to 180 KVA DG Set. Note:- The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other unserviceable parts/spares shall be paid under relevant BOQ Items
Supply only Piston Assembly including pistons ring set of existing make complete all as specified and directed. Note: Old unseviceable Piston Assembly will be deposited by the contractor in E/M store yard.
Supply only Cylinder liner ‘O’ ring kit of existing make of DG set complete all as specified and directed.
Supply only Main bearing set of existing make of DG set complete all as specified and directed.
Supply only Oil pump set of existing make of DG set complete all as specified and directed.
Supply only Valve (inlet and outlet valve) of exisiting make of DG set complete all as specified and directed.
Supply only Head Gaskets set of existing make complete all as specified and directed.
Supply only Connecting rod bearing kit of existing make complete all as specified and directed.
M&L for overhauling of complete diesel engine by opening top head , cleaning of engine of Generator and replace worned out parts of engine, Checking and setting right the alignment of Engine & Alternator, servicing of engine for smooth running,observing & setting correctly the unusual sound & color of smoke from exhaust (if any), repairing the leakage of fuel, lubricating oil & coolant, repairing of Accessories drive, Turbocharger and crankshaft endplay, rewinding of burnt armature of rotor / stator, greasing, cleaning, removal of carbon deposits and other unwanted reminants, re-assembling the complete engine, fixing it in position and testing on load complete all as specified & directed. Capacity :- 200 KVA - 320 KVA DG Set. Note:- The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other unserviceable parts/spares shall be paid under relevant BOQ Items
Supply only Piston Assembly including. pistons ring set of existing make complete all as specified and directed. Note: Old unseviceable Piston Assembly will be deposited by the contractor in E/M store yard.
Supply only Cylinder liner ‘O’ ring kit of existing make of DG set complete all as specified and directed.
Supply only Main bearing set of existing make of DG set complete all as specified and directed.
Supply only Oil pump set of existing make of DG set complete all as specified and directed.
Supply only Valve (inlet and outlet valve) of exisiting make of DG set complete all as specified and directed.
Supply only Head Gasket set of existing make complete all as specified and directed.
Supply only Connecting rod bearing kit of existing make complete all as specified and directed.
M&L for overhauling of complete diesel engine by opening top head , cleaning of engine of Generator and replace worned out parts of engine, Checking and setting right the alignment of Engine & Alternator, servicing of engine for smooth running,observing & setting correctly the unusual sound & color of smoke from exhaust (if any), repairing the leakage of fuel, lubricating oil & coolant, repairing of Accessories drive, Turbocharger and crankshaft endplay, rewinding of burnt armature of rotor / stator, greasing, cleaning, removal of carbon deposits and other unwanted reminants, re-assembling the complete engine, fixing it in position and testing on load complete all as specified & directed. Capacity :- 500 KVA DG Set. Note:- The taken down spares shall be cleaned and refitted on DG sets, if found serviceable. All other unserviceable parts/spares shall be paid under relevant BOQ Items
Supply only Piston Assembly incl. pistons ring set of existing make complete all as specified and directed. Note: Old unseviceable Piston Assembly will be deposited by the contractor in E/M store yard.
Supply only Cylinder liner ‘O’ ring kit of existing make of DG set complete all as specified and directed.
Supply only Main bearing set of existing make of DG set complete all as specified and directed.
Supply only Oil pump set of existing make of DG set complete all as specified and directed.
Supply only Valve (inlet and outlet valve) of exisiting make of DG set complete all as specified and directed.
Supply only Head Gasket set of existing make complete all as specified and directed.
Supply only Connecting rod bearing kit of existing make complete all as specified and directed.
Disconnecting the connection from prime mover including taking out of Armeture set of capacity upto 125 KVA from the existing position and strip opening, cutting the burnt out winding in feild coil, cleaning the stator and re-winding the same with super enameled copper winding wire of same gauge using top class of insulating material and over hauling of armeture including lath/ machine work for making housing of bearing , metaling ,welding, turning surfacing ,polishing of rotor shaft, and rethreading and replacement of, bearing of required size (Make-NBC/SKF), bushes, rubber insertion sheet , nuts, bolts and washers including necessary other items for its smooth functioning and testing complete reassembling the same and re-fixing back in its original position complete all as specified and as directed. Note : MES/SM Number of DG set shall be recorded in MB.
Supply and Fix in replacement MCCB TPN 400 Amps , 415 Volts, 36 KA ,4 Pole, Ics=100% Icu , with microprocessor release (4 pole) overload adjustable short circuit adjustable type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB TPN 250 Amps , 415 Volts, 36 KA ,4 Pole, Ics=100% Icu , with microprocessor release (4 pole) overload adjustable short circuit adjustable type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB TPN 160 Amps , 415 Volts, 50 KA ,4 Pole, Ics=100% Icu , with microprocessor release (4 pole) overload adjustable short circuit adjustable type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and filling find sand ( or stone dust ) to the full width of trenches for protection of cables including spreading and punning down complete of all as specified. Note : Punned thickness of sand shall be measured for payment purpose
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Taking up/ down of 40 mm bore steel tubing and connections from excavated trenches and building up to tripple storey with due care including removal from site complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors for protection of LT cable, complete all as specified and directed.
S& F in replacement of fuel level indicator pipe upto 125 KVA DG set including all accessories required for fitting of fuel pipe all as sppecified & directed by Engr-in-charge.Note : Necessary addition /altration required to adjust fuel pipe in the panel shall be done by the contractor and no extra payment will be made to the contractor.
S& F in replacement of fuel level indicator pipe of capacity 160 to 250 KVA DG set including all accessories required for fitting of fuel pipe all as sppecified & directed by Engr-in-charge.Note : Necessary addition /altration required to adjust fuel pipe in the panel shall be done by the contractor and no extra payment will be made to the contractor.
S& F in replacement of fuel level indicator pipe for 320 KVA to 500 KVA DG set including all accessories required for fitting of fuel pipe all as sppecified & directed by Engr-in-charge.Note : Necessary addition /altration required to adjust fuel pipe in the panel shall be done by the contractor and no extra payment will be made to the contractor.
Supply & filling of Diesel exhaust fluid (DEF), of appoved make as required/ recommended by OEM of DG set all as specified and directed by Engr-in-charge
Supply & fixing in replacement LT PVC tape roll 3/4 inch size ISI marked of length 25/26 mtr.
S&F in replacement of Aluminium Lugs/connectors/ferul of size 70 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 95 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 120 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 150 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 185 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 240 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 300 sqmm
S&F in replacement of Aluminium Lugs/connectors/ferul of size 400 sqmm
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out insoft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for double walled corrugated DWC HDPE pipe of outer dia 50mm inner dia including 90 degree bends with coupler and rubber ring laid in trenches of size 50mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50sqmm cable complete all as specified and directed.
S&F in replacement of GI tubing light grade 40mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 16sq mm 4 core. laid in trench/ duct / pole/wall etc passinf thoriugh pipe including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete including taking down complete all as specified directed. Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Description all as per item No. 135 above but cross sectional area 25 Sqmm 4 core complete all as specified and directed.
Description all as per item No. 135 above but cross sectional area 10 Sqmm 4 core complete all as specified and directed.
Description all as per item No. 135 above but cross sectional area 6 Sqmm 2 core complete all as specified and directed.
M&L for inreplacement of Batten holder for retrofit universal type as directed by Engineer -in - charge
Supply and fix in repair LED bulb 9 watt, for Garden light/ Post Top, as directed by EIC.
M&L for Plain cement concrete (1: 2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including dismantling of old crack/damaged coping, necessary form work for rough finished surfaces complete all specified and directed.
S&F in replacement of pole box of size 155 x 210 x 92 for street light dust and vermin proof make Sintex model GSJB 3020 complete with aluminum bus bar 04 nos. of capacity 100 amps on epoxy insulators including one MCB SP C series 06 amps 10 KA capacity for security light connection including suitable clamps & suitable size brass chrome plated glands-02 nos at bottom for cable entry and exit complete all as specified and directed. Note:- All cable connections shall be made with using suitable cable lugs.
Supply and fixing in replacement of Energy saving & Enviroment friendly LED street light fitting having capacity 45 watt made out of pressure die cast anodized alluminium housing with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP protection IP 65 or better complete etc all as specified and directed. Note: 1. Manufecturer's guarentee certifcate of LED along with its PVrs shall be submitted while claiming payment. 2. Metal level indicating name of agency & contract number shall be affixed in the LED light. This shall be deemed to be included in quoted unit rates
Supply and fixing in replacement of Energy saving & Enviroment friendly LED street light fitting LED street light fitting having capacity 90 watt made out of pressure die cast anodized alluminium housing with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP protection IP 65 or better complete etc all as specified and directed. Note: 1. Manufecturer's guarentee certifcate of LED along with its PVrs shall be submitted while claiming payment. 2. Metal level indicating name of agency & contract number shall be affixed in the LED light. This shall be deemed to be included in quoted unit rates
Supply and fixing in replacement of LED Flood lights 150 watt with high luminus efficacy, protected to IP65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed. Note: 1. Manufecturer's guarentee certifcate of LED along with its PVrs shall be submitted while claiming payment. 2. Metal level indicating name of agency & contract number shall be affixed in the LED light. This shall be deemed to be included in quoted unit rates
All as per item No 145 but LED flood lights 200 Watt.
S & F in replacement decorative post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Note: 1. Manufecturer's guarentee certifcate of LED along with its PVrs shall be submitted while claiming payment. 2. Metal level indicating name of agency & contract number shall be affixed in the LED light. This shall be deemed to be included in quoted unit rates
Material and Labour in replacement of Garden light Fitting Integral Bollards decorative luminaire energy saving environmental friendly, long life aesthetically designed aluminium landscape luminaire diffused lighting with high power LED as light source 10W 4000K(500mm) and accessories complete incuding cable connector, MS shunken box & bakelite sheet of size 7"x4", PCC work & all type of fixing arrengement all as specified and directed by Engineer-in-Charge. Note: 1. Manufecturer's guarentee certifcate of LED along with its PVrs shall be submitted while claiming payment. 2. Metal level indicating name of agency & contract number shall be affixed in the LED light. This shall be deemed to be included in quoted unit rates
Supply and fixing in replacement of insulated unsheathed PVC FRLS three core stranded copper conductor 1.5 sqmm x 2 + 1.5 sqmm for earth contuinity conductor drwan through steel conduit pipe of medium grade fixed to pole with fixing arrangement woking voltage 1100 volts grade 50HZ cconforming to IS-694 from junction box to street light fitting or for OH connections complete all as specified and directed. (Note : 7 Rm per pole )
M&L for dismantling of non-functional street light/flood light from any type of pole at hight up to 12 mtr LTpole by suitable ladder for repair of the same for replacement unserviceable parts like LED driver, connector block and decarbonizing contact points and refixing the same to pole after repair of any type security/street/flood light all as specified and directed by EIC. Note :- (i) Required LED driver shall be measured and paid separately as supply only. (ii) Required screws, insulating tapes, gaskets, and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iii) Taking down unserviceable street/security light fittings of any type,wattage and make from LT poles and transporting from site to MES store yard for repairing in deemed to be includ in this item rate. The defective street light fittings will be repaired only at MES yard/place where over directed by Engr-in-Charge.
Supply and fixing LED driver suitable for street/ security /flood light fitting 60/70/90 watt 230 V any type/make all as specified and directed.
Supply and fixing LED driver suitable for street/security /flood light fitting 120/150/200 watt 230 Vany type/make all as specified and directed.
Scrapping, cleaning, and preparation of steel tubuler pole (up to 11 mtr long) incl brakets, nut bolts fitting complete and M & L for painting by one coat of aluminium paint after preparation of the steel surfaces including two coat blue & white paint in strap alternatively all round the poles. Hight of the strap shall be 30cm and Nos of strap shall be 05 Nos including pole number complete all as specified and directed by EIC.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
M & L for boaring manually in any type of soil under road 60cm below the top surface of road complete for passing through 40mm to 50mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables etc of any type will made good by the tenderer without any extra payment.
M&L for taking out loop of LT XLPE cable of size 10sqmm x 2/4 core to 35sqmm 3.5/4 core, cutting the damage piece of cable, prepare the ends of cable, jointing the piece of cable of same size with the help of ferrul, applying sleeve on all 2/3.5/4 core cable and lugs the end of extended cable, making connection to the pole box/CT panel. Removing veeds upto 1 mtr redius of LT pole/ panel by surface dressing and removal of veeds/grass to location as directed by EIC. Note: (i) Rates of all the items mentioned above should be included the rates quoted by contractor. (ii) Rates for XLPE cable should be mesured in respective item of contract.
Lowering of high mast light assembly from upto 16/12 Mtr high mast,any type,make and wattage, dismantling, checking parts and components for replacement, if required, and making the light fittings operational to give rated illumination incl cleaning of glass cover and refixing the same after repair/replacement of defective components complete with necessary electrical connection with by providing 3 core 2.5 Sqmm PVC sheathed multi stranded copper conductor cable of required length complete all as specified and directed. Note :- The cost of greasing of pully, roller, bearing and gear including refixing of rope clamps, adjustment of lock, leaver etc shall be deemed to include the quoted rate.
stage.html
html • 0.05 MB
technical_839767.pdf
techsummary_839767.pdf
finance_839767.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.01 MB
Workdetails.pdf
Additional Documents • 0.09 MB
8817E8_CreditSchdule_1.pdf
Additional Documents • 0.20 MB
BOQ_839767.xls
BOQ • 0.51 MB
8817E8_Tender_1.pdf
Tender Documents • 0.77 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .