Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹13.4 L+₹53,330 (4.14%)Rejected-Finance GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹16.0 L+₹3.1 L (24.1%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹21.2 L+₹8.3 L (64.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest |
Tender Value
₹14.6 L
EMD Value
₹29,300
Closing Date
29 Nov 2022, 4:00 pmClosed
GE (P) central
GE (P) Central Brichgunj Military Station Port Blair-744103
COMPREHENSIVE MAINT OF ELECTRIC AND WATER SUPPLY, WDI, SIGN BOARD ETC AND AIR FIELD AT INS UTKROSH UNDER GE (P) CENTRAL, PORT BLAIR
2022_MES_561540_1
8088/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
INS Utkrosh
Class E, Category b(i)
8 documents required · 8 mandatory
₹500
GE (P) Central, Port Blair
₹29,300
Yes
14 Jan 2023
4 Nov 2022
5 Dec 2022
4 Nov 2022
29 Nov 2022
16 Nov 2022
4 Nov 2022 - 14 Nov 2022
Amount
Removal of old WDI pole and supply & fix in repairs of frangible Wind Direction Indicator in compliance with Annexure 14, Vol. I par. 5.1.1 & full compliance with FAA, AC No. 150/5345-45. Frangible fiber glass Mast of red/ white of size 400x400x4500mm approx. Resistance to wind to minimum 140km/ hrs. easy lowering arrangement for maintenance without re-alignment required, Windsock in ICAO Red/ White or black white as directed of length 3.6 mtr x dia 0.9m of nylon fabric, water repellant & resistant to rotting and mildew, External & Internal LED lighting, mast assembly fitted with LED obstruction light complete with base of PCC as per OEM ditections, all as per specified and as directed by Engineer-in-Charge at site.
Supply and fix in repair/ replacement of LED light fitting 25 Watt outdoor type light fitting alongwith required LED lamp, pressure die cast aluminium housing, heat resistant glass, IP 65 protection and fixed on wind direction indicator pole using necessary GI clamps, bolts, nuts and washer including provision of copper flexible twin twisted PVC insulated cable complete all as specified and directed.
Repair of signage board, replacement of fadded signage sticker (as per originally on the signage board), replacement/ repair of damaged fixing pole, proper sealing with application of silicon gel, connection with flexible PVC insulated cable 1.5 sqmm etc complete as per direction for proper functioning of board.
Supply and laying in repair/ replacement XLPE insulated heavy duty screened PVC bedded, galvanized steel strip or wire armored, electric power cables 1100 Volts grade with stranded aluminum conductor confirming to IS 7098 all as specified of 35 sqmm 3.5 core size.
Supply and laying in repair/ replacement XLPE insulated heavy duty screened PVC bedded, galvanized steel strip or wire armored, electric power cables 1100 Volts grade with stranded aluminum conductor confirming to IS 7098 all as specified of 10 sqmm 2 core size.
Taking down old unserviceable pipe including Supply & laying of 63/50 mm dia SN-4 class-DWC (HDPE) pipe at suitable depth and making digged surface well as per previous, with full coupler. Coupler should be fixed properly ,all as specified & directed by Engineer-in-Charge at site. Make- Syntex, Supreme, Gemini
Taking down old unserviceable tube light fitting & Supply and fix new LED batten of 18 watt of Crompton catpart no. LPLLA-18-CDL or equivalent in Philips/Havells/Bajaj as per directed.
S&F in repairs GI pipe light grade of 50 mm dia with necessary fittings, cutting if any required all as specified & directed by Engineer-in-charge
M & L PCC type B1 using 20mm grade stone agregate 1:2:4 grade all as specified and directed.
Excavation in trenches n exc 1.5m wide and n.exc 1.5 m in depth for laying of cable, foundation etc. n exc 10 sqm on plan and nexc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, refilling in layers including spreading levelling, watering and well ramming in layers not exc 25 Cm all as specified and directed.
Removal of surplus excavated soil not exc 50 mtrs and deposting where directed at level not exc 1.5 mtr above the starting point all as specified and directed.
S&F LT jointing kit 1.1 KV epoxy PVC/ XLPE straight through joint suitable for 25/ 35 Sqmm 3.5 core complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .