Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC Stands L1 and satisfactory | |
| 2 | L2₹2.4 L+₹2,358.28 (1.00%)Rejected-Finance 223 N DHARMAPALLY TENTULTALA ASANSOL BURDWAN WEST BENGAL 713304 | ASANSOL | BURDWAN | WEST BENGAL | 713304 | L2 | Rejected-Finance Stands L2 | |
| 3 | L3₹2.4 L+₹3,538.12 (1.50%)Rejected-Finance KALYANESWARI PASCHIM BARDHAMAN WEST BENGAL | KALYANESWARI | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance Stands L3 | |
| 4 | L4₹2.4 L+₹4,716.69 (2.00%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L4 | Rejected-Finance Stands L4 |
Tender Value
Refer Docs
EMD Value
₹5,500
Closing Date
16 Sept 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Asansol Mech Divn PHE Dte
Janasasthya Karigori Bhaban, Sen-Releigh Road, Opp ESI Hospital, Asansol - 05
Replacement of indoor lighting accessories and allied works at Baidyanathpur Pump House under Baidyanathpur Water Supply Scheme.
2022_PHED_400166_1
WBPHE /EE/AMD/NIT 19e / 2022-2023
Open Tender
Electrical Work/ Equipment
Item Wise
10 days
Baidyanathpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,500
13 Oct 2022
31 Aug 2022
19 Sept 2022
31 Aug 2022
16 Sept 2022
31 Aug 2022
Amount
Supply & delivery of following accessoies :-
1H.P MK1 DOL Starters Suitable for Pump/Motor 3Ø, Relay Range (A)-(1.5-2.5) (Make-L&T, SS96210POPO,
63A MCCB, 3pole, 25kA (3VA MCCB, Thermal Magnetic Trip Unit, Fixed Thermal Fixed Magnetic), Ics = 100% Icu, 415VAC, 50Hz (Siemens, 3VA1063-3ED32-0AA0)
32A(AC3 Rating) 3 Pole Power Contactors block (Make-L&T, MNX-32, CS94111)
25A(AC3 Rating) 3 Pole Power Contactors block (Make-L&T, MNX-25, CS94110)
Front Mounting Add-on aux. Contact Block (2 NO + 2 NC), (Make-L&T, for MNX-25, CS94114)
Front Mounting Add-on aux. Contact Block (1 NO + 1 NC), (Make-L&T, for MNX-32, CS94118)
Electronic Overcurrent Relay (BOCR 3EZ, Current Range - 0.5-60A, MP363EZ800, Make-BCH)
MN 2 (Directly Operated) Thermal Overload Relays [Relay Range-(9 - 15)A, SS94142OOBO, Make-L&T]
Star Delta Timer (Micon 175, Range-3 sec - 120 sec, 240VAC, 1 NO (Star)+1 NO (Delta), 12SDT0, Make-GIC)
ON Delay timer (Micon 175, Range-0.3 sec - 30 hrs, 240VAC, 1 C/O, 12ODT4, Make-GIC)
Gen Next LED Indicator (RED,GREEN & AMBER) 240 VAC (GIC)
Start push button (22.5mm) with 1NO contact (Make-Siemens, Red- 3SU1000-0AB20-0AA0 & Green-3SU1000-0AB40-0AA0)
Contact Blocks for Push button [1 NO(3SB5400-0B)& 1NC(3SB5400-0C), Make-Siemens,
Analog Ammeter, (0-100A) CL-1.5, 96mm x 96mm (Make-AE)
CT, 100/5A, 5VA, CL-1 (AE)
6Amp SP MCB (Siemens, C-Curve, 5SL41067RC)
6Amp TP MCB (Siemens, C-Curve, 5SL43067RC)
Capacitor Duty Contactors, 5kVAr Rating @ 440V, 3Ph, 50Hz (Type-MO C5, 1NO, CS96127, Make-L&T)
4KVAr 3Ph, PhiCap Heavy Duty PhiCap HD ROU- 440 V(AC) 50Hz (Epcos, B32447A4022B 40)
Fitting & fixing of above supplied accessories (Item no-2) and other related accessories on their original position of MCC panel and connecting the control wire to complete the control circuit with the whole system after supplying the required wire (6sqmm, 4sqmm, 2.5sqmm stranded copper wire as and where required) as per direction. This including the cost of testing the whole installation upto entire satisfaction of EIC.
Dismantling and lowering of the outdoor lighting luminaries from the ceilling top of pump house room etc as per direction.
Supply & delivery of 100W LED Highbay solution with PDC housing, toughened & shattered proof glass available in wide beam optics, IP66 protected. (Philips, BY325P LED100S CW PSU GR FG WB XTFCL V1)
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. a) (2 x 2.5 sqmm + 1 x1.5 sqmm) (For Chlorine Starter panel & both highbay lights)
Earthing with G. I. Earth spike. (1822 x 20mm ) and grouted the same under the ground level as per direction. (For chlorine Starter panel)
Connecting the equipments (light fixture & Pole box) to earth busbar including S & F of 8 SWG GI (Hot Dip) wire after making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as per direction.
Fixing only high bay light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
Installation and commissioning of the department supplied Chlorinator with all accessories, PVC tank and drawing of power line as per IE rules by supplying of necessary wire and continuous earthing. This include the cost of all necessary CC foundation [at least 200mm height] with concrete mixture [sand, cement, stone, chips] and neat cement finish by supplying of all required materials and testing the entire set as per direction of EIC.
Add. GST@18%
Add. Cess@1%
BENGAL CONSTRUCTION
SUNRISE ENGINEERING CORPORATION
EASTERN INDIA SALES AND SERVICE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .