Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-Finance 3 218 VASTU KHAND 3 218 VASTU KHAND GOMTI NAGAR LUCKNOW GOMTI NGAR LUCKNOW UTTAR PRADESH 226010 INDIA | LUCKNOW | UTTAR PRADESH | 226010 | L1 | Accepted-Finance SINGLE TECHNICALLY QUALIFIED VENDOR | |
| 2 | Rejected-Technical | - | Rejected-Technical Technically Not Qualified |
Tender Value
Refer Docs
EMD Value
₹21,000
Closing Date
7 Sept 2024, 9:30 amClosed
REGISTRAR
JADAVPUR UNIVERSITY MAIN CAMPUS
Supply and Installation 01 No. Electrochemical Workstation at Chemistry Department Department of Jadavpur University Main Campus Kolkata
2024_JU_737297_1
JU/e-tender/COMP/07/2nd Call/2024-25
Open Tender
Equipments
Item Rate
14 days
JADAVPUR UNIVERSITY MAIN CAMPUS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹21,000
Yes
3 Oct 2024
22 Aug 2024
9 Sept 2024
22 Aug 2024
7 Sept 2024
22 Aug 2024
Amount
Electrochemical Workstation
No. of channel: 1 Interface: USB Measured current/Potential resolution: 0.0033% full scale/bit Applied Potential Resolution: 150 MicroV or Better IMP Amplitude Range: 0.00001 V- 0.7 V RMS Electrode Configuration, Terminals: 2,3,4 and 5 Potentiostat Rise time: 400ns or better Reference Electrode Input Impedance: > 10TOhm Current Range: 100nA - 1A or Better Compliance Voltage: +/- 12 V or Better Scan Rate: 10 microV/s to 10000 V/s or Better-0.1 mV/s Potentiostat Bandwidth: 10Mhz or Better Reference Electrode Input Bias Current: 1 pA or Better Applied Current Resolution: 0.03% of Current Range or Better Maximum Current: +/-1 A or Better Bandwidth of Electrometer: 10MHz or Better IMP Frequency Range10µHZ to 2MHz Maximum Potential: +/- 10 V or Better Additional Information Feature: Licensed and full version of software provision for measurement of I-V measurements, Imax, Pmax fill factor etc. upgradation of software should be made as and whenever required, computer with latest version of windows OS compatible with instrument software. Additional Requirements 1. Instrument should come with multichannel (8channel) dummy cell for external cell calibration & also with EMI shielding & GND option. 2. Instrument should be having interface for spectro-electrochemistry analysis. 3. Instrument must be having floating/GND option. 4. Instrument software must be able to support multiple channels with Multichannel add on facility and also should be having custom experiment design option with multiple voltage/current waveforms. Electrochemical Cell System & Accessories: Ag/Agcl reference electrode(B10) -1qty, Platinum mesh electrode (1x1cm) - 1qty, Working electrode holder (clip type)-1qty, Gastight cell with stand (20ml)-1qty Warranty Summary: 2 Years Upgradable option: There should be a provision that in future the system will use in Spectro-electrochemistry Setup. System should be upgradable to Bipotentiostat in future Techniques: Cyclic Voltammetry, Rapid alternating Polarity, Linear Sweep Voltammetry, Tafel Plot (TAFEL) potentiodynamic deactivation, pitting corrosion, corrosion rate, linear Polarization, Corrosion current etc, Chrono Amperometry, Chrono Coulometry, Differential Pulse Voltammetry, Amperometric i-t Curve, Bulk Electrolysis with Coulometry, AC Impedance, Impedance - Time, Impedance - Potential, Chrono Potentiometry, Chronopotentiometry with Current Ramp, Multi-Current Steps, Potentiometric Stripping Analysis, Open Circuit Potential - Time, Galvanostat, IR Compensation, Bode and Nyquist & Mott-Schottky plot, Chronoamperometry, Pulsed Voltammetry (SCP, NPV, DPV & SWV), OCP Measurement, Tafel Analysis (Corrosion Measurement),Linear Polarization (Corrosion Measurement), Chronopotentiometry, Galvanostatic Charge-Discharge
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .