Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.1 L+₹23,376.92 (2.36%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹11.3 L+₹1.4 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹11.5 L+₹1.6 L (15.7%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹12.0 L+₹2.0 L (20.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
17 Nov 2021, 6:00 pmClosed
GE Dronachal
Garrison Engineer Dronachal, Dronachal Top, Neori Hills, Bhopal-462038
PROVN OF SECURITY LIGHT ALONG THE PERIMETER FENCING OF UNIT ADJACENT TO CIVIL AREA FROM DRONACHAL REAR GATE TO NEORI GATE OF 7021 EME BN AT DRONACHAL TOP, BHOPAL
2021_MES_482745_1
8648/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
Class-E, Category b (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
GE Dronachal
₹29,000
Yes
19 Jan 2022
20 Oct 2021
19 Nov 2021
20 Oct 2021
17 Nov 2021
3 Nov 2021
21 Oct 2021 - 2 Nov 2021
Amount
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure dia cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing GI bracket 1.2 mtr long 40 MM dia complete alongwith MS clamp bolts and nuts of suitable size for fixing of bracket complete all as specified and directed.
Supply and laying XLPE 1100 volts grade heavy duty with PVC insulated, armoured cable, 4 core 10 sqmm in service supply connection passing through trenches, walls, road crossings and poles complete all as specified and directed.
Supply and laying XLPE 1100 volts grade heavy duty with PVC insulated, armoured cable, 3.5 core 35 sqmm in service supply connection passing through trenches, walls, road crossings and poles complete all as specified and directed.
Excavation in trenches in soft/loose of soil not exceeding 1.5m deep and not exceeding 1.5 m wide and getting out complete all as specified and directed.
Excavation in trenches and exceeding 1.5m in depth but not exceeding 3.00 m deep for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , all as specified and directed at site.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work , all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , with two coat of lime wash on coping and all as specified and directed.
Supply and spread dry river sand for UG cable cushioning including punning on top and bottom of the cable complete all as specified and directed.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
S&F in replacement of GI Pipe medium grade on wall/floor for cable protection with fixing arrangement size 40mm dia.
M&L cutting PCC/floor/road and taking out cable and making good, with material as per existing after laying of pipe for cable protection including Cement concrete work in pavement/ hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or lessall as specified and directed size of trench not more than 0.30 x 0.30 cm.
Supply and fix in replacement of service cable flat/circular copper of size 1.5 Sqmm 3 core complete all as specified and directed.
Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate and finial including foundation and coping, painting with aluminium paint complete all as specified and directed.
Earthing complete with galvanized earth plate electrode of size 600x600x6.0 mm ,buried directly in ground (earth pit not less than2.25 mtrs below normal ground level)with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts ,nuts ,check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate no 5of SSR part 1991, 40 mm dia watering pipe light grade 1.70 mtr long with plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including testing after completion. Note :-(i)maximum length of GI wire ,protection pipe with each earth shall not exceed 7.5 mtrs . (ii)the 40 mm dia watering pipe shall be 20 cm above the ground level and be provided with 40 mm dia GI plug at top and no concrete watering pit/cover shall be provided.
Supply installation, testing and commissioning LT panel outdoor type cubicle panel board suitable for 3 phase 4 wire 415 volt, 50 Hz, factory made CPRI approved, powder coated made out of 3.15mm thick CRCA sheet and MS angle iron section 40x40x6mm frame with front and back openable double door system with locking arrangement, louver and air vent gasket for natural flow of air with canopy, inner compartment made out of 2mm thick CRCA sheet duly compatmentalized for each MCCB of incoming and outgoing with lockable arrangement with aluminium bus bar three phase and neutral of capacity of 200amp, marked red, yellow, blue & black insulators, made of high strength insulated material suitable for 1100 voltage all control PVC wires shall be with 2.5sqmm multistranded copper conductor and shall be properly bunched, tied, feruled for proper indication, fixed on PCC foundation complete with following accessroies: - (a) MCCB 63 Amp with thermal magnetic release adjustable type, breaking capacity 16kA , 4 pole- 01 No. (b) MCCB 40 Amp with adjustable thermal range, 16kA, 415 volt, 4 pole- 03 No. (c) Contactor ML3 - 01 No. (d) Timer switch 16Amp -01 No. (d) Digital type ammeter 0-400amp square type- 01 No. (e) Digital type voltmeter 0-500 Volts square type- 01 No (f) Indicator lamp LED type, set of three maked RYB- 01 Set
Supply & fix street light junction box of size 300 x200 x105 mm inner dimension made out of FRP sheet with weather proof hinged doors, locking arrangements horizontal / vertical operated with 6 amps MCB SP, along with provision of 04 Nos aluminium bus bar of capacity 40 Amps and including fixing arrangement with 25mm x3mm MS flat iron clamps and nut bolts etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
HRK ENGINEERING CORPORATION
M/s H V Infra Projects
POONAM ELECTRIC INDUSTRY
Mukesh Enterprises
M/S RAKESH TRADERS
MODI CORPORATION
UMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .